Search results for "Photometry"

showing 10 items of 797 documents

Photoelectrocatalyzed degradation of a pesticides mixture solution (chlorfenvinphos and bromacil) by WO3 nanosheets

2019

[EN] A photoelectrocatalyst consisting of WO3 nanosheets or nanorods has been synthesized by electrochemical anodization under hydrodynamic conditions, and has been used for the degradation of two toxic pesticides: chlorfenvinphos and bromacil. Nanostructures have been characterized by FESEM and Raman spectroscopy. Photoelectrochemical degradation tests have been carried out both for individual pesticide solutions and for a mixture solution, and the concentration evolution with time has been followed by UV¿Vis spectrophotometry. For individual pesticides, pseudo-first order kinetic coefficients of 0.402 h¿1 and 0.324 h¿1 have been obtained for chlorfenvinphos and bromacil, respectively, whi…

Environmental Engineering010504 meteorology & atmospheric sciencesPhotoelectrochemistryElectrolyte010501 environmental sciences01 natural sciencesINGENIERIA QUIMICAsymbols.namesakechemistry.chemical_compoundPhotoelectrochemistryBromacilSpectrophotometrymedicineEnvironmental ChemistryWater treatmentPesticidesWaste Management and Disposal0105 earth and related environmental sciencesNanoestructuresmedicine.diagnostic_testChlorfenvinphosPollutionWO3 nanostructuresElectroquímicachemistryChemical engineeringsymbolsPesticide degradationDegradation (geology)Raman spectroscopy
researchProduct

Determination of mono-, di- and trinitronaphthalenes in soil samples contaminated by explosives.

2004

We investigated the extraction of eight mono-, di- and trinitronaphthalenes from soil samples by ultrasonic, respectively, soxhlet extraction. Sonication was the more convenient procedure with a usually higher repeatability than the soxhlet method. All extracts were analysed by high-performance liquid chromatography with diode array detection. These methods were used to determine the concentration of nitronaphthalenes in five soil samples polluted by explosives. The most abundant contaminants were 1,5- and 1,8-dinitronaphthalene as well as 1,3,5-, 1,3,8- and 1,4,5-trinitronaphthalene. In all samples the sum of trinitronaphthalenes exceeded the sum of mono- and dinitronaphthalenes. It is rec…

Environmental EngineeringChromatographySoil testChemistryHealth Toxicology and MutagenesisSonicationExtraction (chemistry)Public Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistryRepeatabilityHuman decontaminationContaminationNaphthalenesNitro CompoundsPollutionHigh-performance liquid chromatographySoil contaminationChemistry Techniques AnalyticalSonicationGermanyEnvironmental ChemistrySoil PollutantsSpectrophotometry UltravioletChromatography High Pressure LiquidChemosphere
researchProduct

Monitoring WWTP performance using size-exclusion chromatography with simultaneous UV and fluorescence detection to track recalcitrant wastewater frac…

2018

Abstract A trial monitoring of a typical full-scale municipal WWTP in Central Finland was aimed to explore applicability of high performance liquid chromatography – size exclusion chromatography (HPSEC) with simultaneous UV and fluorescence detection as a tool for advanced routine monitoring of wastewater treatment. High, intermediate, and low molecular weight (MW) fractions of untreated wastewater (influent) and treated wastewater (secondary effluent) were characterized in terms of UV absorbance at 254 nm (UVA254) and specific fluorescence representing tyrosine-like, tryptophan-like, and humic/fulvic-like compounds. The activated sludge treatment removed 97 ± 1% of BOD, 93 ± 2% of COD, 71 …

Environmental EngineeringHealth Toxicology and Mutagenesis0208 environmental biotechnologySize-exclusion chromatographyta117202 engineering and technologyjätevesiWastewater010501 environmental sciences01 natural sciencesHigh-performance liquid chromatographyWater Purificationwastewater characterizationWater SupplyEnvironmental ChemistryOrganic ChemicalsEffluentChromatography High Pressure LiquidFinlandActivated sludge system0105 earth and related environmental sciencesjäteveden käsittelyChromatographyChemistryPublic Health Environmental and Occupational HealthUV absorptionGeneral MedicineGeneral Chemistrymolecular weight distributionPollutionFluorescence020801 environmental engineeringsize-exclusion chromatographywastewater treatmentSpectrometry FluorescenceWastewaterChromatography GelMolar mass distributionSpectrophotometry UltravioletSewage treatmentfluorescenceWater Pollutants ChemicalEnvironmental MonitoringChemosphere
researchProduct

Determination and evaluation of cadmium, lead and nickel in greenhouse soils of Almerı́a (Spain)

2004

This study determines total levels of three (Cd, Pb and Ni) potentially toxic trace elements in western Almería (Spain) greenhouse surface soil horizons using microwave digestion; it establishes the geochemical baseline concentration, and it investigates possible relationships between soil properties and elemental concentrations. The results show that the soil concentration of these heavy metals is lower than mentioned in the European and Spanish normative, but they are higher than those reported by other authors working on agricultural soils. The obtained geochemical baseline concentrations (mg kg(-1)) were: Cd 0.4-0.8, Pb 2.5-89.9 and Ni 16.1-30.7. Using the upper baseline criterion, 88% …

Environmental EngineeringHealth Toxicology and Mutagenesischemistry.chemical_elementMetalSoilMetals HeavyEnvironmental ChemistryMicrowave digestionMicrowavesCadmiumSpectrophotometry AtomicPublic Health Environmental and Occupational HealthEnvironmental engineeringTrace elementAgricultureGeneral MedicineGeneral ChemistryEnvironment ControlledPollutionSoil contaminationNickelchemistrySpainEnvironmental chemistryvisual_artSoil watervisual_art.visual_art_mediumEnvironmental scienceSoil horizonChemosphere
researchProduct

Analysis of enantiomers giving partially overlapped peaks by using different treatments of the chromatographic ultraviolet signals: quantification of…

2001

Abstract Different strategies for the quantification of partially coeluting optical isomers have been investigated. The methods tested are based on the use of different features as the analytical UV signals: peak heights, perpendicular drop areas, first and second derivatives of the chromatograms, peak areas obtained by deconvolution of the overlapped peaks with data fitting optimization, and a multivariate model (principal component regression, PCR). The amphetamine-derivative drug pseudoephedrine was selected as a model compound. For chromatography, LiChrospher 100 RP 18 and a mobile-phase consisting of methanol and a solution of carboxymethyl-β-cyclodextrin (the chiral selector) were use…

EphedrineChromatographyChemistryOrganic ChemistryAnalytical chemistryStereoisomerismGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryNasal decongestantPrincipal component analysisCurve fittingPrincipal component regressionSpectrophotometry UltravioletEnantiomerSecond derivativeJournal of Chromatography A
researchProduct

Cysteine-Specific Radioiodination of Proteins with Fluorescein Maleimide

1997

A protocol is described for coupling of carrier-free iodine to protein sulfhydryl groups via fluorescein maleimide. 125I is first coupled to fluorescein maleimide in the presence of chloramine T. Iodination is stopped with sodium thiosulfate, and the iodine-substituted fluorescein maleimide is reacted with free cysteines of the protein. Excess label is then removed by gel-permeation chromatography. The procedure avoids exposition of the protein to oxidative conditions and does not require purification of the labeled carrier reagent. Suitability of the method for a given protein can be evaluated spectrophotometrically without employing radioactivity. It can be applied under denaturing condit…

ErythrocytesPolymersThiosulfatesBiophysicsPlasma protein bindingSodium thiosulfateComplement Hemolytic Activity AssaySensitivity and SpecificityBiochemistryIodine RadioisotopesTosyl Compoundschemistry.chemical_compoundBacterial ProteinsCysteineFluoresceinMolecular BiologyChloramineChromatographyChloraminesProteinsHalogenationCell BiologyFluoresceinsBiochemistrychemistrySpectrophotometryReagentStreptolysinsChromatography GelStreptolysinProtein BindingCysteineAnalytical Biochemistry
researchProduct

Taking Advantage of Selective Change Driven Processing for 3D Scanning

2013

This article deals with the application of the principles of SCD (Selective Change Driven) vision to 3D laser scanning. Two experimental sets have been implemented: one with a classical CMOS (Complementary Metal-Oxide Semiconductor) sensor, and the other one with a recently developed CMOS SCD sensor for comparative purposes, both using the technique known as Active Triangulation. An SCD sensor only delivers the pixels that have changed most, ordered by the magnitude of their change since their last readout. The 3D scanning method is based on the systematic search through the entire image to detect pixels that exceed a certain threshold, showing the SCD approach to be ideal for this applicat…

Event-based visionLaser scanningComputer scienceTransducers3d scanninglcsh:Chemical technologySensitivity and SpecificityBiochemistryArticleAnalytical Chemistrylaw.inventionPhotometryPhotometry (optics)Imaging Three-DimensionallawInformàticaNyquist–Shannon sampling theoremComputer visionlcsh:TP1-11853D scanningElectrical and Electronic Engineeringhigh-speed visual acquisitionInstrumentationPixelbusiness.industryLasers3D reconstructionReproducibility of ResultsSignal Processing Computer-AssistedEquipment DesignImage EnhancementLaserAtomic and Molecular Physics and OpticsEquipment Failure AnalysisTransducerSemiconductorsCMOSArtificial intelligencebusinessHigh-speed visual acquisitionevent-based visionSensors
researchProduct

Flecainide acetate acetic acid solvates.

2011

Flecainide acetate forms acetic acid solvates with 0.5 and 2 acetic acid molecules. Powder X-ray diffraction, differential thermal analysis/thermogravimetric, infrared, and potentiometric titration were used to determine the composition of solvates. Flecainide acetate hemisolvate with acetic acid decomposes to form a new crystalline form of flecainide acetate. This form is less stable than the already known polymorphic form at all temperatures, and it is formed due to kinetic reasons. Both flecainide acetate nonsolvated and flecainide acetate hemisolvate forms crystallize in monoclinic crystals, but flecainide triacetate forms triclinic crystals. Solvate formation was not observed when flec…

FlecainideSpectrophotometry InfraredChemistryFormic acidPotentiometric titrationPharmaceutical ScienceFlecainide AcetateMedicinal chemistryAcetic acidchemistry.chemical_compoundPropanoic acidPolymorphism (materials science)SolubilityX-Ray DiffractionThermogravimetrymedicinePotentiometrySolventsOrganic chemistryCrystallizationFlecainideAnti-Arrhythmia Agentsmedicine.drugMonoclinic crystal systemAcetic AcidJournal of pharmaceutical sciences
researchProduct

Flow-Injection Solid Phase Partial Least-Squares Spectrophotometric Simultaneous Determination of Iron, Nickel and Zinc

2002

A PLS-2 multivariate calibration method has been developed for the simultaneous determination of iron, nickel and zinc in ternary mixtures by solid phase spectrophotometry associated with flow injection analysis. Fe(II), Ni(II) and Zn(II) form color complexes with 1-(2-thiazolylazo)-2-naphthol (TAN), immobilized on a C18 bonded silica support, at pH 6.4. The proposed procedure is based on the different reaction/retention ratios of the studied ions on the solid support. Bilinear spectrophotometric data of the analytes, fixed in the solid support, were recorded in the 400-800 nm wavelength range as a function of time and a partial least squares (PLS-2) algorithm was used to predict results of…

Flow injection analysisAnalytemedicine.diagnostic_testAnalytical chemistrychemistry.chemical_elementGeneral ChemistryZincAbsorbanceNickelchemistrySpectrophotometryPartial least squares regressionmedicineTernary operationJournal of the Brazilian Chemical Society
researchProduct

Spectrophotometric and Fluorimetric Determination of 9-Amino Acridine by Flow Injection Analysis

1990

Abstract The spectrophotometric and fluorimetric determination of 9-amino acridine is carried out by means of the FIA procedures and on the basis of its own color or fluorescence. The methanol used as a carrier stream resulted in a significative increase in sensitivity and sample throughput. The method is applied to the drug determination in pharmaceutical formulations.

Flow injection analysisChromatographymedicine.diagnostic_testBiochemistry (medical)Clinical BiochemistryFluorescence spectrometryBiochemistryFluorescenceFluorescence spectroscopyDosage formAnalytical Chemistrychemistry.chemical_compoundchemistrySpectrophotometryAcridineElectrochemistrymedicineMethanolSpectroscopyAnalytical Letters
researchProduct