Search results for "Partial"
showing 10 items of 1477 documents
Determination of vinegar acidity by attenuated total reflectance infrared measurements through the use of second-order absorbance-pH matrices and par…
2007
Univariate (zero-order), multivariate (first-order) and multiway (second-order) calibrations were assayed for the determination of vinegar acidity using a mechanized procedure based upon vibrational spectroscopy and the emerging multicommutation methodology. The second-order methodology relies on the use of a flow system based on multicommutation and binary sampling. The flow network comprises a set of three-way solenoid valves, computer-controlled to provide facilities to handle the sample and to generate a time-dependent pH gradient using two carrier solutions. The procedure is based on the volumetric fraction variation approach that maintains the same volume of sample solution and dynami…
Measuring frequency domain granger causality for multiple blocks of interacting time series
2011
In the past years, several frequency-domain causality measures based on vector autoregressive time series modeling have been suggested to assess directional connectivity in neural systems. The most followed approaches are based on representing the considered set of multiple time series as a realization of two or three vector-valued processes, yielding the so-called Geweke linear feedback measures, or as a realization of multiple scalar-valued processes, yielding popular measures like the directed coherence (DC) and the partial DC (PDC). In the present study, these two approaches are unified and generalized by proposing novel frequency-domain causality measures which extend the existing meas…
Extended causal modeling to assess Partial Directed Coherence in multiple time series with significant instantaneous interactions.
2010
The Partial Directed Coherence (PDC) and its generalized formulation (gPDC) are popular tools for investigating, in the frequency domain, the concept of Granger causality among multivariate (MV) time series. PDC and gPDC are formalized in terms of the coefficients of an MV autoregressive (MVAR) model which describes only the lagged effects among the time series and forsakes instantaneous effects. However, instantaneous effects are known to affect linear parametric modeling, and are likely to occur in experimental time series. In this study, we investigate the impact on the assessment of frequency domain causality of excluding instantaneous effects from the model underlying PDC evaluation. M…
Combination of mid- and near-infrared spectroscopy for the determination of the quality properties of beers
2006
Abstract The combination of infrared (MIR) and near-infrared (NIR) spectroscopy has been employed for the determination of important quality parameters of beers, such as original and real extract and alcohol content. A population of 43 samples obtained from the Spanish market and including different types of beer, was evaluated. For each technique, spectra were obtained in triplicate. In the case of NIR a 1 mm pathlength quartz flow cell was used, whereas attenuated total reflectance measurements were used in MIR. Cluster hierarchical analysis was employed to select calibration and validation data sets. The calibration set was composed of 15 samples, thus leaving 28 for validation. A critic…
Partial least squares X-ray fluorescence determination of trace elements in sediments from the estuary of Nerbioi-Ibaizabal River.
2010
The feasibility of partial least squares (PLS) regression modeling of X-ray fluorescence (XRF) spectra of estuarine sediments has been evaluated as a tool for rapid trace element content monitoring. Multivariate PLS calibration models were developed to predict the concentration of Al, As, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Sn, V and Zn in sediments collected from different locations across the estuary of the Nerbioi-Ibaizabal River (Metropolitan Bilbao, Bay of Biscay, Basque Country). The study was carried out on a set of 116 sediment samples, previously lyophilized and sieved with a particle size lower than 63 microm. Sample reference data were obtained by inductively coupled plasma mass …
Photocatalytic activity of binary and ternary SnO2–ZnO–ZnWO4 nanocomposites
2015
Binary and ternary SnO2-ZnO-ZnWO4 nanocomposites were prepared by a sol-gel route. The photocatalytic activity of the samples was evaluated through the decomposition of 4-nitrophenol and partial oxidation of 4-methoxybenzyl alcohol to p-anisaldehyde. All the mixed catalysts revealed higher photoactivity than bare ZnO, SnO2 or ZnWO4 and the best performances were exhibited by the binary nanocomposites. The high photocatalytic activity was explained by the presence of heterojunctions among different semiconductors that enhance the separation of the photogenerated electron-hole pairs, hindering their recombination. As a general consideration, an essential role was played by the electronic feat…
Nanosponge-C3N4 composites with improved photocatalytic activity for selective partial alcohol oxidation in aqueous suspension
2022
Composites of C3N4 with nanosponges based on β-cyclodextrins containing a 5% w/w of C3N4 were synthesised, physicochemicaly characterised and tested as heterogeneous photocatalysts for the degradation of 4-nitrophenol and for the partial oxidation of 5-hydroxymethyl-2-furfural and veratryl alcohol. The results outline a synergistic effect in terms of conversion and selectivity. The association of the nanosponges with the C3N4 enhances the photocatalytic activity of the semiconductor, possibly due to the local concentration effect occurring on the photocatalyst surface that would involve a concentration into the nanosponge matrix ca. 500 times larger than in the solution bulk. Composites of …
A green method for the determination of cocaine in illicit samples
2013
Abstract Direct determination of cocaine in untreated seized samples has been made based on diffuse reflectance measurements of the near infrared (NIR) radiation through samples contained inside standard glass vials. The method used a series of previously analyzed samples, by the reference gas chromatography method, to build a partial least squares calibration model which was validated using an independent set of samples. The use of a general model for samples containing from 11.38% till 86.44% (w/w) cocaine was based on the use of spectral ranges from 12500.7 to 10128.6, 9339.8 to 6967.7 and 5388.3 to 4597.6 cm−1 with previous first derivative and vector normalization data pre-processing a…
Open Radical Nephrectomy: 35 Years of Experience at the “Luciano Giuliani” Urological Department of the University of Genoa
2006
Objective: Radical nephrectomy remains the gold standard for surgically resectable kidney neoplasms > 4 cm and, in selected cases, also in presence of metastatic disease. We reviewed the records of the patients having surgery at the University of Genoa in the last 35 yr. Methods: We have retrospectively assessed all the radical nephrectomies performed between 1970 and 2005. Among tumours of the kidney subjected to surgical treatment during this period, we found 1105 cases of histologically proven renal cell carcinoma (RCC), 965 of which had records available for the study. The number of cases per year, symptoms at diagnosis, surgical strategy, staging of the tumour, and survival were rev…
Heparin–polynitroxides: Synthesis and preliminary evaluation as cardiovascular EPR/MR imaging probes and extracellular space-targeted antioxidants
2011
We report here the synthesis of heparin-polynitroxide derivatives (HPNs) in which nitroxide moieties are linked either to uronic acid or glycosamine residues of the heparin macromolecule. HPNs have low anticoagulant activity, possess superoxide scavenging properties, bind to the vascular endothelium/extra-cellular matrix and can be detected by EPR and MRI techniques. As the vascular wall-targeted redox-active paramagnetic compounds, HPNs may have both diagnostic (molecular MRI) and therapeutic (ecSOD mimics) applications.