Search results for "Particle accelerator"

showing 10 items of 180 documents

Search for charged massive long-lived particles

2012

We report on a search for charged massive long-lived particles (CMLLPs), based on 5.2 fb$^{-1}$ of integrated luminosity collected with the D0 detector at the Fermilab Tevatron $p\bar{p}$ collider. We search for events in which one or more particles are reconstructed as muons but have speed and ionization energy loss $(dE/dx)$ inconsistent with muons produced in beam collisions. CMLLPs are predicted in several theories of physics beyond the standard model. We exclude pair-produced long-lived gaugino-like charginos below 267 GeV and higgsino-like charginos below 217 GeV at 95% C.L., as well as long-lived scalar top quarks with mass below 285 GeV.

Particle physicsPhysics beyond the Standard ModelTevatronFOS: Physical sciencesGeneral Physics and Astronomy01 natural sciencesHigh Energy Physics - ExperimentStandard Modellaw.inventionNuclear physicsHigh Energy Physics - Experiment (hep-ex)law0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Fermilab010306 general physicsColliderPhysicsMuonLuminosity (scattering theory)010308 nuclear & particles physicsHigh Energy Physics::PhenomenologyParticle acceleratorExperimental High Energy PhysicsPhysics::Accelerator PhysicsHigh Energy Physics::Experiment
researchProduct

Sensitivity of alanine dosimeters with gadolinium exposed to 6 MV photons at clinical doses.

2011

In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on …

PhotonESR dosimetryGadoliniumMonte Carlo methodAccelerationBiophysicschemistry.chemical_elementGadoliniumLinear particle acceleratorRadiology Nuclear Medicine and imagingIrradiationRadiometryMonte Carlo simulationAlaninePhotonsRadiationDosimeterAlanineChemistryX-RaysRadiochemistryElectron Spin Resonance SpectroscopyDose-Response Relationship RadiationSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Alanine dosimeters gadoliniumLinear ModelsSensitivity (electronics)Monte Carlo MethodRadiation research
researchProduct

Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.

2009

Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…

PhotonMonte Carlo methodBiophysicsRadiation DosageLinear particle acceleratorlaw.inventionIonlawDosimetryHumansScattering RadiationRadiology Nuclear Medicine and imagingPhysicsIonsPhotonsRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-AssistedReproducibility of ResultsWaterParticle acceleratorCharged particleIonization chamberRadiotherapy Intensity-ModulatedAtomic physicsParticle AcceleratorsMonte Carlo MethodAlgorithmsZeitschrift fur medizinische Physik
researchProduct

Innovative remotely-controlled bending device for thin silicon and germanium crystals

2020

Steering of negatively charged particle beams below 1 GeV has demonstrated to be possible with thin bent silicon and germanium crystals. A newly designed mechanical holder was used for bending crystals, since it allows a remotely-controlled adjustment of crystal bending and compensation of unwanted torsion. Bent crystals were installed and tested at the MAMI Mainz MIcrotron to achieve steering of 0.855-GeV electrons at different bending radii. We report the description and characterization of the innovative bending device developed at INFN Laboratori Nazionali di Legnaro (LNL).

Physics - Instrumentation and DetectorsMaterials scienceAccelerator ApplicationsSiliconBeam OpticsNegatively charged particleAccelerator Applications; Beam Optics; Instrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons); Instrumentation for particle accelerators and storage rings - lowenergy (linear accelerators cyclotrons electrostatic accelerators); Instrumentation; Mathematical PhysicsBent molecular geometryFOS: Physical scienceschemistry.chemical_elementGermaniumElectron01 natural sciencesInstrumentation for particle accelerators and storage rings - lowenergy (linear accelerators cyclotrons electrostatic accelerators)Instrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons)NOCrystal0103 physical sciencesNuclear Experiment010306 general physicsInstrumentationMicrotronMathematical Physics010308 nuclear & particles physicsbusiness.industryTorsion (mechanics)Instrumentation and Detectors (physics.ins-det)chemistryPhysics::Accelerator PhysicsOptoelectronicsbusinessJournal of Instrumentation
researchProduct

Photonuclear reactions with zinc: A case for clinical linacs

2015

WOS: 000365732300003

Physics - Instrumentation and DetectorsPhotonRAYGeneral Physics and AstronomyFOS: Physical sciencesNUCLEAR01 natural sciences7. Clean energyLinear particle acceleratorS-DALINACNuclear physicsNucleosynthesis0103 physical sciencesSCATTERINGFACILITYNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear ExperimentGA-67PhysicsNUCLEOSYNTHESIS010308 nuclear & particles physicsScatteringBremsstrahlungInstrumentation and Detectors (physics.ins-det)[0-Belirlenecek]3. Good healthPhysics::Accelerator PhysicsHpge detectorDECAYBremsstrahlung photonBeam (structure)
researchProduct

Reducing the contribution of the photoemission process to the unwanted beam in photoelectron sources at accelerators

2017

Negative electron affinity (NEA) GaAs photocathodes show different pulse responses depending on the wavelength of photoexcitation. The pulse response at 800 nm shows a long and relatively intense tail, whereas at 400 nm, a tail of similar shape but with an intensity lower by around two orders of magnitude is observed. We explain this behavior with the specific properties of NEA photocathodes and compare it with the response of a positive electron affinity photocathode.

Physics and Astronomy (miscellaneous)ChemistryParticle accelerator02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesPhotocathodelaw.inventionGallium arsenidePhotoexcitationWavelengthchemistry.chemical_compoundlawElectron affinity0103 physical sciencesAtomic physics010306 general physics0210 nano-technologyBeam (structure)Order of magnitudeApplied Physics Letters
researchProduct

A superconducting CW-LINAC for heavy ion acceleration at GSI

2017

The European physical journal / Web of Conferences 138, 01026 (2017). doi:10.1051/epjconf/201713801026

Physics010308 nuclear & particles physicsbusiness.industryNuclear engineeringPhysicsQC1-999Electrical engineeringCoulomb barrierInjector01 natural sciences530Linear particle acceleratorlaw.inventionAccelerationDuty cyclelawUniversal linear accelerator0103 physical sciencesContinuous waveddc:530010306 general physicsbusinessBeam (structure)
researchProduct

First Capture of Antiprotons in a Penning Trap: A Kiloelectronvolt Source

1986

Antiprotons from the Low Energy Antiproton Ring of CERN are slowed from 21 MeV to below 3 keV by being passed through 3 mm of material, mostly Be. While still in flight, the kiloelectronvolt antiprotons are captured in a Penning trap created by the sudden application of a 3-kV potential. Antiprotons are held for 100 s and more. Prospects are now excellent for much longer trapping times under better vacuum conditions. This demonstrates the feasibility of a greatly improved measurement of the inertial mass of the antiproton and opens the way to other intriguing experiments.

PhysicsAntiparticleLarge Hadron ColliderGeneral Physics and AstronomyParticle acceleratorPenning trapKinetic energylaw.inventionNuclear physicslawAntiprotonAntimatterKiloelectronvoltPhysics::Accelerator PhysicsHigh Energy Physics::ExperimentPhysics::Atomic PhysicsDetectors and Experimental TechniquesAtomic physicsNuclear ExperimentPhysical Review Letters
researchProduct

Current status and future plans for the general antiparticle spectrometer (GAPS)

2008

著者人数: 13名

PhysicsAtmospheric ScienceParticle physicsAntiparticleSpectrometerAstrophysics::High Energy Astrophysical PhenomenaDark matterAerospace EngineeringAstronomy and AstrophysicsCosmic rayParticle acceleratorlaw.inventionNuclear physicsGeophysicsPionSpace and Planetary SciencelawGeneral Earth and Planetary SciencesCurrent (fluid)Nuclear ExperimentExotic atomAdvances in Space Research
researchProduct

IBSIMU: a three-dimensional simulation software for charged particle optics.

2010

A general-purpose three-dimensional (3D) simulation code IBSIMU for charged particle optics with space charge is under development at JYFL. The code was originally developed for designing a slit-beam plasma extraction and nanosecond scale chopping for pulsed neutron generator, but has been developed further and has been used for many applications. The code features a nonlinear FDM Poisson's equation solver based on fast stabilized biconjugate gradient method with ILU0 preconditioner for solving electrostatic fields. A generally accepted nonlinear plasma model is used for plasma extraction. Magnetic fields can be imported to the simulations from other programs. The particle trajectories are …

PhysicsBiconjugate gradient methodbusiness.industryCyclotronParticle acceleratorPlasmaSolverCharged particlelaw.inventionOpticsNeutron generatorPhysics::Plasma PhysicslawPoisson's equationbusinessInstrumentationThe Review of scientific instruments
researchProduct