Search results for "PLASMA"

showing 10 items of 4043 documents

Excitation modes for fourier transform-ion cyclotron resonance mass spectrometry.

1992

AbstractVarious geometric configurations for the excitation of coherent ion motion in Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR/MS) are analyzed (in some cases for the first time) with unified notation. The instantaneous power absorption, F·v, in which v is ion velocity and F the force produced by the applied excitation electric field (harmonic, single frequency, on-resonance, in-phase), is time averaged and then set equal to the time rate of change of ion total (cyclotron + magnetron + trapping) energy, to yield a differential equation that is readily solved for the (time-dependent) amplitude of each of the various ion motions. The standard FT-ICR excitation (name…

ChemistryCyclotronAnalytical chemistryCyclotron resonanceMass spectrometryFourier transform ion cyclotron resonanceIonlaw.inventionAmplitudeStructural BiologylawPhysics::Plasma PhysicsAtomic physicsSpectroscopyIon cyclotron resonanceExcitationJournal of the American Society for Mass Spectrometry
researchProduct

The elliptical Penning trap: Experimental investigations and simulations

2008

Abstract The application of an additional azimuthal quadrupolar electrostatic field to a Penning trap leads to a field configuration referred to as an elliptical Penning trap. The resulting changes of the radial ion motions have been investigated experimentally and by use of simulations. The eigenfrequencies, i.e., the magnetron frequency ω ˜ − and the reduced cyclotron frequency ω ˜ + , are found to be shifted with respect to those of the standard Penning trap ω − , ω + , respectively. As the shift of the magnetron frequency ω ˜ − is larger than that of the reduced cyclotron frequency ω ˜ + their sum ω ˜ + + ω ˜ − is also a function of the ellipticity and no longer equal to the cyclotron f…

ChemistryCyclotronCyclotron resonanceCondensed Matter PhysicsPenning trapFourier transform ion cyclotron resonancelaw.inventionIonPhysics::Plasma PhysicslawIon trapPhysical and Theoretical ChemistryQuadrupole ion trapAtomic physicsInstrumentationSpectroscopyIon cyclotron resonance
researchProduct

Damping effects in Penning trap mass spectrometry

2011

Abstract Collisions of ions with residual gas atoms in a Penning trap can have a strong influence on the trajectories of the ions, depending on the atom species and the gas pressure. We report on investigations of damping effects in time-of-flight ion-cyclotron resonance mass spectrometry with the Penning trap mass spectrometers ISOLTRAP at ISOLDE/CERN (Geneva, Switzerland) and SHIPTRAP at GSI (Darmstadt, Germany). The work focuses on the interconversion of the magnetron and cyclotron motional modes, in particular the modification of the resonance profiles for quadrupolar excitation due to the damping effect of the residual gas. Extensive experiments have been performed with standard and Ra…

ChemistryCyclotronResonanceCondensed Matter PhysicsMass spectrometryPenning trapISOLTRAPFourier transform ion cyclotron resonancelaw.inventionPhysics::Plasma PhysicslawPhysics::Atomic PhysicsIon trapPhysical and Theoretical ChemistryAtomic physicsNuclear ExperimentInstrumentationSpectroscopyIon cyclotron resonanceInternational Journal of Mass Spectrometry
researchProduct

Zur Plasmaproteinbindung von Arzneimitteln

1969

1. Auf Dialyse, Ultrazentrifugation und Sephadexgelfiltration als die gebrauchlichsten Methoden zur quantitativen Bestimmung der Eiweisbindung von Pharmaka wird hingewiesen. 2. Die Wechselwirkung von niedermolekularen Substanzen mit Proteinen folgt dem Massenwirkungsgesetz. Darauf beruht die Formulierung der Ergebnisse von Eiweisbindungsversuchen. Die Darstellung der Ergebnisse nach Scatchard (1949) wird als die wichtigste Methode angesehen. Daneben sind Darstellungsmethoden nach Scholtan (1962) und Kruger-Thiemer (1961) gebrauchlich, die fur bestimmte Fragestellungen Vorteile bieten. 3. Die Bindung von Pharmaka an Plasmaproteine scheint vorwiegend hydrophoben Charakter zu besitzen. Dabei s…

ChemistryDrug DiscoveryMolecular MedicineGeneral MedicinePlasma protein bindingMolecular biologyGenetics (clinical)Klinische Wochenschrift
researchProduct

Energy distribution of plasma-assisted electron and ion emission from TGS single crystals

2008

Abstract Electron and ion emission accompanying non-thermal plasma processes, produced at the surface of TGS single crystals under driving ac electric field exceeding 10 3  V/cm, have been carried out. These plasma-assisted emission of electrons and ions were examined by means of time and energy distribution measurements. The intensity of registered charges (electrons and ions) displayed on the 2 ms time scale are represented by two distinct peaks. Time dependent energy spectrum of charges, detected under our experimental conditions, involves electrons and ions with maximum energy up to 30–40 eV for first peaks and up to 70–80 eV for second one. Additionally, the energy of electrons is focu…

ChemistryGeneral Physics and AstronomySurfaces and InterfacesGeneral ChemistryElectronPlasmaCondensed Matter PhysicsElectric chargeTriglycine sulfateSurfaces Coatings and FilmsIonIntensity (physics)chemistry.chemical_compoundElectric fieldAtomic physicsEnergy (signal processing)Applied Surface Science
researchProduct

Determination of mineral and trace element concentrations in pine needles by ICP-OES: evaluation of different sample pre-treatment methods

2008

In the present study, the determination of mineral and trace elements (Al, B, Ca, Cu, Fe, K, Mg, Mn, Na, P and Zn) from pine needles using three sample pre-treatment methods followed by inductively coupled plasma optical emission spectrometry, was examined. Sample pre-treatment methods tested were microwave digestion, ultrasound-assisted digestion and dry ashing. The new ultrasound-assisted digestion method was optimised by the analysis of the standard reference material (SRM) 1575a (pine needles) sample. The speed of dry ashing method was significantly increased by ultrasound dissolution after ashing. All the ICP-OES measurements were performed in robust plasma conditions which were tested…

ChemistryHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthAnalytical chemistryTrace elementSoil SciencePollutionAnalytical ChemistryDigestion (alchemy)AshingInductively coupled plasma atomic emission spectroscopyEnvironmental ChemistryMicrowave digestionInductively coupled plasmaWaste Management and DisposalDissolutionMicrowaveWater Science and TechnologyInternational Journal of Environmental Analytical Chemistry
researchProduct

Direct determination of minerals in human diets by infrared spectroscopy and X-ray fluorescence

2014

The use of near and mid infrared spectroscopy and X-ray fluorescence (XRF) to determine the concentration of mineral elements in Spanish human diets was investigated. Thirty-five commercial baby foods, 6 children fast food menus and 13 university canteen menu samples were analysed by infrared and XRF spectroscopy and spectra evaluated by using reference data obtained by inductively coupled plasma optical emission spectroscopy (ICP-OES). Models for calcium, potassium, iron, magnesium, sodium and zinc determination were built and validated. Spectra were pre-treated by using different pre-processing algorithms (multiplicative scatter correction, standard normal variation, first derivate, ortho…

ChemistryInfraredPotassiumPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopychemistry.chemical_elementX-ray fluorescenceInductively coupled plasmaSpectroscopySpectroscopyAnalytical ChemistryMicrochemical Journal
researchProduct

Aggregation versus Biological Activity in Gold(I) Complexes. An Unexplored Concept

2021

The aggregation process of a series of mono- and dinuclear gold(I) complexes containing a 4-ethynylaniline ligand and a phosphane at the second coordination position (PR3-Au-C≡CC6H4-NH2, complexes 1-5, and (diphos)(Au-C≡CC6H4-NH2)2, complexes 6-8), whose biological activity was previously studied by us, has been carefully analyzed through absorption, emission, and NMR spectroscopy, together with dynamic light scattering and small-angle X-ray scattering. These experiments allow us to retrieve information about how the compounds enter the cells. It was observed that all compounds present aggregation in fresh solutions, before biological treatment, and thus they must be entering the cells as a…

ChemistryLigandScatteringBiological activityOrNuclear magnetic resonance spectroscopyAggregation (Chemistry)Inorganic ChemistryCrystallographyDynamic light scatteringAgregació (Química)X-raysRaigs XGoldPhysical and Theoretical ChemistryAbsorption (chemistry)Inductively coupled plasmaCytoskeletonCytoskeleton
researchProduct

Community effects allow bioelectrical reprogramming of cell membrane potentials in multicellular aggregates: Model simulations.

2020

Bioelectrical patterns are established by spatiotemporal correlations of cell membrane potentials at the multicellular level, being crucial to development, regeneration, and tumorigenesis. We have conducted multicellular simulations on bioelectrical community effects and intercellular coupling in multicellular aggregates. The simulations aim at establishing under which conditions a local heterogeneity consisting of a small patch of cells can be stabilized against a large aggregate of surrounding identical cells which are in a different bioelectrical state. In this way, instructive bioelectrical information can be persistently encoded in spatiotemporal patterns of separated domains with diff…

ChemistryNormal tissueGap Junctions01 natural sciencesModels BiologicalIon Channels010305 fluids & plasmasElectrophysiological PhenomenaMembrane PotentialsCell membraneCoupling (electronics)Multicellular organismmedicine.anatomical_structure0103 physical sciencesCell polarityBiophysicsmedicine010306 general physicsIntercellular couplingReprogrammingIon channelCell AggregationSignal TransductionPhysical review. E
researchProduct

Precision experiments on exotic nuclei at IGISOL

2006

Abstract Cooling and trapping techniques of low-energy radioactive ion beams of refractory elements employed at the IGISOL facility are presented with emphasis on high-precision measurements of the ground state properties of exotic nuclei. The impact of the new generation Paul and Penning traps on mass measurements of short-lived nuclei is discussed with examples on precision measurements of masses of super-allowed beta emitters and neutron-rich nuclei. As a new concept the trap-assisted spectroscopy of radioactive ions is presented with applications in collinear laser spectroscopy, decay spectroscopy of isobarically purified sources and in nuclear cross-section measurements by ion counting.

ChemistryNuclear TheoryRefractory metalsTrappingCondensed Matter PhysicsPenning trapAtomic massIonBeta (plasma physics)Physics::Atomic PhysicsPhysical and Theoretical ChemistryAtomic physicsNuclear ExperimentGround stateSpectroscopyInstrumentationSpectroscopyInternational Journal of Mass Spectrometry
researchProduct