Search results for "PULSE"
showing 10 items of 1508 documents
Safety and feasibility of a neuromuscular electrical stimulation chronaxie-based protocol in critical ill patients: A prospective observational study
2017
International audience; Purpose: The aim of this study was to evaluate the safety and feasibility of a neuromuscular electrical stimulation (NMES) protocol based on neuromuscular excitability and applied in numerous muscle groups of critical ill patients.Materials and methods: We performed a prospective observational study using an NMES applied daily and bilaterally into 5 muscle groups in lower limbs for 3 consecutive days. The characteristics of NMES were 90 contractions per muscle, pulse width equal to chronaxie, and a pulse frequency of 100 Hz. We assessed safety with central venous oxygen saturation, serum lactate, and creatine phosphokinase measurements. To evaluate feasibility, we re…
Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques
2008
Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …
Color doppler ultrasonography of soft-tissue masses
1998
Purpose: To evaluate the capability of color Doppler ultrasonography to differentiate between benign and malignant soft-tissue tumors. Material and Methods: We reviewed the ultrasonographic (US) and color Doppler (CD) findings in 46 consecutive patients with a palpable periskeletal mass. The presence of 3 or more vascular hila and of tortuous and irregular internal vessels within the lesions was considered an indication of malignancy. The CD diagnosis was compared with that obtained at US alone. Results: The sensitivity and specificity of CD were respectively 85% and 92%; these values were higher than those obtained at US alone, respectively 75% and 50%. Arteriovenous malformations present…
Evaluation of diastolic function by the Tissue doppler in children affected by non- compaction
2007
The Tissue doppler analysis is a new echocardiographic approach to evaluate the diastolic function. In this report we performed a Tissue doppler analysis in a series of 15 children affected by non-compaction. The bidimensional echo-cardiogram showed a systolic function which was reduced only in 8 patients. Alterations of the diastolic function were founded in 7 patients: in 2 cases, a reduction of the E tissue wave was present in all segments. In 3 patients the diastolic dysfunction was limited to apical and lateral segments. In the last 2 children a reduction of the E wave interested only the apical segments. There was a strong correlation between systolic and diastolic dysfunction: in fac…
Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…
1992
In a previous paper, in which the experimental conditions of the present research are fully described (Parrot et al., this issue), heart rate (HR) was studied in 60 male and in 60 female subjects in response to a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), and an intermittent pink noise (R), all noises being emitted at the same LAeq = 75 dB for 15 min. Digital pulse level (PL) responses were concomitantly surveyed by the use of pulse oximetry, allowing continuous arterial oxygen saturation (SaO2) readings. An index of pulse reactivity (PRI) could be calculated. Arterial blood pressure was measured 7 times from the beginning to the end of each trial. At rest, within…
Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…
1992
This study aimed at comparing for their cardiovascular effects: a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), an intermittent pink noise (R). All noises were presented at the same LAeq = 75 dB for 15 min each. Some 120 subjects were divided into 8 subgroups of 15 subjects each: OM (men between 40 and 50 years of age), OF (women, same age range), YM (men, between 15 and 20 years of age), YF (women, same age range), AM (typically anxious men, 20–25 years of age), AF (typically anxious women, same age range), NM (typicall anxiety-free men, same age range), and NF (typically anxiety-free women, same age range). Heart rate (HR), digital pulse level, and arterial blood p…
Relationship between video head impulse test (vHIT) and caloric test in patients with vestibular neuritis.
2016
Abstract Introduction and objectives The caloric test is the gold standard for the loss of vestibular function diagnosis. The video head impulse test (vHIT) assesses the same reflex by using a video-assisted examination of the impulsive manoeuvre. We intend to compare the variation of results of the vHIT and the caloric test in patients with vestibular neuritis with respect to their initial condition at two different moments of their evolution and to check the level of correlation between them and with that of the DHI test. Methods We explored 20 patients with neuritis by using both vHIT and the caloric test on the same day. We assessed the correlation between these two tests and with the D…
Relationship of Metabolic Syndrome With Pulse Pressure in Patients With Essential Hypertension
2006
BACKGROUND: Pulse pressure is largely dependent on arterial stiffness. Recent studies have documented reduced large artery compliance in nondiabetic subjects with metabolic syndrome (MS). The aim of our study was to analyze, in a group of patients with essential hypertension and without diabetes mellitus, the influence of MS on clinic and 24-h pulse pressures. METHODS: A total of 528 hypertensive subjects, aged 18 to 72 years, who were free of cardiovascular and renal diseases were enrolled. Of the subjects, 41% had MS. In all subjects routine blood chemistry, echocardiographic examination, and 24-h ambulatory blood pressure monitoring were performed. RESULTS: When compared with subjects wi…
Relationships between 24 h blood pressure load and target organ damage in patients with mild-to-moderate essential hypertension.
2001
Objective: To analyse the relationships between 24 h blood pressure load (the percentage of systolic/diastolic blood pressures exceeding 140/90 mmHg while awake and 120/80 mmHg during sleep) and some indices of hypertensive target organ involvement, independently of the mean level of 24 h blood pressure. Methods: One hundred and thirty patients with mild-to-moderate hypertension underwent 24 h ambulatory blood pressure monitoring, ocular fundus examination, microalbuminuria assay and two-dimensional guided M-mode echocardiography. The study population was divided into subsets according to the systolic and diastolic 24 h blood pressure load values predicted from the regression equation relat…
Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.
2011
International audience; Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) mea…