Search results for "PLASMA"

showing 10 items of 4043 documents

Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser …

2003

Four alternative analytical procedures for the determination of ten important trace impurities (Mg, Cr, Fe, Cu, Zn, Sr, Zr, Cd, Ba, and Pb) in pure alkaline earth fluoride powders were applied using high-resolution inductively coupled plasma mass spectrometry (ICP-MS). Two procedures are based on a wet-chemical microwave digestion with boric acid and quantification by the standard addition technique and isotope dilution mass spectrometry (IDMS), respectively. In addition, analyses are also performed by laser ablation as a direct solid sampling technique applying matrix-matched external calibration as well as isotope dilution of the powdered sample. For most elements good agreement between t…

Detection limitLaser ablationChemistryStandard additionAnalytical chemistryAnalytical proceduresSample preparationIsotope dilutionMicrowave digestionBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryAnalytical and bioanalytical chemistry
researchProduct

Development of an isotope dilution laser ablation ICP-MS method for multi-element determination in crude and fuel oil samples

2009

An inductively coupled plasma isotope dilution mass spectrometric (ICP-IDMS) method with direct introduction of the isotope-diluted sample into the plasma by laser ablation was developed for accurate, sensitive, fast, and simultaneous determination of trace metals in different oil samples. Metallo-organic solutions of isotope spikes (50V, 53Cr, 65Cu, 57Fe, 62Ni, 68Zn, 113Cd, 117Sn, and 206Pb) were prepared from corresponding aqueous stock solutions by using liquid–liquid extraction of complexed metal ions in isobutyl methyl ketone. The isotope-diluted sample was absorbed by a cellulose material, which was fixed in a special PTFE holder for ablation, using a laser system with high ablation r…

Detection limitLaser ablationChromatographyChemistryAnalytical chemistryVanadiumchemistry.chemical_elementFuel oilFractionationIsotope dilutionAnalytical ChemistryInductively coupled plasmaInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Validating quantitative PCR assays for cell-free DNA detection without DNA extraction: Exercise induced kinetics in systemic lupus erythematosus pati…

2021

ABSTRACTCirculating cell-free DNA (cfDNA) has been investigated as a screening tool for many diseases. To avoid expensive and time-consuming DNA isolation, direct quantification PCR assays can be established. However, rigorous validation is required to provide reliable data in the clinical and non-clinical context. Considering International Organization for Standardization, as well as bioanalytical method validation guidelines we provide a comprehensive procedure to validate assays for cfDNA quantification from unpurified blood plasma. A 90 and 222 bp assay was validated to study the kinetics of cfDNA after exercise in patients with systemic lupus erythematosus. The assays showed ultra-low …

Detection limitOncologymedicine.medical_specialtyBioanalysisbusiness.industryContext (language use)RepeatabilityDNA extractionReal-time polymerase chain reactionCell-free fetal DNAInternal medicineBlood plasmamedicinebusiness
researchProduct

Determination of phytic acid and its degradation products by ion-pair chromatography (IPC) coupled to inductively coupled plasma-sector field-mass sp…

2004

We developed a method for the determination of phytic acid (IP6) and its degradation products (IP1-IP5) by ion-pair chromatography coupled to a double focussing inductively coupled plasma-sector field-mass spectrometer (ICP-SF-MS). For the detection of the phosphorus species a mass resolution (m/Δm) of 4000 was needed in order to separate the 31P+ signal from the interfering clusterions. The separation of the six phosphorus species was enabled by a gradient elution using tetrabutylammonium hydroxide (TBA) as ion-pair reagent. Calibration data were reported and a detection limit of 230 ng g−1 for IP6 could be obtained. The method was firstly proved for a hydrolyzate of commercially available…

Detection limitPhytic acidChromatographyTetrabutylammonium hydroxidePhosphorusfood and beverageschemistry.chemical_elementMass spectrometryAnalytical Chemistrychemistry.chemical_compoundchemistryReagentInositolInductively coupled plasmaSpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Simultaneous determinations of zirconium, hafnium, yttrium and lanthanides in seawater according to a co-precipitation technique onto iron-hydroxide.

2013

Very low concentrations (pg mL(-1) or sub-pg mL(-1) level) along with the high salinity are the main problems in determining trace metal contents in seawater. This problem is mainly considered for investigations of naturally occurring YLOID (Y and Lanthanides) and Zr and Hf in order to provide precise and accurate results. The inductively coupled plasma mass spectrometry (ICP-MS), both in high and low resolution, offers many advantages including simultaneous analyses of all elements and their quantitative determination with detection limits of the order of pg mL(-1). However in the analysis of YLOID in seawater, a better determination needs an efficient combination of ICP-MS measurement wit…

Detection limitQuality ControlZirconiumSpectrophotometry AtomicAnalytical chemistrychemistry.chemical_elementFlocculationYttriumFerric CompoundsLanthanoid Series ElementsAnalytical ChemistryWorking rangeHafniumTrace ElementsCertified reference materialschemistryLimit of DetectionSeawaterSeawaterYttriumZirconiumInductively coupled plasma mass spectrometryHafniumTalanta
researchProduct

Application of stable isotopes and AF4/ICP-SFMS for simultaneous tracing and quantification of iron oxide nanoparticles in a sediment–slurry matrix

2016

One major challenge in nanomaterial analysis, especially in complex environmental matrices, is the unambiguous differentiation between natural and engineered nanomaterials (ENMs). Particularly with regard to the investigation of ENM's/engineered nanoparticle's (ENPs) fate, analytical methods are needed allowing for tracing and sensitive quantification. Several ENPs are metal-based and contain elements being omnipresent in environmental matrices (e.g., Al, Ti, Zn, Fe and non-metal Si) – hence, high background levels of these elements are expected, compromising sensitive detection. In this work we developed successfully a combined approach of stable isotope labeling (tracing) and reverse post…

Detection limitStable isotope ratioElution010401 analytical chemistryRadiochemistryAnalytical chemistry010501 environmental sciencesIsotope dilution01 natural sciencesSilver nanoparticle0104 chemical sciencesAnalytical Chemistrychemistry.chemical_compoundColloidchemistryInductively coupled plasma mass spectrometrySpectroscopyIron oxide nanoparticles0105 earth and related environmental sciencesJournal of Analytical Atomic Spectrometry
researchProduct

Determination of arsenic compounds in beverages by high-performance liquid chromatography-inductively coupled plasma mass spectrometry.

2005

Arsenic compounds including arsenous acid (As(III)), arsenic acid (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were separated by high-performance liquid chromatography (HPLC) and detected by inductively coupled plasma mass spectrometry (ICP-MS). A Hamilton PRX-100 anionic-exchange column and a pH 8.5 K(2)HPO(4)/KH(2)PO(4) 5.0x10(-3)molL(-1) mobile phase were used to achieve arsenic speciation. The separation of arsenic species provided peaks of As(III) at 2.75min, DMA at 3.33min, MMA at 5.17min and As(V) at 12.5min. The detection limits, defined as three times the standard deviation of the lowest standard measurements, were found to be 0.2, 0.2, 0.3 and 0.5ngmL(-1) f…

Detection limitchemistry.chemical_compoundChromatographyCertified reference materialsChemistryArsenous acidchemistry.chemical_elementArsenic CompoundHigh-performance liquid chromatographyArsenic acidInductively coupled plasma mass spectrometryArsenicAnalytical ChemistryTalanta
researchProduct

Active alkaline traps to determine acidic-gas ratios in volcanic plumes: Sampling techniques and analytical methods

2014

In situ measurements have been the basis for monitoring volcanic gas emissions for many years and—being complemented by remote sensing techniques—still play an important role to date. Con- cerning in situ techniques for sampling a dilute plume, an increase in accuracy and a reduction of detection limits are still necessary for most gases (e.g., CO2, SO2, HCl, HF, HBr, HI). In this work, the Raschig-Tube tech- nique (RT) is modified and utilized for application on volcanic plumes. The theoretical and experimental absorption properties of the RT and the Drechsel bottle (DB) setups are characterized and both are applied simultaneously to the well-established Filter packs technique (FP) in the …

Detection limitgeographyAnalytegeography.geographical_feature_categoryalkaline traps plume sampling sulfur and halogen Etna volcanoDifferential optical absorption spectroscopyIon chromatographyMineralogySettore GEO/08 - Geochimica E VulcanologiaPlumeGeophysicsVolcanoGeochemistry and PetrologyAbsorption (electromagnetic radiation)Inductively coupled plasma mass spectrometryGeologyGeochemistry, Geophysics, Geosystems
researchProduct

Development and Optimization of Pre-Concentration Procedure of Rare-Earth Elements (REEs) in Their Minerals, Using Microwave - Assisted Sample Dissol…

2015

Abstract The aim of this research was to develop and optimize a procedure for determination of REEs in xenotime and monazite samples collected from Bangka Island, which were compared to Standard Monazite (71 AG) of Bureau of Analyzed Samples, London. ICP-OES method was used for the determination. The samples were dried and sterilized by heating for a week at 110 °C, before digesting with nitric acid and hydrofluoric acid, using a microwave-assisted digestion system. After a careful line selection, at the detection limits for all REEs in the ng/mL the REEs were reliably obtained at the 0.09 – 38% level.

Detection limitmicrowaveChemistry(all)RadiochemistryAtomic emission spectroscopyAnalytical chemistryGeneral Medicinechemistry.chemical_compoundREEsHydrofluoric acidpre-concentrationchemistryNitric acidMonaziteInductively coupled plasma atomic emission spectroscopymonaziteICP-OESChemical Engineering(all)Pre concentrationDissolutionxenotimeProcedia Chemistry
researchProduct

Development of a specific assay using RISA for detection of the bacterial agent of 'basses richesses' syndrome of sugar beet and confirmation of a Pe…

2007

International audience; A technique for the specific diagnosis in insects of SBRp (the γ-3 proteobacterium associated with the syndrome ‘basses richesses’ (SBR) of sugar beet crops in eastern France), using the RISA (rDNA intergenic spacer analysis) technique, was developed. PCR using the Alb1/Oliv1 primer pair specifically amplified a 16S-ITS region of SBRp and produced a characteristic DNA fingerprint. This PCR assay did not detect other closely related organisms, including the Arsenophonus endosymbiont of Diaphorina citri, the secondary endosymbiont of Glycaspis brimblecombei, or ‘Candidatus Phlomobacter fragariae’, a related phytopathogenic γ-3 proteobacterium. Six different ribosomal o…

Diaphorina citri[SDV]Life Sciences [q-bio]Plant ScienceHorticultureMicrobiologylaw.invention03 medical and health scienceslawGeneticsCicadomorphaPolymerase chain reaction030304 developmental biology0303 health sciencesbiology030306 microbiologyfungiRIBOSOMAL OPERONRibosomal RNAbiology.organism_classificationCixiidaeDNA profilingPhytoplasmaSTOLBUR PHYTOPLASMAPROTEOBACTERIAINSECT VECTORSSugar beetAgronomy and Crop Science
researchProduct