Measuring guided waves in long bones: Modeling and experiments in free and immersed plates
2005
Guided waves, consistent with the A0 Lamb mode, have previously been observed in bone phantoms and human long bones. Reported velocity measurements relied on line fitting of the observed wave fronts. Such an approach has limited ability to assess dispersion and is affected by interference by other wave modes. For a more robust identification of modes and determination of phase velocities, signal processing techniques using the fast Fourier transform (FFT) were investigated. The limitations of FFT because of spatial resolution were addressed to improve the precision of the measured modes. An inversion scheme was developed for determining the plate thickness from the measured velocity. Experi…
Study of smartphone suitability for mapping of skin chromophores.
2015
RGB (red-green-blue) technique for mapping skin chromophores by smartphones is proposed and studied. Three smartphones of different manufacturers were tested on skin phantoms and in vivo on benign skin lesions using a specially designed light source for illumination. Hemoglobin and melanin indices obtained by these smartphones showed differences in both tests. In vitro tests showed an increment of hemoglobin and melanin indices with the concentration of chromophores in phantoms. In vivo tests indicated higher hemoglobin index in hemangiomas than in nevi and healthy skin, and nevi showed higher melanin index compared to the healthy skin. Smartphones that allow switching off the automatic cam…
Poor optical stability of molecular dyes when used as absorbers in water-based tissue-simulating phantoms
2019
Biomedical optical systems and models can be easily validated by the use of tissue-simulating phantoms. They can consist of water-based turbid media which often include inks (India ink and molecular dyes) as absorbers. Optical stability of commonly exploited inks under the influence of light, pH changes and the addition of TiO2 and surfactant, was studied. We found that the exposure to ultraviolet and visible light can crucially affect the absorption properties of molecular dyes. On average, absorption peaks decreased by 47.3% in 150 exposure hours. Furthermore, dilution can affect ink’s pH and by that, its decay rate under light exposure. When TiO2 was added to the phantoms, all molecular …
A human post-mortem brain model for the standardization of multi-centre MRI studies
2015
Multi-centre MRI studies of the brain are essential for enrolling large and diverse patient cohorts, as required for the investigation of heterogeneous neurological and psychiatric diseases. However, the multi-site comparison of standard MRI data sets that are weighted with respect to tissue parameters such as the relaxation times (T1, T2) and proton density (PD) may be problematic, as signal intensities and image contrasts depend on site-specific details such as the sequences used, imaging parameters, and sensitivity profiles of the radiofrequency (RF) coils. Water or gel phantoms are frequently used for long-term and/or inter-site quality assessment. However, these phantoms hardly mimic t…
Dose determination using alanine detectors in a mixed neutron and gamma field for boron neutron capture therapy of liver malignancies
2011
IntroductionBoron Neutron Capture Therapy for liver malignancies is being investigated at the University of Mainz. One important aim is the set-up of a reliable dosimetry system. Alanine dosimeters have previously been applied for dosimetry of mixed radiation fields in antiproton therapy, and may be suitable for measurements in mixed neutron and gamma fields.Materials and MethodsTwo experiments have been carried out in the thermal column of the TRIGA Mark II reactor at the University of Mainz. Alanine dosimeters have been irradiated in a phantom and in liver tissue.ResultsFor the interpretation and prediction of the dose for each pellet, beside the results of the measurements, calculations …
Optimal control design of preparation pulses for contrast optimization in MRI
2017
Abstract This work investigates the use of MRI radio-frequency (RF) pulses designed within the framework of optimal control theory for image contrast optimization. The magnetization evolution is modeled with Bloch equations, which defines a dynamic system that can be controlled via the application of the Pontryagin Maximum Principle (PMP). This framework allows the computation of optimal RF pulses that bring the magnetization to a given state to obtain the desired contrast after acquisition. Creating contrast through the optimal manipulation of Bloch equations is a new way of handling contrast in MRI, which can explore the theoretical limits of the system. Simulation experiments carried out…
DNP in MRI: an in-bore approach at 1.5 T.
2011
Abstract We have used liquid state (“Overhauser”) Dynamic Nuclear Polarization (DNP) to significantly enhance the signal to noise ratio (SNR) of Magnetic Resonance Imaging (MRI). For the first time this was achieved by hyperpolarizing directly in the MRI-scanner field of 1.5 T in continuous flow mode and immediately delivering the hyperpolarized substance to the imaging site to ensure maximum contrast between hyperpolarized sample and sample at thermal polarization. We achieve a maximum absolute signal enhancement factor of 98; while the hyperpolarized sample is transported at a flow rate of up to 30 ml/h yielding an average flow speed up to 470 mm/s over a distance of approximately 80 mm. …
Mixture and dissolution of laser polarized noble gases: Spectroscopic and imaging applications
2012
Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system.
2009
Abstract A technique for continuous production of solutions containing hyperpolarized 129Xe is explored for MRI applications. The method is based on hollow fiber membranes which inhibit the formation of foams and bubbles. A systematic analysis of various carrier agents for hyperpolarized 129Xe has been carried out, which are applicable as contrast agents for in vivo MRI. The image quality of different hyperpolarized Xe solutions is compared and MRI results obtained in a clinical as well as in a nonclinical MRI setting are provided. Moreover, we demonstrate the application of 129Xe contrast agents produced with our dissolution method for lung MRI by imaging hyperpolarized 129Xe that has been…
A fully automated method for accurate measurement of geometrical distortion in magnetic resonance imaging of a 3D-lattice phantom
2019
Abstract This paper describes an automated method for extracting the apparent positions of fiducial points from 2D or 3D images of a phantom. We consider a 3D-lattice phantom for two main reasons: first, ease of manufacture and isotropy of its structure with respect to coordinate projections; second, a connected structure allowing to uniquely assess the adjacency relationship between fiducial points even if geometric distortions arising from main magnet inhomogeneity and gradient fields non-linearity is severe as observed in open-bore systems. In order to validate our proposed method and compare different choices for the parameters of our phantom (i.e. number and distance between grids and …