Investigation on partial discharges in HVDC cables after polarity reversal events
2020
Due to the accumulation of space charge inside the insulating layer of HVDC cables, the electric field under load conditions may be altered compared to what is established in HVAC cables. For example, a high thermal gradient leads to the inversion of the electric field pattern until the maximum value is reached in proximity of the dielectric-semicon interfaces. These maximum values can be further increased due to transient overvoltages and polarity reversal events until reaching electric field values higher than the rated ones. The main goal of this research is to investigate the possibility that, during these transient phenomena, conditions are created that favor the occurrence of partial …
Effect of Polarity Reversal on the Partial Discharge Phenomena
2020
In the field of High Voltage Direct Current (HVDC) transmission, the space charge accumulation phenomenon and the Partial Discharges (PD) phenomena are considered the main causes of dielectric ageing. During the years, the degradation effect of both phenomena under constant DC stress has been widely studied by several researchers. In case of polarity reversal, typically carried out to control bi-directional power flow between interconnected High Voltage transmission systems, the space charge movement may not synchronously follow the electric field polarity. This could make the moment of reversing polarity a very critical one, where space charge injected during preceding polarity produces hi…
The Effect of the Harmonic Content Generated by AC/DC Modular Multilevel Converters on HVDC Cable Systems
2019
With the increasing penetration of renewable and decentralized energy sources into the power grid, an extended use of DC voltages is expected on both distribution and transmission levels. Generation of DC voltages by means of voltage source converters is associated with a wide spectrum of harmonic distortions at converter terminals, both on the ac and on the dc sides. This can lead to partial discharges in power cables, which deteriorate insulation material thus weakening its performance and reducing cable life-time. In the previously published paper, the effect of harmonic distortion on appearance of partial discharges in cable insulation was evaluated. Here, the study related to the PD be…
A new technique for partial discharges measurement under DC periodic stress
2017
The aim of the present work is to recognize the type of defect in insulating materials employed in DC electrical systems. This analysis, under AC stress, is carried out by using the Phase Resolved method (PRPD). While, under constant voltage stress this method cannot be performed and measurements show complexities. In order to overcome these problems, a new technique is proposed, based on the application of a periodic continuous waveform. Simulation results, carried out by using a model based on a time-variable conductance of an air void defect, showed the PRPD pattern that can be obtain. Furthermore, compared to the constant DC stress, the measurement duration became lower and the discharg…
Identification of a specific type of PD from acoustic emission frequency spectra
2001
The paper presents an attempt to apply spectral analysis tools in processing acoustic emission (AE) pulses generated by partial discharge (FD). The experimental part of the paper describes spark gaps generating four types of PD and specifies parameters of measured acoustic signals and recalls the system used for measurement and analysis of the frequency spectra. Also, a spectral analysis procedure is presented, and frequency-domain descriptors characterizing AE pulses are defined. The results of the analysis are given both as time plots and amplitude and energy density spectra, related to values of the associated descriptors. The spectral analysis results cover AE pulses generated in system…
A new approach to partial discharge detection under DC voltage
2018
The continuing development of HVDC power transmission systems presents many problems related to evaluation of the reliability of power system assets [1]-[5]. In this context the identification of insulation defects plays a key role in preventing unexpected failures of electrical components. Partial discharge (PD) measurement is a useful approach to assessing the condition of HV power apparatus and cables. Such measurements are also widely employed for HVAC systems. The inception mechanisms of PD in AC systems are well-known, and measurements are usually performed following the IEC 60270 standard [6]. PD measurements under DC voltage present complexities related to the nature of the phenomen…
The possibilities of using the acoustic emission method in expert systems for the evaluation of insulation systems of power transformers
2006
The paper presents the range and possibilities of using expert systems at diagnostic measurements of insulation systems of power appliances taken by the acoustic emission (AE) method. Multi-parametric descriptors characterizing the AE signals, which can be used in the knowledge base as criteria making the identification of basic partial discharge forms (PDs) possible, have been characterized in detail. The tables show descriptors describing the AE signals registered in time, frequency, time-frequency domains and statistical data. Moreover, computational tools that can be used in the process of conclusion drawing were suggested and the range of the research work done by the authors of the pa…
An improved MSD-based method for PD defects classification
2006
The new proposed method of pattern recognition is based on the application of Multi-resolution Signal Decomposition (MSD) technique of wavelet transform. This technique has showed off interesting properties in capturing the embedded horizontal, vertical and diagonal variations within an image obtained from the PD pattern in a separable form. This feature was exploited to identify in the PD pattern's MSD, relative at various family of partial discharge sources, some detail images typical of a single discharge phenomenon. The classification of a generic PD phenomenon is feasible through a comparison between its detail images and the detail images typical of a single discharge phenomenon. Test…
Electromagnetic Full-Wave Simulation of Partial Discharge Detection in High Voltage AC Cables
2019
Partial discharge (PD) activity in the insulation system of an electrical equipment can determine the failure of the whole apparatus. PD sensors are widely used in high-voltage electrical systems as the main elements of a detecting system oriented to real time monitoring. Recently, non-invasive sensors have been proposed in industrial applications for cable and other sensitive electrical parts: they are based both on capacitive and on the electromagnetic radiating coupling. In order to assess the real performance of a new sensor produced by a high voltage AC cables manufacturer, the paper proposes electromagnetic fullwave simulation results.
Statistical analysis techniques for Partial Discharges measurement under DC voltage
2022
Partial discharges (PD) phenomenon for HVAC (High-Voltage-Alternating-Current) systems has already been widely studied in literature and from this it has been possible to produce a regulatory document that provides indications for description and identification of the different types of discharges. However, the growing diffusion of HVDC (High-Voltage-Direct-Current) systems makes necessary the development of analysis techniques also for DC case. In this paper data obtained from PD measurement under DC voltage were analyzed through the time-frequency map combined with a density-based clustering algorithm. The results show that, with this approach, it's possible to perform a noise rejection a…