Search results for "PHOTON"
showing 10 items of 3171 documents
Fitness, body composition and blood lipids following 3 concurrent strength and endurance training modes
2016
This study investigated changes in physical fitness, body composition, and blood lipid profile following 24 weeks of 3 volume-equated concurrent strength and endurance training protocols. Physically active, healthy male and female participants (aged 18–40 years) performed strength and endurance sessions on different days (DD; men, n = 21; women, n = 18) or in the same session with endurance preceding strength (ES; men, n = 16; women, n = 15) or vice versa (SE; men, n = 18; women, n = 14). The training volume was matched in all groups. Maximal leg press strength (1-repetition maximum (1RM)) and endurance performance (maximal oxygen consumption during cycling), body composition (dual-energy X…
Standing up from a chair as a dynamic equilibrium task: a comparison between young and elderly subjects.
2000
The purpose of this study was to analyze and compare the features of center of mass (CoM) control along anterior/posterior axis in young and elderly subjects during sit-to-stand (STS). From a sitting position, seven healthy young subjects and seven healthy elderly subjects were asked to stand up from a chair under different experimental conditions (visual conditions: normal and blindfolded; speed: normal and as fast as possible). Analysis of results was based upon the concept of a “dynamic equilibrium area” (DEA), which in turn identified the dynamic limits of balance. The results showed that both the maximal CoM velocity in the horizontal axis and the CoM velocity at the instant of seat-of…
Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.
2013
PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …
[123I]IBZM SPECT in patients treated with typical and atypical neuroleptics: relationship to drug plasma levels and extrapyramidal side effects
1997
[123I]Iodobenzamide (IBZM) is an iodine-labeled dopamine receptor ligand and can be used to visualize brain D2 receptors in humans with single photon emission computerized tomography (SPECT). The ratio of striatal IBZM uptake to uptake in frontal cortex (ST/FC ratio) represents a semiquantitative measure of D2 receptor binding in the striatum. Our study sample included six patients treated with haloperidol (3.0-8.0 mg/day orally; one patient with an average of 0.9 mg/day intramuscularly), five patients with benperidol (9.0-15.0 mg/day orally) and nine patients treated with clozapine (200.0-600.0 mg/day orally). Typical neuroleptics (TNs) and atypical neuroleptics (ANs) were significantly di…
Parametric assessment of myocardial perfusion during interventional cardiac catheterization by means of X-ray densitometry-short-and long-term result…
1990
X-ray densitometric evaluation of digital subtraction angiocardiograms allows an assessment of myocardial perfusion by means of the parameter 'MEAN RISE TIME' (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximum opacification. Best results are obtained when the response of that parameter is compared before and after stimulation of coronary flow by papaverine. A prolongation of this parameter, especially after papaverine, was indicative of an impairment of myocardial perfusion, when compared to the results of TL-201 scintigraphy. In 50 patients with single vessel coronary artery disease the results of MRT pre and post papaverine …
Reproducibility of Regional DEXA Examinations of Abdominal Fat and Lean Tissue
2013
<b><i>Objective: </i></b>The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations<i>. </i><b><i>Methods: </i></b>37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. <b><i>Results: </i></b>The mean LM of the abdo…
Dissociation of emotional processes in response to visual and olfactory stimuli following frontotemporal damage.
2005
Contemporary neuropsychological studies have stressed the widely distributed and multicomponential nature of human affective processes. Here, we examined facial electromyographic (EMG) (zygomaticus and corrugator muscle activity), autonomic (skin conductance and heart rate) and subjective measures of affective valence and arousal in patient TG, a 30 year-old man with left anterior mediotemporal and left orbitofrontal lesions resulting from a traumatic brain injury. Both TG and a normal control group were exposed to hedonically valenced visual and olfactory stimuli. In contrast with control subjects, facial EMG and electrodermal activity in TG did not differentiate among pleasant, unpleasant…
Assessing body composition with DXA and bioimpedance: effects of obesity, physical activity, and age.
2008
Objective: This study evaluated to what extent dual-energy X-ray absorptiometry (DXA) and two types of bioimpedance analysis (BIA) yield similar results for body fat mass (FM) in men and women with different levels of obesity and physical activity (PA). Methods and Procedures: The study population consisted of 37–81-year-old Finnish people (82 men and 86 women). FM% was estimated using DXA (GE Lunar Prodigy) and two BIA devices (InBody (720) and Tanita BC 418 MA). Subjects were divided into normal, overweight, and obese groups on the basis of clinical cutoff points of BMI, and into low PA (LPA) and high PA (HPA) groups. Agreement between the devices was calculated by using the Bland–Altman …
Automatic detection and quantification of ground-glass opacities on high-resolution CT using multiple neural networks: comparison with a density mask.
2000
We compared multiple neural networks with a density mask for the automatic detection and quantification of ground-glass opacities on high-resolution CT under clinical conditions.Eighty-four patients (54 men and 30 women; age range, 18-82 years; mean age, 49 years) with a total of 99 consecutive high-resolution CT scans were enrolled in the study. The neural network was designed to detect ground-glass opacities with high sensitivity and to omit air-tissue interfaces to increase specificity. The results of the neural network were compared with those of a density mask (thresholds, -750/-300 H), with a radiologist serving as the gold standard.The neural network classified 6% of the total lung a…
Fitness and lean mass increases during combined training independent of loading order.
2014
Although the benefits of combined endurance (E) and strength (S) training for the development of physical fitness and health are well known, scientific examination of the effect of loading order when E and S are combined into the same training session (E+S vs S+E) is rare. This study investigated the effects of moderate frequency E+S versus S+E training on physical fitness, body composition, and blood lipids.Physically active and healthy young men performed E+S (n = 16) or S+E (n = 18) training 2-3 times a week for 24 wk. Endurance (by incremental bike test) and strength (by dynamic leg press) performance as well as body composition (by dual-energy x-ray absorptiometry), muscle cross-sectio…