Search results for "PLASMA"
showing 10 items of 4043 documents
Accurate determination of element species by on-line coupling of chromatographic systems with ICP-MS using isotope dilution technique
1998
Abstract The instrumental design for coupling different liquid chromatographic systems such as ion, reversed phase, and size exclusion chromatography as well as capillary gas chromatography, with ICP-MS for the determination of element species is described. For accurate analyses obtaining ‘real time’ concentrations of chromatographic peaks, the isotope dilution mass spectrometric (IDMS) technique is applied. Two different spiking modes are possible, one using species-specific and another one using species-unspecific spike solutions of isotope-enriched labelled compounds. The species-specific mode is only possible for element species well defined in their structure and composition, for examp…
Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?
2003
This critical review discusses the conditions under which inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) is suitable as a routine method for trace element and element-speciation analysis. It can, in general, be concluded that ICP-IDMS has high potential for routine analysis of trace elements if the accuracy of results is of predominant analytical importance. Hyphenated techniques with ICP-IDMS suffer both from lack of commercially available isotope-labeled spike compounds for species-specific isotope dilution and from the more complicated system set-up required for species-unspecific ICP-IDMS analysis. Coupling of gas or liquid chromatography with species-specific …
ICP-MS multielement determination in fly ash after microwave-assisted digestion of samples.
2001
A microwave assisted digestion procedure has been developed for dissolution of fly ash samples prior to the inductively coupled plasma-mass spectrometric determination of their elemental composition. The developed methodology was validated by carrying out the analysis of two high-silicate containing reference materials (CRM 134R sewage amended soil and NIES JR 1 rock) and by means of the comparison between results found by microwave-assisted digestion and ICP-MS of fly ash samples with those found by neutron activation analysis (NAA) for Sb, Cs, Cr, Co, Fe, U and Zn determination. The method developed can be recommended for routine multielement analysis of fly ash.
An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical em…
2007
Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min−1, auxiliary gas flow of 0.2 L min−1 and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-ass…
Die Elimination von Hydroxyäthylstärke 200/0,5, Dextran 40 und Oxypolygelatine
1982
After withdrawal of 400 ml whole blood and subsequent infusion of 500 ml of a colloidal plasma substituent, the intravascular and renal colloid elimination was investigated in 40 test subjects. The individual colloidal solutions could no longer be demonstrated in the intravascular space after the following times: 10% hydroxyethyl starch 200/0.5 (anthrone method) after six weeks, 10% dextran 40 (anthrone method) after two weeks, 6% hydroxyethyl starch 200/0.5 (anthrone method) after four weeks and 5.5% oxypolygelatine (hydroxyproline method) after two days. Colloidal plasma substitutes are polydisperse solutions with various molecular weights and degree of hydroxyethylation and therefore, al…
Characterization of antihistamine–human serum protein interactions by capillary electrophoresis
2007
An important topic in the drug discovery and development process is the role of drug binding to plasma proteins. In this paper the characterization of the interaction between antihistamines (cationic drugs) towards human serum albumin (HSA) and alpha(1)-acid glycoprotein (AGP) under physiological conditions by capillary electrophoresis-frontal analysis is presented. Furthermore, the binding of these drugs to all plasma proteins is evaluated by using ultrafiltration and capillary electrophoresis. Antihistamines present a wide-ranging behaviour with respect to their affinities towards plasma proteins. Orphenadrine, phenindamine, tripelenamine and tripolidine principally bind to HSA; carbinoxa…
Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.
2014
Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method d…
Determination of benperidol and its reduced metabolite in human plasma by high-performance liquid chromatography and electrochemical detection.
1991
An isocratic high-performance liquid chromatographic method with electrochemical detection for the quantification of benperidol and its suggested reduced metabolite TVX Q 5402 in human plasma is described. The method included a two-step solid-phase extraction on reversed-phase and cation-exchange material, followed by separation on a cyanopropyl silica gel column (5 microns; 250 mm x 4.6 mm I.D.). The eluent was 0.15 M acetate buffer (pH 4.7) containing 25% acetonitrile (w/w). Spiperone served as internal standard. The inclusion of the cation-exchange step provided sample purity higher than those achieved with other methods. After extraction of 1 ml of plasma, concentrations as low as 0.5 n…
Peptides analysis in blood plasma using on-line system of supported liquid membrane and high-performance liquid chromatography
2005
The potential of using supported liquid membrane (SLM) technique, combined with reversed-phase high-performance liquid chromatography (RP-HPLC) has been investigated for the determination of peptides in human blood plasma. The peptides studied were (DL)Leu(DL)Phe, MetLeuPhe, GlyLeuTyr and ValGluProlleProTyr. The carrier (Aliquat 336) was incorporated in membrane phase in order to facilitate the transport of investigated peptides. After extraction, the analyte-enriched acceptor phase was directly injected into an HPLC system for analysis. With SLM, high selectivity and efficiency were achieved for extraction of peptides in aqueous solutions. Lower extraction efficiency was obtained in plasma…
Development of a species-unspecific isotope dilution GC-ICPMS method for possible routine quantification of sulfur species in petroleum products.
2008
Inductively coupled plasma mass spectrometry (ICPMS) hyphenated with capillary gas chromatography was applied for sulfur multispecies determination in petroleum products by species-unspecific isotope dilution mass spectrometry (IDMS). To guarantee a stable and continuous addition of the spike into the GC-ICPMS system, a special dosing unit was designed and synthesis of a (34)S-labeled dimethyldisulfide spike from (34)S-enriched elemental sulfur in the milligram range was developed. The sample was mixed with an internal standard for spike mass flow calibration. From the mass flow chromatogram obtained by species-unspecific GC-ICP-IDMS, determination of all separated sulfur species and of the…