Search results for "PHOTONS"
showing 10 items of 164 documents
Study of radiative bottomonium transitions using converted photons
2011
We use 111+/-1 million Upsilon(3S) and 89+/-1 million Upsilon(2S) events recorded by the BaBar detector at the PEP-II B-factory at SLAC to perform a study of radiative transitions between bottomonium states using photons that have been converted to e+e- pairs by the detector material. We observe Upsilon(3S) -> gamma chi_b0,2(1P) decay, make precise measurements of the branching fractions for chi_b1,2(1P,2P) -> gamma Upsilon(1S) and chi_b1,2(2P) -> gamma Upsilon(2S) decays, and search for radiative decay to the eta_b(1S) and eta_b(2S) states.
Detection of charged pions and protons in the segmented electromagnetic calorimeter TAPS
1998
We present the characteristics of the segmented BaF2 calorimeter TAPS for the measurement of charged pions and protons. The method of particle identification exploits the relation between the kinetic energy of a particle, its mass and the time-of-flight required to reach the detector. The detection efficiency is calculated using GEANT-GCALOR simulations. The analysis method is applied in the reaction Ar-40 + Ca-nat at 0.8A GeV. The simultaneous detection of charged pions and protons can be used to search for correlated pairs signalling the de-excitation of the Delta(1232) resonance. (C) 1998 Elsevier Science B.V. All rights reserved.
Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield
2020
[EN] High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have m…
Characterization of a cylindrical plastic {\beta}-detector with Monte Carlo simulations of optical photons
2017
V. Guadilla et al. -- 5 pags., 8 figs., tab.
Correlation between ferrous ammonium sulfate concentration, sensitivity and stability of Fricke gel dosimeters exposed to clinical X-ray beams
2014
Abstract This work describes the characterization of various Fricke-Agarose-Xylenol gels (FXG) dosimeters using NMR relaxometry and MRI analysis. Using X-rays from a clinical linear accelerator (LINAC), the gels were irradiated in the dose range from 0 Gy to 20 Gy. The photon sensitivity of the FXGs was measured in terms of NMR relaxation rates; its dependence on radiation dose was determined as a function of ferrous ammonium sulfate contents (from 0.5 mM to 5 mM). Furthermore, the stability of the NMR signal was monitored over several days after irradiation. These measurements were aided by Magnetic Resonance Imaging (MRI) scans which allowed three-dimensional (3D) dose mapping. In order t…
Analysis of spatial diffusion of ferric ions in PVA-GTA gel dosimeters through magnetic resonance imaging
2017
Abstract This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GTA gel dosimeters. PVA-GTA gel samples, partly exposed with 6 MV X-rays in order to create an initial steep gradient, were mapped using magnetic resonance imaging on a 7T MRI scanner for small animals. Multiple images of the gels were acquired over several hours after irradiation and were analyzed to quantitatively extract the signal profile. The spatial resolution achieved is 200 μm and this makes this technique particularly suitable for the analysis of steep gradients of ferric ion concentration. The results obtained with PVA-GTA gels were compared with those achieved with agarose gels, which …
Analysis of the Photoneutron Field Near the THz Dump of the CLEAR Accelerator at CERN With SEU Measurements and Simulations
2022
We study the radiation environment near the terahertz (THz) dump of the CERN Linear Electron Accelerator for Research (CLEAR) electron accelerator at CERN, using FLUktuierende KAskade in German (FLUKA) simulations and single-event upset (SEU) measurements taken with 32-Mbit Integrated Silicon Solution Inc. (ISSI) static random access memories (SRAMs). The main focus is on the characterization of the neutron field to evaluate its suitability for radiation tests of electronics in comparison with other irradiation facilities. Neutrons at CLEAR are produced via photonuclear reactions, mostly initiated by photons from the electromagnetic cascades that occur when the beam is absorbed by the dump …
Self-sustained coherent phonon generation in optomechanical cavities
2016
Optical forces can set tiny objects in states of mechanical self-sustained oscillation, spontaneously generating periodic signals by extracting power from steady sources. Miniaturized self-sustained coherent phonon sources are interesting for applications such as mass-force sensing, intra-chip metrology and intra-chip time-keeping among others. In this paper, we review several mechanisms and techniques that can drive a mechanical mode into the lasing regime by exploiting the radiation pressure force in optomechanical cavities, namely stimulated emission, dynamical back-action, forward stimulated Brillouin scattering and self-pulsing.
Efficient deep-red light-emitting electrochemical cells based on a perylenediimide-iridium-complex dyad
2009
A two-layer light-emitting electrochemical cell device based on a new perylenediimide-iridium-complex dyad is presented emitting in the deep-red region with high external quantum efficiencies (3.27%). Costa Riquelme, Ruben Dario, Ruben.Costa@uv.es ; Orti Guillen, Enrique, Enrique.Orti@uv.es ; Bolink, Henk, Henk.Bolink@uv.es ; Gierschner, Johannes, Johannes.Gierschner@uv.es
"Table 31" of "Measurements of Higgs boson properties in the diphoton decay channel with 36 fb$^{-1}$ of $pp$ collision data at $\sqrt{s} = 13$ TeV w…
2019
observed statistical correlations between pTyy, Njets, mjj, |DeltaPhijj| and pTj1