Search results for "Particle accelerator"
showing 10 items of 180 documents
Search for charged massive long-lived particles
2012
We report on a search for charged massive long-lived particles (CMLLPs), based on 5.2 fb$^{-1}$ of integrated luminosity collected with the D0 detector at the Fermilab Tevatron $p\bar{p}$ collider. We search for events in which one or more particles are reconstructed as muons but have speed and ionization energy loss $(dE/dx)$ inconsistent with muons produced in beam collisions. CMLLPs are predicted in several theories of physics beyond the standard model. We exclude pair-produced long-lived gaugino-like charginos below 267 GeV and higgsino-like charginos below 217 GeV at 95% C.L., as well as long-lived scalar top quarks with mass below 285 GeV.
Sensitivity of alanine dosimeters with gadolinium exposed to 6 MV photons at clinical doses.
2011
In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on …
Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.
2009
Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…
Innovative remotely-controlled bending device for thin silicon and germanium crystals
2020
Steering of negatively charged particle beams below 1 GeV has demonstrated to be possible with thin bent silicon and germanium crystals. A newly designed mechanical holder was used for bending crystals, since it allows a remotely-controlled adjustment of crystal bending and compensation of unwanted torsion. Bent crystals were installed and tested at the MAMI Mainz MIcrotron to achieve steering of 0.855-GeV electrons at different bending radii. We report the description and characterization of the innovative bending device developed at INFN Laboratori Nazionali di Legnaro (LNL).
Photonuclear reactions with zinc: A case for clinical linacs
2015
WOS: 000365732300003
Reducing the contribution of the photoemission process to the unwanted beam in photoelectron sources at accelerators
2017
Negative electron affinity (NEA) GaAs photocathodes show different pulse responses depending on the wavelength of photoexcitation. The pulse response at 800 nm shows a long and relatively intense tail, whereas at 400 nm, a tail of similar shape but with an intensity lower by around two orders of magnitude is observed. We explain this behavior with the specific properties of NEA photocathodes and compare it with the response of a positive electron affinity photocathode.
A superconducting CW-LINAC for heavy ion acceleration at GSI
2017
The European physical journal / Web of Conferences 138, 01026 (2017). doi:10.1051/epjconf/201713801026
First Capture of Antiprotons in a Penning Trap: A Kiloelectronvolt Source
1986
Antiprotons from the Low Energy Antiproton Ring of CERN are slowed from 21 MeV to below 3 keV by being passed through 3 mm of material, mostly Be. While still in flight, the kiloelectronvolt antiprotons are captured in a Penning trap created by the sudden application of a 3-kV potential. Antiprotons are held for 100 s and more. Prospects are now excellent for much longer trapping times under better vacuum conditions. This demonstrates the feasibility of a greatly improved measurement of the inertial mass of the antiproton and opens the way to other intriguing experiments.
Current status and future plans for the general antiparticle spectrometer (GAPS)
2008
著者人数: 13名
IBSIMU: a three-dimensional simulation software for charged particle optics.
2010
A general-purpose three-dimensional (3D) simulation code IBSIMU for charged particle optics with space charge is under development at JYFL. The code was originally developed for designing a slit-beam plasma extraction and nanosecond scale chopping for pulsed neutron generator, but has been developed further and has been used for many applications. The code features a nonlinear FDM Poisson's equation solver based on fast stabilized biconjugate gradient method with ILU0 preconditioner for solving electrostatic fields. A generally accepted nonlinear plasma model is used for plasma extraction. Magnetic fields can be imported to the simulations from other programs. The particle trajectories are …