Search results for "POLE"
showing 10 items of 1981 documents
First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas
2014
The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…
Application of ultra-high pressure liquid chromatography linear ion-trap orbitrap to qualitative and quantitative assessment of pesticide residues
2014
Abstract The analysis of pesticides residues using a last generation high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS) was explored. Pesticides were extracted from fruits, fish, bees and sediments by QuEChERS and from water by solid-phase with Oasis HLB cartridges. Ultra-high pressure liquid chromatography (UHPLC)–LTQ-Orbitrap mass spectrometer acquired full scan MS data for quantification, and data dependent (dd) MS 2 and MS 3 product ion spectra for identification and/or confirmation. The regression coefficients ( r 2 ) for the calibration curves (two order of magnitude up to the lowest calibration level) in the study were ≥0.99. Th…
Applicability of hybrid linear ion trap-high resolution mass spectrometry and quadrupole-linear ion trap-mass spectrometry for mycotoxin analysis in …
2012
Abstract Recent developments in mass spectrometers have created a paradoxical situation; different mass spectrometers are available, each of them with their specific strengths and drawbacks. Hybrid instruments try to unify several advantages in one instrument. In this study two of wide-used hybrid instruments were compared: hybrid quadrupole-linear ion trap-mass spectrometry (QTRAP ® ) and the hybrid linear ion trap-high resolution mass spectrometry (LTQ-Orbitrap ® ). Both instruments were applied to detect the presence of 18 selected mycotoxins in baby food. Analytical parameters were validated according to 2002/657/CE. Limits of quantification (LOQs) obtained by QTRAP ® instrument ranged …
Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…
2014
An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…
On the timing properties of SAX J1808.4-3658 during its 2015 outburst
2017
We present a timing analysis of the 2015 outburst of the accreting millisecond X-ray pulsar SAX J1808.4-3658, using non-simultaneous XMM-Newton and NuStar observations. We estimate the pulsar spin frequency and update the system orbital solution. Combining the average spin frequency from the previous observed, we confirm the long-term spin down at an average rate $\dot{\nu}_{\text{SD}}=1.5(2)\times 10^{-15}$ Hz s$^{-1}$. We also discuss possible corrections to the spin down rate accounting for mass accretion onto the compact object when the system is X-ray active. Finally, combining the updated ephemerides with those of the previous outbursts, we find a long-term orbital evolution compatibl…
Ultracold Rare-Earth Magnetic Atoms with an Electric Dipole Moment
2018
We propose a new method to produce an electric and magnetic dipolar gas of ultracold dysprosium atoms. The pair of nearly degenerate energy levels of opposite parity, at 17513.33 cm$^{-1}$ with electronic angular momentum $J=10$, and at 17514.50 cm$^{-1}$ with $J=9$, can be mixed with an external electric field, thus inducing an electric dipole moment in the laboratory frame. For field amplitudes relevant to current-day experiments, we predict a magnetic dipole moment up to 13 Bohr magnetons, and an electric dipole moment up to 0.22 Debye, which is similar to the values obtained for alkali-metal diatomics. When a magnetic field is present, we show that the electric dipole moment is strongly…
Experimental verification of position-dependent angular-momentum selection rules for absorption of twisted light by a bound electron
2018
We analyze the multipole excitation of atoms with twisted light, i.e., by a vortex light field that carries orbital angular momentum. A single trapped $^{40}$Ca$^+$ ion serves as a localized and positioned probe of the exciting field. We drive the $S_{1/2} \to D_{5/2}$ transition and observe the relative strengths of different transitions, depending on the ion's transversal position with respect to the center of the vortex light field. On the other hand, transition amplitudes are calculated for a twisted light field in form of a Bessel beam, a Bessel-Gauss and a Gauss-Laguerre mode. Analyzing experimental obtained transition amplitudes we find agreement with the theoretical predictions at a…
The à 1Au state and the T2 potential surface of acetylene: Implications for triplet perturbations in the fluorescence spectra of the à state
1996
The cis–trans isomerization reaction on the T2 surface of acetylene and the lowest excited singlet state of acetylene, A 1Au, are investigated by ab initio electronic structure theory. We report optimized geometries, dipole moments, and harmonic vibrational frequencies of stationary points and adiabatic energy differences between them using basis sets as large as triple‐ζ plus double polarization with higher angular momentum functions, TZ(2df,2pd), and theoretical methods up to coupled‐cluster singles and doubles with a perturbative triples correction [CCSD(T)] and the equation‐of‐motion coupled‐cluster method (EOM‐CCSD). Our theoretical predictions should aid the interpretation of observat…
Centinela contra judios, puesta en la torre de la Iglesia de Dios / con el trabajo, caudal, y desvelo del Padre Fray Francisco de Torrejoncillo ... d…
1691
Sig. [calderó]8, A-P8
Antonio Belguardo. Un maestro nella Palermo tra XV e XVI secolo: il regesto documentario
2016
Le informazioni documentarie emerse in questi ultimi anni sulla figura di Antonio Belguardo permettono di tracciare con maggiore compiutezza il profilo biografico e la parabola professionale di uno dei più prolifici protagonisti della stagione tardogotica dell’architettura siciliana; la sua attività, per quanto sinora noto, si concentra prevalentemente a Palermo tra l’ultimo quarto del XV secolo e i primi decenni del XVI. New documents that have come to light on Antonio Belguardo allow us to draw a more complete biographic profile of one of the most prolific protagonists of Late Gothic Sicilian architecture; His activity, as far as we know, was mainly carried out in Palermo, between the las…