Search results for "Partial"
showing 10 items of 1477 documents
Electrical Aging Tests on Enameled Wire Exposed to Gamma Irradiation
2011
Intracranial measurement of current densities induced by transcranial magnetic stimulation in the human brain
2003
Transcranial magnetic stimulation (TMS) is a non-invasive technique that uses the principle of electromagnetic induction to generate currents in the brain via pulsed magnetic fields. The magnitude of such induced currents is unknown. In this study we measured the TMS induced current densities in a patient with implanted depth electrodes for epilepsy monitoring. A maximum current density of 12 microA/cm2 was recorded at a depth of 1 cm from scalp surface with the optimum stimulation orientation used in the experiment and an intensity of 7% of the maximal stimulator output. During TMS we recorded relative current variations under different stimulating coil orientations and at different points…
Electromagnetic radiated field measurements for partial discharge diagnostic
2004
Recently, improvements have been made in the diagnostic of electrical insulation systems by means of electric Partial Discharge (PD) standard measurements through a stochastic approach in the treatment of the acquired data: in this way, the identification of the defects as well as the separation of multiple defects simultaneously active, have been successfully performed. However, the standard PD measurement process can be affected by the well-known parasitic effects due to conducted noise whose spectrum can have characteristics similar to those of the measured signal. Moreover, the classic PD measurement system have to be suitable assembled on the Device Under Test (DUT) so determining a co…
Partial Discharge on-line measures in cable's EPR insulation
2004
In this paper, an experimental study, carried out on an operating MV cable, is presented. The aim is to identify, locate and characterize defects in the cable's EPR (ethylene-propylene copolymer rubber) insulation. Direct partial discharge measurements have been compared to those obtained by high frequency electromagnetic field measures. The latter have been carried out using a sensor which does not require any galvanic connection with the system under test and that performs an intrinsic localization of the defect. Moreover, an analysis of an MV cable junction has been carried out using the same tools.
Time-dependent Casimir-Polder forces and partially dressed states
2002
A time-dependent CasimirPolder force is shown to arise during the time evolution of a partially dressed two-level atom. The partially dressed atom is obtained by a rapid change of an atomic parameter such as its transition frequency, due to the action of some external agent. The electromagnetic field fluctuations around the atom, averaged over the solid angle for simplicity, are calculated as a function of time, and it is shown that the interaction energy with a second atom yields a dynamical CasimirPolder potential between the two atoms.
High-Temperature Hall Measurements on BaSnO3Ceramics
2005
Simultaneous Hall and conductivity measurements were performed in situ between 650° and 1050°C on n-type semiconducting BaSnO3ceramics. The variation of the Hall mobility and the Hall carrier density as a function of oxygen partial pressure between 102 and 105 Pa and of temperature was investigated. At temperatures below 900°C the conductivity exhibits a dependence on temperature and oxygen partial pressure which is mainly determined by variations of the Hall mobility. Above 900°C most of the significant dependence is due to a variation in carrier density. Furthermore, a simple defect model assuming doubly ionized oxygen vacancies and acceptor impurities is discussed for BaSnO3.
Boundary accessibility and elliptic harmonic measures
1988
Suppose G is a bounded domain in R n such that the complement of G satisfies a capacity dcnsity condition. It is shown that all elliptic measures in G have a support set with Moreover, the capacity density condition cannot be removed. A nonlinear version of the result is also given.
Partial Elastic Scheme Method in Cantilever Construction of Concrete Arch Bridges
2013
AbstractIn this paper, a study about stay stressing procedures of concrete arch bridges built by cantilevering with temporary stays is presented. Particularly, the partial elastic scheme method is proposed to find the initial cable forces, and a forward procedure is implemented to follow the actual sequence of construction by extending a procedure already applied to concrete cable–stayed bridges. The theoretical treatment is followed by a numerical application on a case study of a concrete arch bridge, and a comparison between initial cable forces found by the partial elastic scheme method and classical backward analysis is presented here. Results show the effectiveness of the proposed proc…
CFD simulations of dense sloid-liquid suspensions in baffled stirred tanks: Prediction of suspension curves
2011
Mixing of solid particles into liquids within contactors mechanically agitated by stirrers is a topic of primary importance for several industrial applications. A great research effort has been devoted to the assessment of the minimum impeller speed (Njs) able to guarantee the suspension of all particles. Conversely, only little attention has been paid so far to the evaluation of the amount of solid particles that are suspended at impeller speeds lower than Njs. In some cases the loss in available interfacial area between particles and liquid could be reasonably counterbalanced by a decreased mechanical power, making it of interest to evaluate the percentage of suspended solids at different…
Overcoming synchronization issues in wireless technology Partial Discharge measurement
2016
In this paper, several aspects of the fundamentals of wireless Partial Discharge (PD) measurements are first discussed. Then, the relevance of the problem of voltage synchronization in PD wireless diagnosis is outlined. When portable instruments are used for PD detection, the main issue is the voltage measurement at the site where the PD detection is carried out. When such analysis is carried out over shielded cables, the AC (50/60 Hz) voltage reference signal is not easily detectable, while one of the basic parameters for PD diagnosis, the displacement of the inception voltage of the PD as compared to the reference voltage, is not available. Even if highperformance sensors are readily avai…