Search results for "Permeability"

showing 10 items of 596 documents

Hyaluronic Acid-Based Micelles as Ocular Platform to Modulate the Loading, Release, and Corneal Permeation of Corticosteroids

2017

The aim of this work is to prepare hyaluronic acid-based micelles as a platform to load corticosteroid drugs and to improve their corneal permeation after administration on the ocular surface. Three amphiphilic derivatives of hyaluronic acid (HA) are synthesized using different amounts of hexadecylamine (C16 -NH2 ). HAC16 a, HAC16 b, and HAC16 c derivatives are able to form micelles by the cosolvent evaporation method and to entrap corticosteroids (dexamethasone, triamcinolone, triamcinolone acetonide). HAC16 a and HAC16 b micelles show the best results in terms of drug loading and particle size. They are also able to improve drug release compared to free drug solution or suspension. In add…

Materials Chemistry2506 Metals and AlloysTriamcinolone acetonidePolymers and PlasticsAdministration Ophthalmic02 engineering and technologyTriamcinolone01 natural sciencesMicelleDexamethasoneCorneachemistry.chemical_compoundDrug Delivery SystemsAdrenal Cortex HormonesHyaluronic acidMaterials ChemistryCorticosteroidAminesCells CulturedMicellesDrug CarriersChemistryPermeation021001 nanoscience & nanotechnology0210 nano-technologyDrug carriermedicine.drugBiotechnologyTranscorneal enhancerHyaluronic acidBioengineering010402 general chemistryPermeabilityBiomaterialsPolymeric micelleAmphiphilemedicineMucoadhesionAnimalsHumansGlucocorticoidsPolymers and PlasticOcular administrationBiomaterialHydrocarbons0104 chemical sciencesDrug LiberationSettore CHIM/09 - Farmaceutico Tecnologico ApplicativoBiophysicsCattleEx vivo
researchProduct

Characterization of the Altered Zone Around a Fracture in Palmottu Natural Analogue

1996

AbstractA drill core sample penetrating at a natural fracture has been analysed by helium gas techniques and by α-autoradiography. Porosity and diffusivity profiles away from the fracture have been determined and compared with structural profiles. Model calculations are used to determine the effects of sample size on the measured porosities and diffusivities.

Materials science010504 meteorology & atmospheric sciences0207 environmental engineeringCore sampleMineralogy02 engineering and technologyThermal diffusivity01 natural sciencesPetroleum reservoirPermeability (earth sciences)Mass transferFracture (geology)020701 environmental engineeringPorosity0105 earth and related environmental sciencesWaste disposalMRS Proceedings
researchProduct

Soils with Specific Features

2016

This chapter deals with some specific features of soil that are relevant for interpretation of infiltration experiments. Infiltration in water repellent soils is first examined. After summarizing the causes of hydrophobicity, phenomena associated to infiltration in water repellent soil, including reduced infiltration rates and irregular wetting front advance, are illustrated. The Water Drop Penetration Time (WDPT), the Molarity of an Ethanol Droplet (MED) and the Repellency tests for quantitative assessment of soil water repellency are presented. Particular attention is given to estimation of subcritical soil water repellency by means of soil sorptivity measurements conducted with infiltrat…

Materials science010504 meteorology & atmospheric sciencesMacroporeSorptivityWater flowSoil science04 agricultural and veterinary sciences01 natural sciencesPermeability (earth sciences)Infiltration (hydrology)Hydraulic conductivitySoil water040103 agronomy & agriculture0401 agriculture forestry and fisheriesInfiltrometer0105 earth and related environmental sciences
researchProduct

Fracture flow due to hydrothermally induced quartz growth

2017

Abstract Mineral precipitations are a common feature and limitation of initially open, permeable rock fractures by forming sealing structures or secondary roughness in open voids. Hence, the objective of this numerical study is the evaluation of hydraulic properties of fractures sealed by hydrothermally induced needle and compact quartz growth. Phase-field models of progressive syntaxial and idiomorphic quartz growth are implemented into a fluid flow simulation solving the Navier–Stokes equation. Flow simulations for both quartz types indicate an obvious correlation between changes in permeability, fracture properties (e.g. aperture, relative roughness and porosity) and crystal growth behav…

Materials science010504 meteorology & atmospheric sciencesMineralogyCrystal growthSurface finish010502 geochemistry & geophysicsFracture flow01 natural sciencesPermeability (earth sciences)Fluid dynamicsComposite materialPorosityPorous mediumQuartz0105 earth and related environmental sciencesWater Science and TechnologyAdvances in Water Resources
researchProduct

Gas Barrier, Rheological and Mechanical Properties of Immiscible Natural Rubber/Acrylonitrile Butadiene Rubber/Organoclay (NR/NBR/Organoclay) Blend N…

2020

In this paper, gas permeability studies were performed on materials based on natural rubber/acrylonitrile butadiene rubber blends and nanoclay incorporated blend systems. The properties of natural rubber (NR)/nitrile rubber (NBR)/nanoclay nanocomposites, with a particular focus on gas permeability, are presented. The measurements of the barrier properties were assessed using two different gases—O2 and CO2—by taking in account the blend composition, the filler loading and the nature of the gas molecules. The obtained data showed that the permeability of gas transport was strongly affected by: (i) the blend composition—it was observed that the increase in acrylonitrile butadiene rubber compon…

Materials science02 engineering and technology010402 general chemistry01 natural scienceslcsh:Technologychemistry.chemical_compound[SPI]Engineering Sciences [physics]Natural rubberOrganoclayGeneral Materials ScienceNitrile rubberlcsh:Microscopylcsh:QC120-168.85Nanocompositelcsh:QH201-278.5lcsh:TCommunicationPermeationpolymer blend021001 nanoscience & nanotechnology0104 chemical sciencesnanoclaychemistryChemical engineeringPermeability (electromagnetism)lcsh:TA1-2040visual_artvisual_art.visual_art_mediumlcsh:Descriptive and experimental mechanicsPolymer blendnanoclay.lcsh:Electrical engineering. Electronics. Nuclear engineeringgas permeabilityAcrylonitrile0210 nano-technologylcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971
researchProduct

Characterization of Different Cable Ferrite Materials to Reduce the Electromagnetic Noise in the 2–150 kHz Frequency Range

2018

The gap of standardization for conducted and field coupled electromagnetic interferences (EMI) in the 2–150 kHz frequency range can lead to Electromagnetic Compatibility (EMC) problems. This is caused by power systems such as Pulse Width Modulation (PWM) controlled rectifiers, photovoltaic inverters or charging battery units in electric vehicles. This is a very important frequency spectral due to interferences generated in a wide range of devices and, specifically, communication problems in the new technologies and devices incorporated to the traditional grid to convert it into a Smart Grid. Consequently, it is necessary to provide new solutions to attenuate this kind of interference, which…

Materials scienceAcoustics02 engineering and technology01 natural scienceslcsh:TechnologyArticlelow frequency emissionsElectric power systeminsertion lossEMI0103 physical sciencescable ferriteInsertion lossGeneral Materials Sciencelcsh:MicroscopyElectrical impedancelcsh:QC120-168.85010302 applied physicscable ferrite; electromagnetic interferences; low frequency emissions; nanocrystalline; relative permeability; insertion losselectromagnetic interferenceslcsh:QH201-278.5lcsh:TPhotovoltaic systemElectromagnetic compatibilityrelative permeability021001 nanoscience & nanotechnologylcsh:TA1-2040Ferrite (magnet)lcsh:Descriptive and experimental mechanicsnanocrystallinelcsh:Electrical engineering. Electronics. Nuclear engineering0210 nano-technologylcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971Pulse-width modulationMaterials; Volume 11; Issue 2; Pages: 174
researchProduct

Effect of media composition on long-term in vitro stability of barium alginate and polyacrylic acid multilayer microcapsules.

2000

For a number of applications stability of microcapsules is a critical factor. Since the maintenance of polyelectrolyte complexes depends considerably on the ion composition we tested the physical properties of barium alginate capsules and searched for conditions to improve stability by a multilayer coating with polyethylenimine (PEI) and polyacrylic acid (PAA). Mechanical stability and diameters were determined in barium alginate capsules and compared with multilayer capsules. Multilayer coating resulted in smaller capsules than barium complexing alone. The difference was more pronounced when CaCl2 was used instead of NaCl during coating. Barium alginate capsules and application of CaCl2 du…

Materials scienceAlginatesBiophysicsAcrylic Resinschemistry.chemical_elementBioengineeringBiocompatible MaterialsCapsulesengineering.materialPermeabilityBiomaterialschemistry.chemical_compoundCoatingCoated Materials BiocompatibleDrug StabilityPolymer chemistrySodium citratePolyethyleneiminePolyethyleniminePolyacrylic acidCapsuleBariumPolyelectrolyteCulture MediachemistryChemical engineeringDistilled waterMechanics of MaterialsCeramics and CompositesengineeringStress MechanicalBiomaterials
researchProduct

Permeability measurements in cobalt ferrite and carbonyl iron powders and suspensions

2002

Abstract Magnetic permeability data of cobalt ferrite and carbonyl iron suspensions are discussed. Using an induction method, the relative differential permeability, μr,dif, was measured as a function of the internal magnetic field for different volume fractions of the solid phase. In the case of cobalt ferrite suspensions, the μr,dif−H curve was obtained for a first increasing ramp of magnetic field (data series “1”), a decreasing ramp (data series “2”), and the second increasing one (data series “3”). Series “1” showed a maximum in the μr,dif−H trend that did not appear in series “2” and “3”. Furthermore, the data in series “2” and “3” are always below those in series “1”. The latter beha…

Materials scienceAnalytical chemistryEpoxyCondensed Matter PhysicsElastomerMagnetic hysteresisElectronic Optical and Magnetic MaterialsMagnetic fieldCarbonyl ironNuclear magnetic resonancePermeability (electromagnetism)visual_artMagnetorheological fluidvisual_art.visual_art_mediumMagnetic nanoparticlesJournal of Magnetism and Magnetic Materials
researchProduct

Preparation of three-layered porous PLA/PEG scaffold: relationship between morphology, mechanical behavior and cell permeability.

2015

Interface tissue engineering (ITE) is used to repair or regenerate interface living tissue such as for instance bone and cartilage. This kind of tissues present natural different properties from a biological and mechanical point of view. With the aim to imitating the natural gradient occurring in the bone-cartilage tissue, several technologies and methods have been proposed over recent years in order to develop polymeric functionally graded scaffolds (FGS). In this study three-layered scaffolds with a pore size gradient were developed by melt mixing polylactic acid (PLA) and two water-soluble porogen agents: sodium chloride (NaCl) and polyethylene glycol (PEG). Pore dimensions were controll…

Materials scienceBone RegenerationCell SurvivalPolymersParticulate leachingPolyestersBiomedical EngineeringBiocompatible Materials02 engineering and technologyPolyethylene glycol010402 general chemistry01 natural sciencesPermeabilityCell LinePolyethylene GlycolsBiomaterialschemistry.chemical_compoundMicePolylactic acidTissue engineeringMelt mixingPEG ratioAnimalsLactic AcidComposite materialBone regenerationPorosityCell ProliferationMechanical Phenomenachemistry.chemical_classificationTissue ScaffoldsInterface tissue engineeringPore size gradientAdhesivenessWaterFunctionally graded scaffoldPolymerPermeation021001 nanoscience & nanotechnologyBiomaterial0104 chemical sciencesSettore ING-IND/22 - Scienza E Tecnologia Dei MaterialichemistrySolubilityMechanics of Materials0210 nano-technologyPorosityJournal of the mechanical behavior of biomedical materials
researchProduct

Development and evaluation of occlusive systems employing polyvinyl alcohol for transdermal delivery of sumatriptan succinate

2010

The aim of the present study was to develop a sumatriptan succinate transdermal system for applying migraine treatments efficiently and easily. For this system polyvinyl alcohol was employed as a matrix and Azone((R)) was added as a permeability enhancer. The physical characteristics, mechanical properties, and in vivo bioadhesion of the systems were evaluated, as was in vitro permeation across porcine skin. A uniform distribution of the drug in the matrix was observed, and moisture uptake values were constant. With regard to mechanical parameters, occlusive layer inclusion made the system more resistant, and no significant differences were detected with respect to other systems. Although A…

Materials scienceChemistry PharmaceuticalDrug CompoundingMigraine DisordersSkin AbsorptionPharmaceutical SciencePharmacologyAdministration CutaneousPolyvinyl alcoholPermeabilitychemistry.chemical_compoundDrug Delivery SystemsDrug StabilityIn vivoSumatriptan SuccinatemedicineTechnology PharmaceuticalVasoconstrictor AgentsDrug InteractionsAntihypertensive AgentsTransdermalDrug CarriersSumatriptanAzepinesGeneral MedicineHydrogen-Ion ConcentrationPermeationSerotonin Receptor AgonistsSumatriptanSolubilitychemistryPermeability (electromagnetism)Polyvinyl AlcoholPolyvinylsAzoneBiomedical engineeringmedicine.drugDrug Delivery
researchProduct