Search results for "PULSE"

showing 10 items of 1508 documents

Safety and feasibility of a neuromuscular electrical stimulation chronaxie-based protocol in critical ill patients: A prospective observational study

2017

International audience; Purpose: The aim of this study was to evaluate the safety and feasibility of a neuromuscular electrical stimulation (NMES) protocol based on neuromuscular excitability and applied in numerous muscle groups of critical ill patients.Materials and methods: We performed a prospective observational study using an NMES applied daily and bilaterally into 5 muscle groups in lower limbs for 3 consecutive days. The characteristics of NMES were 90 contractions per muscle, pulse width equal to chronaxie, and a pulse frequency of 100 Hz. We assessed safety with central venous oxygen saturation, serum lactate, and creatine phosphokinase measurements. To evaluate feasibility, we re…

AdultMalecontractionsmedicine.medical_specialtyChronaxieCritical CareElectric Stimulation TherapyStimulation030204 cardiovascular system & hematologyCritical Care and Intensive Care Medicineknee extensor muscles03 medical and health sciences0302 clinical medicine[ SDV.MHEP ] Life Sciences [q-bio]/Human health and pathologymedicinePulse frequencyHumanscritical illnessskeletal-muscleLactic AcidProspective StudiesvoluntaryMuscle SkeletalAPACHEIntensive care unit-acquired weaknessbiologyacquired weaknessbusiness.industryRehabilitationMuscle weakness030208 emergency & critical care medicinethicknessNeuromuscular stimulationMale patientIntensive careAnesthesiarhabdomyolysisPhysical therapybiology.proteinFemaleObservational studyCreatine kinaseelectromyostimulationSerum lactateSafetystrengthbusinessChronaxyMuscle ContractionJournal of Critical Care
researchProduct

Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques

2008

Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …

AdultMalemedicine.diagnostic_testPhantoms Imagingbusiness.industryImage qualityPerfusion scanningPulse sequenceBlood flowMagnetic Resonance ImagingMyocardial perfusion imagingContrast mediumCoronary CirculationHealthy volunteerscardiovascular systemmedicineImage noiseHumansFemaleRadiology Nuclear Medicine and imagingNuclear medicinebusinessMathematicsJournal of Magnetic Resonance Imaging
researchProduct

Color doppler ultrasonography of soft-tissue masses

1998

Purpose: To evaluate the capability of color Doppler ultrasonography to differentiate between benign and malignant soft-tissue tumors. Material and Methods: We reviewed the ultrasonographic (US) and color Doppler (CD) findings in 46 consecutive patients with a palpable periskeletal mass. The presence of 3 or more vascular hila and of tortuous and irregular internal vessels within the lesions was considered an indication of malignancy. The CD diagnosis was compared with that obtained at US alone. Results: The sensitivity and specificity of CD were respectively 85% and 92%; these values were higher than those obtained at US alone, respectively 75% and 50%. Arteriovenous malformations present…

AdultMalemedicine.medical_specialtyAdolescentDiagnostico diferencialSoft Tissue NeoplasmsMalignancySensitivity and SpecificityDiagnosis Differentialsymbols.namesakeColor doppler ultrasonographyHumansMedicineFalse Positive ReactionsRadiology Nuclear Medicine and imagingUltrasonography Doppler ColorChildFalse Negative ReactionsAgedRadiological and Ultrasound Technologybusiness.industrySoft tissueGeneral MedicineColor dopplerMiddle Agedmedicine.diseaseUltrasonography Doppler PulsedChild PreschoolsymbolsVascular impedanceFemaleRadiologyUltrasonographybusinessDoppler effectActa Radiologica
researchProduct

Evaluation of diastolic function by the Tissue doppler in children affected by non- compaction

2007

The Tissue doppler analysis is a new echocardiographic approach to evaluate the diastolic function. In this report we performed a Tissue doppler analysis in a series of 15 children affected by non-compaction. The bidimensional echo-cardiogram showed a systolic function which was reduced only in 8 patients. Alterations of the diastolic function were founded in 7 patients: in 2 cases, a reduction of the E tissue wave was present in all segments. In 3 patients the diastolic dysfunction was limited to apical and lateral segments. In the last 2 children a reduction of the E wave interested only the apical segments. There was a strong correlation between systolic and diastolic dysfunction: in fac…

AdultMalemedicine.medical_specialtyAdolescentDiastoleSystolic functionDoppler echocardiographysymbols.namesakeDiastoleInternal medicineVentricular DysfunctionmedicineHumansDiastolic functionChildmedicine.diagnostic_testbusiness.industryInfantAnatomyEchocardiography DopplerPulse pressureChild PreschoolsymbolsCardiologyFemaleCardiology and Cardiovascular MedicinebusinessDoppler effectTissue doppler analysis Non-compaction Ventricular dysfunction Children
researchProduct

Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…

1992

In a previous paper, in which the experimental conditions of the present research are fully described (Parrot et al., this issue), heart rate (HR) was studied in 60 male and in 60 female subjects in response to a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), and an intermittent pink noise (R), all noises being emitted at the same LAeq = 75 dB for 15 min. Digital pulse level (PL) responses were concomitantly surveyed by the use of pulse oximetry, allowing continuous arterial oxygen saturation (SaO2) readings. An index of pulse reactivity (PRI) could be calculated. Arterial blood pressure was measured 7 times from the beginning to the end of each trial. At rest, within…

AdultMalemedicine.medical_specialtyAdolescentHemodynamicsBlood PressureAudiologyAnxietyPink noiseImpulse noiseHeart RateOccupational ExposureHeart rateAdaptation PsychologicalmedicineHumansHabituation Psychophysiologicmedicine.diagnostic_testbusiness.industryPulse (signal processing)Public Health Environmental and Occupational HealthHemodynamicsMiddle AgedSurgeryOccupational DiseasesPlethysmographyNoisePulse oximetryBlood pressureNoise TransportationNoise OccupationalFemaleVascular ResistancebusinessArousalInternational archives of occupational and environmental health
researchProduct

Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…

1992

This study aimed at comparing for their cardiovascular effects: a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), an intermittent pink noise (R). All noises were presented at the same LAeq = 75 dB for 15 min each. Some 120 subjects were divided into 8 subgroups of 15 subjects each: OM (men between 40 and 50 years of age), OF (women, same age range), YM (men, between 15 and 20 years of age), YF (women, same age range), AM (typically anxious men, 20–25 years of age), AF (typically anxious women, same age range), NM (typicall anxiety-free men, same age range), and NF (typically anxiety-free women, same age range). Heart rate (HR), digital pulse level, and arterial blood p…

AdultMalemedicine.medical_specialtyAdolescentIndividualityBlood PressureAudiologyAnxietyPink noiseImpulse noiseSex FactorsHeart RateHeart rateAdaptation PsychologicalMedicineHumansRoad trafficPulse noisebusiness.industryPublic Health Environmental and Occupational HealthAge FactorsHemodynamicsMiddle AgedOccupational DiseasesNoiseBlood pressureNoise TransportationNoise OccupationalAnxietyFemaleVascular Resistancemedicine.symptombusinessArousalInternational archives of occupational and environmental health
researchProduct

Relationship between video head impulse test (vHIT) and caloric test in patients with vestibular neuritis.

2016

Abstract Introduction and objectives The caloric test is the gold standard for the loss of vestibular function diagnosis. The video head impulse test (vHIT) assesses the same reflex by using a video-assisted examination of the impulsive manoeuvre. We intend to compare the variation of results of the vHIT and the caloric test in patients with vestibular neuritis with respect to their initial condition at two different moments of their evolution and to check the level of correlation between them and with that of the DHI test. Methods We explored 20 patients with neuritis by using both vHIT and the caloric test on the same day. We assessed the correlation between these two tests and with the D…

AdultMalemedicine.medical_specialtyAdolescentVideo RecordingCaloric testAudiology03 medical and health sciencesYoung Adult0302 clinical medicineVertigoCaloric TestsSaccadesMedicineVideonystagmographyHumansProspective Studies030223 otorhinolaryngologyHead Impulse TestVestibular NeuronitisAgedVestibular systembiologymedicine.diagnostic_testReflex Abnormalbusiness.industryHead impulse testGeneral MedicineGold standard (test)Reflex Vestibulo-OcularMiddle Agedbiology.organism_classificationhumanitiesTest (assessment)ReflexRegression AnalysisFemalebusiness030217 neurology & neurosurgeryFollow-Up StudiesActa otorrinolaringologica espanola
researchProduct

Relationship of Metabolic Syndrome With Pulse Pressure in Patients With Essential Hypertension

2006

BACKGROUND: Pulse pressure is largely dependent on arterial stiffness. Recent studies have documented reduced large artery compliance in nondiabetic subjects with metabolic syndrome (MS). The aim of our study was to analyze, in a group of patients with essential hypertension and without diabetes mellitus, the influence of MS on clinic and 24-h pulse pressures. METHODS: A total of 528 hypertensive subjects, aged 18 to 72 years, who were free of cardiovascular and renal diseases were enrolled. Of the subjects, 41% had MS. In all subjects routine blood chemistry, echocardiographic examination, and 24-h ambulatory blood pressure monitoring were performed. RESULTS: When compared with subjects wi…

AdultMalemedicine.medical_specialtyAmbulatory blood pressureBlood PressureEssential hypertensionHeart RateRisk FactorsDiabetes mellitusInternal medicineInternal MedicineHumansMedicinePulseAgedMetabolic Syndromebusiness.industryBlood Pressure Determinationmetabolic syndrome pulse pressure hypertensionArteriesStroke volumeMiddle Agedmedicine.diseasePulse pressureSurgeryBlood chemistryPulsatile FlowHypertensionCardiologyArterial stiffnessFemaleMetabolic syndromebusinessAmerican Journal of Hypertension
researchProduct

Relationships between 24 h blood pressure load and target organ damage in patients with mild-to-moderate essential hypertension.

2001

Objective: To analyse the relationships between 24 h blood pressure load (the percentage of systolic/diastolic blood pressures exceeding 140/90 mmHg while awake and 120/80 mmHg during sleep) and some indices of hypertensive target organ involvement, independently of the mean level of 24 h blood pressure. Methods: One hundred and thirty patients with mild-to-moderate hypertension underwent 24 h ambulatory blood pressure monitoring, ocular fundus examination, microalbuminuria assay and two-dimensional guided M-mode echocardiography. The study population was divided into subsets according to the systolic and diastolic 24 h blood pressure load values predicted from the regression equation relat…

AdultMalemedicine.medical_specialtyAmbulatory blood pressureFundus OculiSystoleDiastoleBlood PressureAssessment and DiagnosisEssential hypertensionKidneyRetinaElectrolytesDiastoleInternal medicineInternal MedicinemedicineAlbuminuriaHumansSingle-Blind MethodObesityProspective StudiesSystoleAdvanced and Specialized Nursingbusiness.industryMyocardiumGeneral MedicineBlood Pressure Monitoring AmbulatoryMiddle Agedmedicine.diseasePulse pressureMean blood pressureBlood pressuremedicine.anatomical_structureEchocardiographyCreatinineHypertensionVascular resistanceCardiologyFemaleVascular ResistanceCardiology and Cardiovascular MedicinebusinessBlood pressure monitoring
researchProduct

Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.

2011

International audience; Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) mea…

AdultMalemedicine.medical_specialtyBiomedical Engineering[INFO.INFO-IM] Computer Science [cs]/Medical Imaging030204 cardiovascular system & hematologyCardiography Impedance03 medical and health sciencesVascular Stiffness0302 clinical medicineNuclear magnetic resonanceInternal medicinemedicine.arterymedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansPulse wave velocityAortaAgedAortamedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryModels CardiovascularSignal Processing Computer-AssistedMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingComputer Science ApplicationsImpedance cardiographyDragCardiologyArterial stiffnessFemaleAortic stiffnessElectrophysiologic Techniques CardiacbusinessBioelectrical impedance analysisAlgorithms030217 neurology & neurosurgery
researchProduct