Search results for "Particle accelerator"
showing 10 items of 180 documents
Measurement of the $W$ boson mass with the D0 detector
2012
We give a detailed description of the measurement of the $W$ boson mass, $M_W$, performed on an integrated luminosity of 4.3 fb$^{-1}$, which is based on similar techniques as used for our previous measurement done on an independent data set of 1 fb$^{-1}$ of data. The data were collected using the D0 detector at the Fermilab Tevatron Collider. This data set yields $1.68\times 10^6$ $W\rightarrow e\nu$ candidate events. We measure the mass using the transverse mass, electron transverse momentum, and missing transverse energy distributions. The $M_W$ measurements using the transverse mass and the electron transverse momentum distributions are the most precise of these three and are combined …
Search for lepton flavor violating decays τ±→l± ω
2008
A search for lepton flavor violating decays of a {tau} to a lighter-mass charged lepton and an {omega} vector meson is performed using 384.1 fb{sup -1} of e{sup +}e{sup -} annihilation data collected with the BABAR detector at the Stanford Linear Accelerator Center PEP-II storage ring. No signal is found, and the upper limits on the branching ratios are determined to be {beta}({tau}{sup {+-}} {yields} e{sup {+-}}{omega}) < 1.1 x 10{sup -7} and {beta}({tau}{sup {+-}} {yields} {mu}{sup {+-}}{omega}) < 1.0 x 10{sup -7} at 90% confidence level.
Operation and characterization of a windowless gas jet target in high-intensity electron beams
2021
Abstract A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with different target gases, e.g., hydrogen, deuterium , helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spectrometer facility at the electron accelerator MAMI. This paper focuses on the developed handling procedures and diagnostic tools, and on the performance of the gas jet target under beam conditions. Considering the special features of this type of target, it proves to be well suited for a n…
High-gradient testing of an $S$-band, normal-conducting low phase velocity accelerating structure
2020
A novel high-gradient accelerating structure with low phase velocity, $v/c=0.38$, has been designed, manufactured and high-power tested. The structure was designed and built using the methodology and technology developed for CLIC $100\text{ }\text{ }\mathrm{MV}/\mathrm{m}$ high-gradient accelerating structures, which have speed of light phase velocity, but adapts them to a structure for nonrelativistic particles. The parameters of the structure were optimized for the compact proton therapy linac project, and specifically to 76 MeV energy protons, but the type of structure opens more generally the possibility of compact low phase velocity linacs. The structure operates in S-band, is backward…
The upgraded DO detector
2006
The DØ experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid-argon calorimeters and central muon detector, remaining from Run I, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of s…
Correlation between ferrous ammonium sulfate concentration, sensitivity and stability of Fricke gel dosimeters exposed to clinical X-ray beams
2014
Abstract This work describes the characterization of various Fricke-Agarose-Xylenol gels (FXG) dosimeters using NMR relaxometry and MRI analysis. Using X-rays from a clinical linear accelerator (LINAC), the gels were irradiated in the dose range from 0 Gy to 20 Gy. The photon sensitivity of the FXGs was measured in terms of NMR relaxation rates; its dependence on radiation dose was determined as a function of ferrous ammonium sulfate contents (from 0.5 mM to 5 mM). Furthermore, the stability of the NMR signal was monitored over several days after irradiation. These measurements were aided by Magnetic Resonance Imaging (MRI) scans which allowed three-dimensional (3D) dose mapping. In order t…
The BLAST experiment
2009
The Bates large acceptance spectrometer toroid (BLAST) experiment was operated at the MIT-Bates Linear Accelerator Center from 2003 until 2005. The detector and experimental program were designed to study, in a systematic manner, the spin-dependent electromagnetic interaction in few-nucleon systems. As such the data will provide improved measurements for neutron, proton, and deuteron form factors. The data will also allow details of the reaction mechanism, such as the role of final state interactions, pion production, and resonances to be studied. The experiment used: a longitudinally polarized electron beam stored in the South Hall Storage Ring; a highly polarized, isotopically pure, inter…
Mechanisms of Electron-Induced Single-Event Latchup
2019
In this paper, possible mechanisms by which electrons can induce single-event latchups in electronics are discussed. The energy deposition and the nuclear fragments created by electrons in silicon are analyzed in this context. The cross section enhancement effect in the presence of high-Z materials is discussed. First experimental results of electron-induced latchups are shown in static random access memory devices with low linear energy transfer thresholds. The radiation hardness assurance implications and future work are discussed.
Observation ofY(3940)→J/ψωinB→J/ψωKatBABAR
2008
We present a study of the decays B;{0,+}-->J/psiomegaK;{0,+} using 383x10;{6} BB[over ] events obtained with the BABAR detector at PEP-II. We observe Y(3940)-->J/psiomega, with mass 3914.6_{-3.4};{+3.8}(stat)+/-2.0(syst) MeV/c;{2}, and width 34_{-8};{+12}(stat)+/-5(syst) MeV. The ratio of B0 and B+ decay to YK is 0.27_{-0.23};{+0.28}(stat)-0.01+0.04(syst), and the relevant B0 and B+ branching fractions are reported.
Polarimetry at MAMI
2013
Moller and Mott polarimeters have been compared concerning their measurement accuracy in a dedicated "spin dance" experiment. The results obtained with the different polarimeters at vastly different energy ranges were in agreement with each other within the given systematic uncertainties of a few percent. We discuss investigations of background conditions which may allow to reduce this important contribution to the uncertainties in the Mott polarimeter to a value below 1.0%.