Search results for "Partial discharge"

showing 10 items of 70 documents

Wireless partial discharge tracking on cross-linked polyethylene MV and HV cables

2018

Medium voltage (MV)/high voltage (HV) cable lines are high-value assets and require substantial costs for their installation or replacement. For this reason, the capability to assess the condition of cable lengths and accessories on site is of great importance. Cross-linked polyethylene (XLPE) insulation is extensively used for MV, HV, and extra-high voltage (EHV) class cables [1] thanks to its excellent voltage-endurance and thermomechanical properties. In particular, XLPE-insulated cables feature substantially lower losses, easier manufacturing and jointing procedures, better environmental compatibility, and higher operating temperature compared with impregnated paper cables, which lead t…

Materials sciencecross-linked polyethylene insulation01 natural scienceschemistry.chemical_compoundOperating temperaturepower cable testing0103 physical sciencesWirelessPower cablefault locationElectrical and Electronic Engineeringcable insulation010302 applied physicsCross-linked polyethylenebusiness.industryElectronic Optical and Magnetic Material010401 analytical chemistryElectrical engineeringfault diagnosiHigh voltagePolyethylene0104 chemical sciencesElectronic Optical and Magnetic Materialspartial dischargechemistryPartial dischargebusinesspower cableVoltageIEEE Electrical Insulation Magazine
researchProduct

Detection of Partial Discharges at Square Shaped Voltages

2018

Due to the wide use of electronic converters and the introduction of new powerful power electronics devices, the input waveforms most often used are becoming much different than the traditional power frequent sinusoidal one. In High Voltage (HV) apparatus particularly, this condition can increase the stress on the insulation systems that may lower the reliability of the whole power grid. This type of input voltage, often showing an increased voltage gradient, causes problems in the Partial Discharge (PD) measurement setup and acquisition systems, also due to the increased harmonic content. In this paper, the main aim is to discuss how to suitably approach the measurement technique of PDs at…

Materials scienceunconventional streRenewable Energy Sustainability and the Environmentbusiness.industrypattern recognitionElectrical engineeringEnergy Engineering and Power TechnologyComputer Science Applications1707 Computer Vision and Pattern RecognitionHigh voltageConvertersIndustrial and Manufacturing EngineeringPower (physics)Computer Networks and CommunicationReliability (semiconductor)Artificial IntelligencePartial dischargePower electronicsPartial dischargeHarmonicPWMbusinessInstrumentationVoltage2018 IEEE 4th International Forum on Research and Technology for Society and Industry (RTSI)
researchProduct

On the Secondary Discharge of an Atmospheric-Pressure Pulsed DBD in He with Impurities

2008

The secondary discharge was induced at the end of a slow-falling voltage flank, when a semisine monopolar pulse voltage excites the dielectric-barrier discharge. Formation and properties of the secondary discharge with respect to different dielectric materials such as glass, ceramic, and polyethylene theraphtalate were studied. The tunable diode laser absorption spectrometry (at 777.194 nm) was used to analyze the time-space distribution of the density of the atomic oxygen in metastable state (35S2 rarr 35P3) in addition to both discharge voltage and discharge current versus time. The secondary discharge is always formed, and its amplitude, as well as the amplitude of the main discharge, de…

Nuclear and High Energy PhysicsMaterials scienceAtmospheric pressurechemistry.chemical_elementDielectric barrier dischargeDielectricCondensed Matter Physicschemistryvisual_artPartial dischargevisual_art.visual_art_mediumPlasma diagnosticsCeramicAtomic physicsHeliumTunable laserIEEE Transactions on Plasma Science
researchProduct

Dielectric properties and partial discharge endurance of polypropylene-silica nanocomposite

2010

This paper presents the results of the dielectric properties and partial discharge endurance measurements conducted on polypropylene (PP)-silica nanocomposite. The material compounds were analyzed with micro-Raman spectroscopy, X-ray tomography and transmission electron microscopy (TEM). ac and dc breakdown strength of the materials was measured. Dielectric response, capacitance and loss factor of the film samples were measured as a function of temperature and frequency. Partial discharge (PD) endurance of the reference PP and PP Silica nanocomposite was studied as a function of ac voltage. Material surfaces were analyzed after PD stress with optical microscopy. All dielectric measurements …

PermittivityMaterials scienceNanocompositeAnalytical chemistryDielectricCapacitancelaw.inventionCapacitorpartial dischargelawdielectric propertiessilicaPartial dischargeDielectric lossElectrical and Electronic EngineeringThin filmComposite materialpolypropyleneIEEE Transactions on Dielectrics and Electrical Insulation
researchProduct

Building Partial Discharge Signal Wireless Probes

2014

This chapter focuses on the evaluation of the performances of different antenna sensors suitable for Partial Discharge (PD) measurements. Monopole, triangular and spherical antennas were simulated by means of the surface method of moments. The transmitting system is modeled by a power electronic device with a fault current between two metal plates. The shape of the simulated, transmitted and received signals, has been compared to verify the sensor that provides the best fidelity among the three. The auto-correlation function and the Pearson correlation index are adopted here for the comparison. A discussion on the dynamic characteristic of the different antenna probes and their use in diffe…

PhysicsSettore ING-IND/31 - Elettrotecnicabusiness.industryPartial dischargeElectrical engineeringElectronic engineeringWirelessantenna partial discharges method of momentsbusinessSignal
researchProduct

The effect of Transient over Voltages on the Partial Discharges activity in HVDC joints

2021

Rapid growth of HVDC cable line installations is expected in the coming years. Several research groups have investigated dielectric phenomena that occur in the insulation of HVDC cables and accessories that accelerate aging and reduce the reliability of this technology over time. Unlike in HVAC cables, under HVDC stress, the distribution of the electric field inside the insulation layer depends not only on the applied voltage but also on the temperature distribution and on other factors related to manufacturing such as the presence of impurities. Reaching local and transient electric field peaks can enhance the onset of Partial Discharges (PDs) which can lead to premature aging of the insul…

Premature agingMaterials scienceHVDCPartial Dischargesfood and beveragesSpace ChargeDielectricMechanicsSpace chargeStress (mechanics)Transient Over VoltagesOvervoltageElectric fieldDielectric phenomenaTransient (oscillation)Voltage
researchProduct

Model of ageing inception and growth from microvoids in polyethylene-based materials under AC voltage

2008

Several degradation mechanisms may affect polymeric insulation system reliability. Some authors postulate that, even in a perfect dielectric, nanoscale cavities can enlarge due to various mechanisms (from mechanical fatigue to lowering of the degradation reaction energy barrier) up to a point where highly energetic phenomena, which bring about breakdown, can be incepted. Other authors are more focused on the inherent limits of manufacturing processes, which leave cavities within the insulation system whose size is large enough to cause electron avalanches, thus a measurable partial discharge (PD) activity, from the time the system is put in service or as a function of external factors (e.g.…

Reliability (semiconductor)Materials scienceInsulation systemThermalPartial dischargeForensic engineeringDielectricElectrical treeingComposite materialVoltageDegradation (telecommunications)2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena
researchProduct

Test procedures for use of wireless partial discharges instrumentation in HV networks

2014

On-field diagnostic methods based on Partial Discharge (PD) measurements for asset assessment in High Voltage (HV) sectors are experiencing a constant growth in recent years. This rise of interest motivated the research toward faster, reliable and less expensive methods and technologies to perform PD measurements. Recently, a portable instrument based on a wideband antenna sensor, intended for accurate partial discharge measurements, has been developed by the authors. This sensor allows to capture electromagnetic waves in a bandwidth ranging from 0.1-100 MHz as well as the electric field of the AC supply voltage to be used as a phase reference. This approach completely avoid the need of a d…

Settore ING-IND/31 - ElettrotecnicaAntennaPartial DischargeInstrumentationSettore ING-INF/01 - ElettronicaWireleSensor
researchProduct

Performances of a PCB-based Loop Antenna Inductive Sensor for Partial Discharges Detection

2022

This paper presents the test results of an electrically small loop antenna sensor towards detecting the radiated magnetic field due to partial discharge (PD) activities. The loop antenna prototype was printed on an FR-4 substrate with a thickness of 1.6 mm, featuring a compact size of 20 mm times20 mm times1.7 mm. The proposed sensor, initially simulated with Ansys HFSS software, has a resonant frequency of about 100 MHz. Its detection capability for three types of partial discharges (i.e., corona, surface and internal PDs) has been evaluated. Laboratory experiments showed that the evaluated loop spiral antenna is appropriate for the detection of the three types of PDs. Indeed, the results …

Settore ING-IND/31 - ElettrotecnicaHFCT sensorInductive spiral loop; PCB-based sensor; Partial discharge detection; HFCT sensorpartial discharge detectionPCB-based sensorInductive spiral loop
researchProduct

Partial discharges characteristics during load transients in an HVDC model cable

2021

The occurrence of Partial Discharges (PD) in HVAC cables is widespread considered as one of the most important concerns for the stability of the insulation. To date, the role of PD in the ageing and definitive fault of HVDC cables has been poorly investigated. This is mainly due to some practical difficulties in the performing of the measurements. Compared to the PDs occurring under AC stress, the higher inception voltages and the lower repetition rates, obtainable under DC voltage, make the exclusion of the measurement noise more difficult. This paper is focused on the study of the characteristics of the PDs occurring in an artificial defect located in proximity of the outer dielectric' su…

Settore ING-IND/31 - ElettrotecnicaHVDC cable partial discharge space charge
researchProduct