First results from electrical qualification measurements on DEPFET pixel detector
2010
We report on the first results from a new setup for electrical qualification measurements of DEPFET pixel detector matrices. In order to measure the transistor properties of all pixels, the DEPFET device is placed into a benchtest setup and electrically contacted via a probecard. Using a switch matrix, each pixel of the detector array can be addressed individually for characterization. These measurements facilitate to pre-select the best DEPFET matrices as detector device prior to the mounting of the matrix and allow to investigate topics like the homogeneity of transistor parameters on device, wafer and batch level in order to learn about the stability and reproducibility of the production…
Dark Matter Results from 100 Live Days of XENON100 Data
2011
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interact…
Erratum: Search for Light Dark Matter in XENON10 Data [Phys. Rev. Lett.107, 051301 (2011)]
2013
Measurement of fission products β decay properties using a total absorption spectrometer
2013
In a nuclear reactor, the decay of fission fragments is at the origin of decay heat and antineutrino flux. These quantities are not well known while they are very important for reactor safety and for our understanding of neutrino physics. One reason for the discrepancies observed in the estimation of the decay heat and antineutrinos flux coming from reactors could be linked with the Pandemonium effect. New measurements have been performed at the JYFL facility of Jyvaskyla with a Total Absorption Spectrometer (TAS) in order to circumvent this effect. An overview of the TAS technique and first results from the 2009 measurement campaign will be presented. © Owned by the authors, published by E…
Locust: C++ software for simulation of RF detection
2019
The Locust simulation package is a new C++ software tool developed to simulate the measurement of time-varying electromagnetic fields using RF detection techniques. Modularity and flexibility allow for arbitrary input signals, while concurrently supporting tight integration with physics-based simulations as input. External signals driven by the Kassiopeia particle tracking package are discussed, demonstrating conditional feedback between Locust and Kassiopeia during software execution. An application of the simulation to the Project 8 experiment is described. Locust is publicly available at https://github.com/project8/locust_mc.
ALEPH: a Detector for Electron-Positron Annihilations at LEP
1990
Process-centred Software Engineering Environments (PSEE) are the most recent generation of environments supporting software development activities. Most of PSEE are based on mechanisms promoting enforcement and automation of process activities. In this kind of mechanisms the process models are prescribed in a detailed and complete way. But the experience shows that supporting processes is more concerned with the flexibility of guidance offered during the process performance than with enforcement of a collection of predefined process models. In this paper, we present a solution to support strategic processes in a PSEE by providing a flexible guidance during process enactment.
The T[sub z] = −1→ T[sub z] =0 beta decays and comparison with Charge Exchange reactions
2011
Gamow‐Teller (GT) transitions can be studied in both β decay and charge exchange (CE) reactions. If isospin is a good quantum number, then the Tz = −1→0 and Tz = +1→0 GT mirror transitions, are identical. Therefore, a comparison of the results from studies of β decay and CE should shed light on this assumption. Accordingly we have studied the β decay of the Tz = −1 fp‐shell nuclei, 54Ni, 50Fe, 46Cr, and 42Ti, produced in fragmentation and we have compared our results with the spectra from (3He, t) measurements on the mirror Tz = +1 target nuclei studied in high resolution at RCNP, Osaka. The β decay experiments were performed as part of the STOPPED beam RISING campaign at GSI.
Performance study of the fast timing Cherenkov detector based on a microchannel plate PMT
2017
Prototype of the fast timing Cherenkov detector, applicable in high-energy collider experiments, has been developed basing on the modified Planacon XP85012 MCP-PMT and fused silica radiators. We present the reasons and description of the MCP-PMT modification, timing and amplitude characteristics of the prototype including the summary of the detector's response on particle hits at oblique angles and MCP-PMT performance at high illumination rates.
Test and Simulation of a LYSO+APD matrix with a tagged Photon Beam from 40 to 300 MeV
2012
Understanding the energy resolution terms for LYSO based calorimeters with APD readout at low energy (< 500 MeV) is relevant both for the completion of the KLOE-2 experiment, at DAΦNE, and for the design of the Mu2e calorimeter. In this work, we present a dedicated comparison between experimental data, taken in 2011 at the MAMI tagged photon beam facility with a crystal matrix prototype, and a full Geant-4 simulation of this detector. The crystal prototype matrix consisted of 9 2×2 × 15 cm3 LYSO crystals read-out by 10×10 mm2 Hamamatsu avalanche photodiodes (APD) surrounded by 8 PbWO4 crystals read-out by Bialkali photomultipliers for outer leakage recovery granting a total transverse cover…
Determination of the B(E3, 0+ → 3−)-excitation strength in octupole-correlated nuclei near A ≈224 by the means of Coulomb excitation at REX-ISOLDE
2013
The IS475 collaboration conducted Coulomb-excitation experiments with postaccelerated radioactive 220Rn and 224Ra beams at the REX-ISOLDE facility. The beam particles (Ebeam ≈ 2.83 MeV/u) were Coulomb excited using 60Ni, 114Cd, and 120Sn scattering targets. De-excitation γ-rays were detected employing the Miniball array and scattered particles were detected in a silicon detector. Exploiting the Coulomb-excitation code GOSIA for each nucleus several matrix elements could be obtained from the measured γ-ray yields. The extracted 3−||Ê3||0+ matrix element allows for the conclusion that, while 220Rn represents an octupole vibrational system, 224Ra has already substantial octupole correlations i…