Measuring guided waves in long bones: Modeling and experiments in free and immersed plates

2005

Guided waves, consistent with the A0 Lamb mode, have previously been observed in bone phantoms and human long bones. Reported velocity measurements relied on line fitting of the observed wave fronts. Such an approach has limited ability to assess dispersion and is affected by interference by other wave modes. For a more robust identification of modes and determination of phase velocities, signal processing techniques using the fast Fourier transform (FFT) were investigated. The limitations of FFT because of spatial resolution were addressed to improve the precision of the measured modes. An inversion scheme was developed for determining the plate thickness from the measured velocity. Experi…

Materials scienceAcoustics and UltrasonicsLine fittingAcousticsFast Fourier transformBiophysicsModels BiologicalBone and BonesImaging phantomsymbols.namesakeOpticsmedicineHumansRadiology Nuclear Medicine and imagingImage resolutionUltrasonographySignal processingFourier AnalysisRadiological and Ultrasound TechnologyPhantoms Imagingbusiness.industrySignal Processing Computer-AssistedAcousticsmedicine.anatomical_structureFourier analysissymbolsGroup velocityCortical bonebusinessUltrasound in Medicine & Biology
researchProduct

Study of smartphone suitability for mapping of skin chromophores.

2015

RGB (red-green-blue) technique for mapping skin chromophores by smartphones is proposed and studied. Three smartphones of different manufacturers were tested on skin phantoms and in vivo on benign skin lesions using a specially designed light source for illumination. Hemoglobin and melanin indices obtained by these smartphones showed differences in both tests. In vitro tests showed an increment of hemoglobin and melanin indices with the concentration of chromophores in phantoms. In vivo tests indicated higher hemoglobin index in hemangiomas than in nevi and healthy skin, and nevi showed higher melanin index compared to the healthy skin. Smartphones that allow switching off the automatic cam…

Materials scienceBiomedical EngineeringSkin PigmentationIn vivo testsSkin DiseasesBiomaterialsMelaninOpticsOptical imagingLight sourcemedicineImage Processing Computer-AssistedNevusHumansNevusSkinintegumentary systembusiness.industryPhantoms ImagingOptical Imagingmedicine.diseaseAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSmartphoneSkin lesionbusinessHemangiomaAlgorithmsBiomedical engineeringJournal of biomedical optics
researchProduct

Poor optical stability of molecular dyes when used as absorbers in water-based tissue-simulating phantoms

2019

Biomedical optical systems and models can be easily validated by the use of tissue-simulating phantoms. They can consist of water-based turbid media which often include inks (India ink and molecular dyes) as absorbers. Optical stability of commonly exploited inks under the influence of light, pH changes and the addition of TiO2 and surfactant, was studied. We found that the exposure to ultraviolet and visible light can crucially affect the absorption properties of molecular dyes. On average, absorption peaks decreased by 47.3% in 150 exposure hours. Furthermore, dilution can affect ink’s pH and by that, its decay rate under light exposure. When TiO2 was added to the phantoms, all molecular …

Materials sciencesurfactantturbid media02 engineering and technologymedicine.disease_cause01 natural sciencesIndia ink010309 opticsPulmonary surfactant0103 physical sciencesmedicinetissue-simulating phantomsmolecular dyesoptical spectroscopySpectroscopyAbsorption (electromagnetic radiation)Inkwell021001 nanoscience & nanotechnology3. Good healthDilutionoptical stabilityChemical engineering:NATURAL SCIENCES::Physics::Atomic and molecular physics [Research Subject Categories]Photocatalysis0210 nano-technologyUltravioletVisible spectrum
researchProduct

A human post-mortem brain model for the standardization of multi-centre MRI studies

2015

Multi-centre MRI studies of the brain are essential for enrolling large and diverse patient cohorts, as required for the investigation of heterogeneous neurological and psychiatric diseases. However, the multi-site comparison of standard MRI data sets that are weighted with respect to tissue parameters such as the relaxation times (T1, T2) and proton density (PD) may be problematic, as signal intensities and image contrasts depend on site-specific details such as the sequences used, imaging parameters, and sensitivity profiles of the radiofrequency (RF) coils. Water or gel phantoms are frequently used for long-term and/or inter-site quality assessment. However, these phantoms hardly mimic t…

Models Anatomicmedicine.medical_specialtyNeurologyCognitive NeuroscienceModels NeurologicalMulti-centre MRI studies; Post-mortem brain; Quantitative MRI; Standardization; Aged; Artifacts; Brain; Female; Humans; Magnetic Resonance Imaging; Multicenter Studies as Topic; Phantoms Imaging; Reproducibility of Results; Models Anatomic; Models Neurological; Postmortem Changes; Cognitive Neuroscience; Neurology; Medicine (all)Cognitive neuroscienceImaging phantomPhantomsImagingWhite matterModelsPost-mortem brainmedicineHumansMulticenter Studies as TopicMagnetization transferMulti-centre MRI studiesAgedmedicine.diagnostic_testbusiness.industryPhantoms ImagingMedicine (all)AnatomicBrainReproducibility of ResultsMagnetic resonance imagingHuman brainQuantitative MRIMagnetic Resonance ImagingStandardizationmedicine.anatomical_structureNeurologyPostmortem ChangesNeurologicalFemaleBrainstemNuclear medicinebusinessArtifacts
researchProduct

Dose determination using alanine detectors in a mixed neutron and gamma field for boron neutron capture therapy of liver malignancies

2011

IntroductionBoron Neutron Capture Therapy for liver malignancies is being investigated at the University of Mainz. One important aim is the set-up of a reliable dosimetry system. Alanine dosimeters have previously been applied for dosimetry of mixed radiation fields in antiproton therapy, and may be suitable for measurements in mixed neutron and gamma fields.Materials and MethodsTwo experiments have been carried out in the thermal column of the TRIGA Mark II reactor at the University of Mainz. Alanine dosimeters have been irradiated in a phantom and in liver tissue.ResultsFor the interpretation and prediction of the dose for each pellet, beside the results of the measurements, calculations …

Monte Carlo methodBoron Neutron Capture TherapyImaging phantomTRIGAIonizing radiationRadiation MonitoringHumansMedicineDosimetryRadiology Nuclear Medicine and imagingNeutronRadiometryNeutronsAlanineDosimeterPhantoms Imagingbusiness.industryLiver NeoplasmsRadiochemistryDose-Response Relationship RadiationHematologyGeneral MedicineNeutron captureLiverOncologyGamma RaysbusinessNuclear medicineMonte Carlo MethodActa Oncologica
researchProduct

Optimal control design of preparation pulses for contrast optimization in MRI

2017

Abstract This work investigates the use of MRI radio-frequency (RF) pulses designed within the framework of optimal control theory for image contrast optimization. The magnetization evolution is modeled with Bloch equations, which defines a dynamic system that can be controlled via the application of the Pontryagin Maximum Principle (PMP). This framework allows the computation of optimal RF pulses that bring the magnetization to a given state to obtain the desired contrast after acquisition. Creating contrast through the optimal manipulation of Bloch equations is a new way of handling contrast in MRI, which can explore the theoretical limits of the system. Simulation experiments carried out…

Nuclear and High Energy PhysicsComputer science[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingComputationRF pulsesBiophysics010402 general chemistry01 natural sciencesBiochemistry030218 nuclear medicine & medical imaging03 medical and health sciencesMagnetizationMice0302 clinical medicineOpticsRobustness (computer science)Image Interpretation Computer-AssistedImage Processing Computer-AssistedAnimalsComputer SimulationGray MatterMuscle Skeletal[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/Imagingbusiness.industryPhantoms ImagingContrast (statistics)BrainReproducibility of ResultsContrastCondensed Matter PhysicsOptimal controlImage EnhancementBloch equationsMagnetic Resonance ImagingWhite Matter0104 chemical sciencesWeightingRatsOptimal control[SPI.ELEC]Engineering Sciences [physics]/ElectromagnetismOptimal control designBloch equations[ SPI.ELEC ] Engineering Sciences [physics]/ElectromagnetismFemalebusinessAlgorithmAlgorithms
researchProduct

DNP in MRI: an in-bore approach at 1.5 T.

2011

Abstract We have used liquid state (“Overhauser”) Dynamic Nuclear Polarization (DNP) to significantly enhance the signal to noise ratio (SNR) of Magnetic Resonance Imaging (MRI). For the first time this was achieved by hyperpolarizing directly in the MRI-scanner field of 1.5 T in continuous flow mode and immediately delivering the hyperpolarized substance to the imaging site to ensure maximum contrast between hyperpolarized sample and sample at thermal polarization. We achieve a maximum absolute signal enhancement factor of 98; while the hyperpolarized sample is transported at a flow rate of up to 30 ml/h yielding an average flow speed up to 470 mm/s over a distance of approximately 80 mm. …

Nuclear and High Energy PhysicsContrast enhancementMagnetic Resonance Spectroscopymedicine.diagnostic_testContinuous flowChemistryPhantoms ImagingBiophysicsMagnetic resonance imagingSignal-To-Noise RatioCondensed Matter PhysicsPolarization (waves)BiochemistryMagnetic Resonance ImagingVolumetric flow rateSignal enhancementCyclic N-OxidesLiquid stateNuclear magnetic resonanceFlow velocitymedicineImage Processing Computer-AssistedSpin LabelsMicrowavesCopperJournal of magnetic resonance (San Diego, Calif. : 1997)
researchProduct

Mixture and dissolution of laser polarized noble gases: Spectroscopic and imaging applications

2012

Nuclear and High Energy PhysicsMagnetic Resonance SpectroscopyPhantoms ImagingSwineChemistryLasersAnalytical chemistryMolecular Dynamics SimulationLaserMagnetic Resonance ImagingNoble GasesBiochemistryAnalytical Chemistrylaw.inventionLaser polarizationlawSpin echoAnimalsHumansAtomic physicsDiffusion (business)SpectroscopyLungDissolutionSpectroscopyProgress in Nuclear Magnetic Resonance Spectroscopy
researchProduct

Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system.

2009

Abstract A technique for continuous production of solutions containing hyperpolarized 129Xe is explored for MRI applications. The method is based on hollow fiber membranes which inhibit the formation of foams and bubbles. A systematic analysis of various carrier agents for hyperpolarized 129Xe has been carried out, which are applicable as contrast agents for in vivo MRI. The image quality of different hyperpolarized Xe solutions is compared and MRI results obtained in a clinical as well as in a nonclinical MRI setting are provided. Moreover, we demonstrate the application of 129Xe contrast agents produced with our dissolution method for lung MRI by imaging hyperpolarized 129Xe that has been…

Nuclear and High Energy PhysicsPulmonary Circulationmedicine.diagnostic_testContinuous flowChemistryPhantoms ImagingBiophysicsLung perfusionMagnetic resonance imagingBiocompatible MaterialsMembranes ArtificialCondensed Matter PhysicsBiochemistryMagnetic Resonance ImagingImaging phantomSolutionsMembraneNuclear magnetic resonancemedicineImage Processing Computer-AssistedRespiratory MechanicsXenon IsotopesHyperpolarization (physics)LungJournal of magnetic resonance (San Diego, Calif. : 1997)
researchProduct

A fully automated method for accurate measurement of geometrical distortion in magnetic resonance imaging of a 3D-lattice phantom

2019

Abstract This paper describes an automated method for extracting the apparent positions of fiducial points from 2D or 3D images of a phantom. We consider a 3D-lattice phantom for two main reasons: first, ease of manufacture and isotropy of its structure with respect to coordinate projections; second, a connected structure allowing to uniquely assess the adjacency relationship between fiducial points even if geometric distortions arising from main magnet inhomogeneity and gradient fields non-linearity is severe as observed in open-bore systems. In order to validate our proposed method and compare different choices for the parameters of our phantom (i.e. number and distance between grids and …

Offset (computer science)RegistrationImage qualityComputer scienceBiomedical EngineeringBiophysicsImage enhancement/restoration (noise and artifact reduction)Signal-To-Noise RatioImaging phantomPattern Recognition Automated030218 nuclear medicine & medical imaging03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineSoftwareRobustness (computer science)HumansComputer SimulationRadiology Nuclear Medicine and imagingMagnetic resonance imaging (MRI)Fiducial point localizationElectronic Data ProcessingPhantoms ImagingSettore ING-INF/03 - Telecomunicazionibusiness.industryAirSpherical harmonicsModels TheoreticalMagnetic Resonance ImagingPhantom designPersonal computerAdjacency listbusinessAlgorithmSoftware030217 neurology & neurosurgeryMagnetic Resonance Imaging
researchProduct