Search results for "PSU"

showing 10 items of 678 documents

Refractive changes in nuclear, cortical and posterior subcapsular cataracts. Effect of the type and grade

2015

Purpose: To determine the effect of main morphological types and grades of age-related cataracts on refractive error. Methods: We measured 276 subjects with optical compensation prior to the development of cataract. We evaluated 224 eyes with nuclear cataract, 125 with cortical cataract, and 103 with posterior subcapsular (PSC) cataract classified with LOCSIII. We measured visual acuity (VA) with their spectacles and best-corrected visual acuity (BCVA) with chart in decimal scale to obtain the optimal compensation with cataract. We evaluated the differences between compensations. Results: A significant myopic shift was observed in nuclear cataract from low to mild grade (p = 0.031), the sam…

Malemedicine.medical_specialtyRefractive errorNuclear cataractVisual acuitygenetic structuresCortical cataractVisual AcuityCatarataAstigmatismCataractContrast SensitivityCorticallcsh:OphthalmologyCataractsOphthalmologyLens CrystallineOptical compensationMyopiamedicineHumanslcsh:QC350-467Subcapsular posteriorNuclearIn patientCompensación ópticaAgedAged 80 and overAnalysis of Variancebusiness.industryAstigmatismLens Nucleus CrystallineLens Cortex CrystallineMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSurgeryPosterior subcapsularlcsh:RE1-994FemaleOriginal Articlesense organsPosterior subcapsular cataractmedicine.symptombusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Relationship between adherence to the Mediterranean Diet, intracerebral hemorrhage, and its location

2018

INTRODUCTION: Although some authors evaluated the relationship between adherence to the Mediterranean Diet (MeDi) and both ischemic and hemorrhagic stroke, hemorrhagic stroke alone is not yet examined. AIMS: We conducted a retrospective study to evaluate the relationship between adherence to MeDi and intracerebral hemorrhage (ICH) and different locations of ICH (ganglionic/internal capsule, brainstem/cerebellum, or lobar). METHODS: We analyzed charts and collected data of all consecutive patients with ICH admitted to our Internal Medicine Ward from 2005 to 2014. A scale indicating the degree of adherence to the traditional MeDi Score was constructed. RESULTS: When compared with 100 subjects…

Malemedicine.medical_specialtyTime FactorsSettore MED/09 - Medicina InternaInternal capsuleMediterranean dietEndocrinology Diabetes and MetabolismMedicine (miscellaneous)030209 endocrinology & metabolism030204 cardiovascular system & hematologyDiet MediterraneanRisk Assessment03 medical and health sciences0302 clinical medicineRisk FactorsInternal medicinePrevalenceHumansMedicineIn patientcardiovascular diseasesStrokeAgedCerebral HemorrhageRetrospective StudiesAged 80 and overIntracerebral hemorrhageNutrition and DieteticsProteinuriabusiness.industryRetrospective cohort studyMiddle AgedProtective FactorsPrognosismedicine.diseaseItalyMediterranean Diet ICHFemaleDiet Healthymedicine.symptomCardiology and Cardiovascular MedicinebusinessRisk Reduction BehaviorDyslipidemiaNutrition, Metabolism and Cardiovascular Diseases
researchProduct

CT after enucleation of renal cell carcinoma.

1994

Computed tomography (CT) was performed in 28 patients 2 weeks to 120 months after enucleation of renal cell carcinoma. The postoperative defect could be exactly localized in all patients. A wedge-shaped (N = 11) or concave (N = 9) morphology was typical. No dependence between morphology of the defect and localization or size of the tumor or the operative technique was observed. The defects were smaller (1.9 cm) than the original prominent tumors (3.6 cm). Defect size was dependent on the operative technique: closure by suture of the renal capsule in smaller defects or by fat flap in larger ones. Postoperative hematomas or delayed perfusion in the adjacent parenchyma were seen in five patien…

Malemedicine.medical_specialtyUrologyEnucleationDiagnosis DifferentialPostoperative ComplicationsSuture (anatomy)Renal capsuleRenal cell carcinomaParenchymaMedicineHumansRadiology Nuclear Medicine and imagingCarcinoma Renal CellKidneyRadiological and Ultrasound Technologybusiness.industryGastroenterologyKidney NeoplasmMiddle Agedmedicine.diseaseKidney Neoplasmsmedicine.anatomical_structureFemaleRadiologyNeoplasm Recurrence LocalbusinessTomography X-Ray ComputedPerfusionAbdominal imaging
researchProduct

Effect of large positioning holes on capsule fixation of plate-haptic intraocular lenses

2000

Abstract Purpose To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. Setting Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. Methods In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted under standardized conditions by the same surgeon. The IOL position was documented at the end of surgery and by retroillumination on the first day and 5 months postoperatively. The positioning-hole area was evaluated by ultrasound biomicroscopy (50 MHz) 5 months postoperatively. Results One day postoperatively, no IOL in either group was decentered more than 1.0 mm. Aft…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseLens Capsule CrystallineUltrasound biomicroscopyIntraocular lensProsthesis Designlaw.inventionFixation (surgical)Foreign-Body MigrationLens Implantation IntraocularlawOphthalmologyHumansMedicineProspective StudiesCapsulorhexisAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industrySuture TechniquesCapsuleMiddle Agedmedicine.diseaseCapsulorhexiseye diseasesSensory SystemsSurgeryLens (optics)OphthalmologyCapsulotomyFemaleSurgerysense organsbusinessCell DivisionJournal of Cataract and Refractive Surgery
researchProduct

Human taeniasis diagnosed by radiography/endoscopy and morphology

2011

Malemedicine.medical_specialtymedicine.diagnostic_testbusiness.industryRadiographyGastroenterologyTaenia saginatamedicine.diseaseCapsule EndoscopySurgeryEndoscopyAnimalsHumansMedicineTaeniasisRadiology Nuclear Medicine and imagingRadiologyIntestinal Diseases ParasiticbusinessTaeniasisGastrointestinal Endoscopy
researchProduct

Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation

2003

Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…

Malemedicine.medical_specialtymedicine.medical_treatmentAcrylic ResinsLens Capsule CrystallineIntraocular lensPositive correlationCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageLenses IntraocularPhacoemulsificationbusiness.industryCapsulePhacoemulsificationCataract surgeryCapsulorhexisSensory SystemsOphthalmologyCapsular bagFemaleSurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

2005

To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…

Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessJournal of cataract and refractive surgery
researchProduct

Microfluidic Fabrication of Physically Assembled Nanogels and Micrometric Fibers by Using a Hyaluronic Acid Derivative

2017

The employ of a hyaluronic acid (HA) derivative, bearing octadecyl (C18) and ethylenediamine (EDA) groups, for microfluidic fabrication of nanogels and microfibers is reported in this study. Two HA-EDA-C18 derivatives (125 and 320 kDa) having ionic strength sensitive properties are synthesized and characterized. The control of the rheological properties of HA-EDA-C18 aqueous dispersions by formation of inclusion complexes with hydroxypropyl-β-cyclodextrins (HPCD) is described. Reversibility of C18/HPCD complexation and physical crosslinking is detected in media with different ionic strength through oscillation frequency tests. HA-EDA-C18 125 kDa is employed for nanogel fabrication. Control …

Materials Chemistry2506 Metals and AlloysFabricationbusiness.product_categoryMaterials sciencePolymers and PlasticsGeneral Chemical Engineeringmicrofluidic02 engineering and technology010402 general chemistrycell encapsulation01 natural scienceschemistry.chemical_compoundmicrofiberhyaluronic acidMicrofiberHyaluronic acidPolymer chemistryMaterials ChemistrymicrochannelChemical Engineering (all)Cell encapsulationPolymers and PlasticOrganic Chemistrytechnology industry and agriculturefood and beverages021001 nanoscience & nanotechnology0104 chemical sciencesChemical engineeringchemistryIonic strengthnanogelSurface modificationlipids (amino acids peptides and proteins)Adhesive0210 nano-technologybusinessNanogelMacromolecular Materials and Engineering
researchProduct

Mechanical and Structural Tuning of Reversible Hydrogen Bonding in Interlocked Calixarene Nanocapsules

2019

We present force probe molecular dynamics simulations of dimers of interlocked calixarene nanocapsules and study the impact of structural details and solvent properties on the mechanical unfolding pathways. The system consists of two calixarene "cups" that form a catenane structure via interlocked aliphatic loops of tunable length. The dimer shows reversible rebinding, and the kinetics of the system can be understood in terms of a two-state model for shorter loops (≤14 CH2 units) and a three-state model for longer loops (≥15 CH2 units). The various conformational states of the dimer are stabilized by networks of hydrogen bonds, the mechanical susceptibility of which can be altered by changi…

Materials science010304 chemical physicsHydrogen bondDimerCatenaneKinetics010402 general chemistry01 natural sciencesNanocapsules0104 chemical sciencesSurfaces Coatings and FilmsSolventchemistry.chemical_compoundMolecular dynamicschemistryChemical physics0103 physical sciencesCalixareneMaterials ChemistryPhysical and Theoretical ChemistryThe Journal of Physical Chemistry B
researchProduct

Effect of media composition on long-term in vitro stability of barium alginate and polyacrylic acid multilayer microcapsules.

2000

For a number of applications stability of microcapsules is a critical factor. Since the maintenance of polyelectrolyte complexes depends considerably on the ion composition we tested the physical properties of barium alginate capsules and searched for conditions to improve stability by a multilayer coating with polyethylenimine (PEI) and polyacrylic acid (PAA). Mechanical stability and diameters were determined in barium alginate capsules and compared with multilayer capsules. Multilayer coating resulted in smaller capsules than barium complexing alone. The difference was more pronounced when CaCl2 was used instead of NaCl during coating. Barium alginate capsules and application of CaCl2 du…

Materials scienceAlginatesBiophysicsAcrylic Resinschemistry.chemical_elementBioengineeringBiocompatible MaterialsCapsulesengineering.materialPermeabilityBiomaterialschemistry.chemical_compoundCoatingCoated Materials BiocompatibleDrug StabilityPolymer chemistrySodium citratePolyethyleneiminePolyethyleniminePolyacrylic acidCapsuleBariumPolyelectrolyteCulture MediachemistryChemical engineeringDistilled waterMechanics of MaterialsCeramics and CompositesengineeringStress MechanicalBiomaterials
researchProduct