Search results for "Photometry"

showing 10 items of 797 documents

A Preliminary Estimation of the Direct Ultraviolet Spectral Irradiance in Valencia (Spain): Comparison with Measured Values

2000

UVSPEC and SMARTS2 models have been used to estimate the UV spectral irradiance values in Valencia, Spain, and the results of these estimations have been compared with experimental measurements of direct irradiance at normal incidence obtained using an Optronic OL 754 in the 300-400 nm range. The relative RMSD and MBD parameters have been used to estimate the deviations of the modelled values with respect to the experimental values. The results indicate that the deviations are smaller when the SMARTS2 model is used with the appropriate aerosol coefficients.

RadiationRadiological and Ultrasound Technologymedicine.diagnostic_testbiologybusiness.industryRadiació ultravioladaRadiation dosePublic Health Environmental and Occupational HealthIrradianceGeneral Medicinebiology.organism_classificationmedicine.disease_causeAtmospheric sciencesAerosolOpticsSpectrophotometrymedicineUltraviolet irradiationRange (statistics)Environmental scienceRadiology Nuclear Medicine and imagingbusinessValenciaUltravioletRadiation Protection Dosimetry
researchProduct

Mechanisms of interference of p-diphenols with the Trinder reaction

2020

p-Diphenols, such as homogentisic acid, gentisic acid, etamsylate, and calcium dobesilate, interfere with diagnostic tests utilizing the Trinder reaction but the mechanisms of these effects are not fully understood. We observed substantial differences both in oxidation of p-diphenols by horseradish peroxidase and their influence on oxidation of 4-aminoantipyrine and various phenolic substrates. Homogentisic acid was rapidly oxidized by the enzyme and completely blocked chromophore formation. Enzymatic oxidation of the remaining p-diphenols was slow and they only moderately inhibited chromophore formation. However, in the presence of standard substrates all tested p-diphenols were rapidly co…

RadicalSubstituentElectronsPhotochemistry01 natural sciencesBiochemistryRedoxHorseradish peroxidaseHomogentisic acidchemistry.chemical_compoundGentisic acidPhenolsDrug DiscoveryBenzoquinonesHomogentisic acidGentisic acidEnzymatic assay interferenceHydrogen peroxideMolecular BiologyHorseradish PeroxidaseCalcium dobesilatebiology010405 organic chemistryOrganic ChemistryHydrogen PeroxideChromophoreEtamsylate0104 chemical sciencesAmpyrone010404 medicinal & biomolecular chemistrychemistrySpectrophotometrybiology.proteinOxidation-ReductionTrinder reactionBioorganic Chemistry
researchProduct

Efficient flow injection and sequential injection methods for spectrophotometric determination of oxybenzone in sunscreens based on reaction with Ni(…

2001

Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LO…

Reaction conditionsChromatographymedicine.diagnostic_testColor reactionAnalytical chemistryBiochemistryHigh-performance liquid chromatographySensitivity and Specificitychemistry.chemical_compoundSequential injectionBenzophenoneschemistryAmmoniaNickelSpectrophotometrySpectrophotometrymedicineIndicators and ReagentsOxybenzoneQuantitative analysis (chemistry)Sunscreening AgentsStoichiometryChromatography High Pressure LiquidFresenius' journal of analytical chemistry
researchProduct

Use of triacylglycerol profiles established by high performance liquid chromatography with ultraviolet–visible detection to predict the botanical ori…

2011

A method for the determination of triacylglycerols (TAGs) in vegetable oils from different botanical origins by HPLC with UV–vis detection has been developed. Using a core-shell particle packed column (C18, 2.6 micron), TAG separation was optimized in terms of mobile phase composition and column temperature. Using isocratic elution with acetonitrile/n-pentanol at 10 °C, excellent efficiency with good resolution between most of the TAG peak pairs, within a total analysis time of 15 min, was achieved. Using mass spectrometry detection, a total of 15 peaks, which were common to oils of six different botanical origins (corn, extra virgin olive, grapeseed, hazelnut, peanut and soybean) were iden…

Resolution (mass spectrometry)Analytical chemistrymedicine.disease_causeMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySpectrophotometrymedicinePlant OilsChromatography High Pressure LiquidTriglyceridesPacked bedBOTANICAL ORIGINIsocratic elutionChromatographymedicine.diagnostic_testChemistryOrganic ChemistryDiscriminant Analysisfood and beveragesGeneral MedicineTRIACYLGLYCEROLSLINEAR DISCRIMINANT ANALYSISPhase compositionSpectrophotometry UltravioletHPLCVEGETABLE OILSUltravioletJournal of Chromatography A
researchProduct

High-performance liquid chromatographic separation of modified and native melittin following transglutaminase-mediated derivatization with a dansyl f…

1991

Abstract The 26-amino acid linear, amphiphilic peptide melittin was enzymatically modified with the fluorescent probe monodansylcadaverine using guinea pig liver transglutaminase and a fluorescent derivative of stoichiometry 1:1 was obtained. Reversed-phase and size-exclusion high-performance liquid chromatographic modes were tested in order to resolve the labelled peptide and native species. The influence of several operational variables was analysed and the elution conditions were optimized so that a satisfactory resolution could be achieved in both instances in a rapid, easy manner. Both chromatographic modes offer the possibility of accurate monitoring of the time course of the enzyme-m…

Resolution (mass spectrometry)Tissue transglutaminaseGuinea PigsMolecular Sequence DataPeptideBiochemistryMelittinAnalytical Chemistrychemistry.chemical_compoundCadaverineAmphiphileAnimalsAmino Acid SequenceDerivatizationChromatography High Pressure Liquidchemistry.chemical_classificationDansyl CompoundsChromatographyTransglutaminasesbiologyChemistryElutionOrganic ChemistryGeneral MedicineFluorescenceMelittenSpectrometry Fluorescencebiology.proteinChromatography GelSpectrophotometry UltravioletJournal of chromatography
researchProduct

Determination of liposoluble vitamins in cooked meals, milk and milk products by liquid chromatography

2002

A method for the simultaneous determination of liposoluble vitamins in cooked meals was established. Saponification was performed with 50% (w/v) KOH at 80 degrees C, and ascorbic acid was added as antioxidant. The subsequent extraction was carried out with diethyl ether. This was followed by a liquid chromatographic separation on a reversed-phase C18 column with methanol-water (94:6, v/v as the mobile phase. Retinyl acetate was used as the internal standard. The analytical parameters linearity, detection limit (0.19 and 8.33 microg/100 g for retinol and alpha-tocopherol, respectively), precision of the method (RSD=5.24 and 6.99% for retinol and alpha-tocopherol, respectively) and recovery a…

Retinyl acetateSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundAnimalsDetection limitChromatographyOrganic ChemistryExtraction (chemistry)RetinolReproducibility of Resultsfood and beveragesVitaminsGeneral MedicineAscorbic acidLipidsMilkSolubilitychemistrySpectrophotometry UltravioletDairy ProductsDiethyl etherSaponificationChromatography LiquidJournal of Chromatography A
researchProduct

Photoinduced Electron Transfer in Multiporphyrinic Interlocked Structures: The Effect of Copper(I) Coordination in the Central Site

2004

Photoinduced processes have been determined in a [2]catenane containing a zinc(II) porphyrin, a gold(III) porphyrin, and two free phenanthroline binding sites, Zn-Au(+), and in the corresponding copper(I) phenanthroline complex, Zn-Cu(+)-Au(+). In acetonitrile solution Zn-Au(+) is present in two different conformations: an extended one, L, which accounts for 40 % of the total, and a compact one, S. In the L conformation, the electron transfer from the excited state of the Zn porphyrin to the gold-porphyrin unit (k = 1.3x10(9) s(-1)) is followed by a slow recombination (k = 8.3x10(7) s(-1)) to the ground state. The processes in the S conformation cannot be clearly resolved but a charge-separ…

RotaxanesMetalloporphyrinsPhotochemistryPhenanthrolineCatenaneMolecular Conformationchemistry.chemical_elementElectronsPhotochemistryCatalysisPhotoinduced electron transferElectron Transportchemistry.chemical_compoundElectron transferChemistryOrganic ChemistryGeneral ChemistryPorphyrinCopperZincCrystallographyEnergy TransferSpectrophotometryExcited stateGoldGround stateCopperChemistry - A European Journal
researchProduct

Infrared based saliva screening test for COVID‐19

2021

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in an unprecedented need for diagnostic testing that is critical in controlling the spread of COVID-19. We propose a portable infrared spectrometer with purpose-built transflection accessory for rapid point-of-care detection of COVID-19 markers in saliva. Initially, purified virion particles were characterized with Raman spectroscopy, synchrotron infrared (IR) and AFM-IR. A data set comprising 171 transflection infrared spectra from 29 subjects testing positive for SARS-CoV-2 by RT-qPCR and 28 testing negative, was modeled using Monte Carlo Double Cross Validation with 50 randomized test and model sets. The testing se…

SalivaMaterials scienceCoronavirus disease 2019 (COVID-19)Spectrophotometry InfraredInfraredPoint-of-care testingInfrared spectroscopy010402 general chemistry01 natural sciencesProof of Concept StudySensitivity and SpecificityCatalysisSpecimen HandlingCohort Studies03 medical and health sciences0302 clinical medicineCOVID-19 TestingSpectrophotometryChlorocebus aethiopsmedicineCOVID-19 diagnostic infrared spectroscopy Raman spectroscopy saliva SARS-CoV-2 virionsAnimalsHumansQDLeast-Squares AnalysisSalivaVero CellsMass screening030304 developmental biologyDetection limit0303 health sciencessalivaChromatographymedicine.diagnostic_test010405 organic chemistrySARS-CoV-2COVID-19Discriminant AnalysisGeneral Chemistry030206 dentistryGeneral Medicine0104 chemical sciences3. Good healthPoint-of-Care TestingMonte Carlo MethodATR-FTIRResearch ArticleAngewandte Chemie (International Ed. in English)
researchProduct

Characterisation of two new radiochromic gel dosimeters TruView™ and ClearView™ in combination with the vista™ optical CT scanner: A feasibility study

2018

This study aims at characterising the properties of TruView™ and ClearView™ two new gel dosimeters (Modus Medical Devices Inc.) and at studying the feasibility of relative dosimetry using these dosimeters and the Vista™ Optical CT scanner to accurately evaluate dose.In this work, we investigated key dosimetric aspects (dose response, energy and dose rate dependence) and stability of these radiochromic gels initiated in preliminary works (Huet et al., 2017; Colnot et al., 2017) using spectrophotometric measurements. Moreover, by mean of optical CT scanning (Vista™), their performances to measure relative depth dose (PDD) and cross profiles were analysed.TruView™ and ClearView™ present a line…

ScannerTomography Scanners X-Ray ComputedMaterials scienceBiophysicsGeneral Physics and AstronomyElectrons[SDV.CAN]Life Sciences [q-bio]/Cancer[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptical ctRelative depthDosimetryRadiology Nuclear Medicine and imagingPhoton beamRadiometryComputingMilieux_MISCELLANEOUSPhotonsDosimeterPhantoms ImagingRadiation DosimetersStray lightOptical ImagingUncertaintyGeneral MedicineSpectrophotometry030220 oncology & carcinogenesisCalibrationFeasibility StudiesTomography X-Ray ComputedDose rateBiomedical engineering
researchProduct

Copper(II) complexes with 1,5-bis(2-hydroxybenzaldehyde)carbohydrazone

2014

Abstract The acid–base properties of 1,5-bis(2-hydroxybenzaldehyde)carbohydrazone (H4L) and its thioanalogue 1,5-bis(2-hydroxybenzaldehyde)thiocarbohydrazone (H4LS) have been studied experimentally by pH-potentiometry and UV–Vis spectrophotometry and theoretically by using DFT methods. Copper(II) complexes [Cu2(HL)(DMSO)2(H2O)]NO3·H2O (1), [{Cu2(HL)(DMF)(H2O)}n][{Cu2(HL)(DMF)NO3}n](NO3)n (2), [Cu2(HL)(DMF)2(H2O)]HSO4·H2O (3), [Cu2(HL)(DMF)2(H2O)][Cu2(HL)(SO4)(H2O)(DMF)2]·2H2O (4) and [Cu4(HL)2(HSO4)(DMF)2]HSO4 (5), where H4L = 1,5-bis(2-hydroxybenzaldehyde)carbohydrazone, have been synthesised. Complexes 1–3 have been characterised by elemental analysis, IR spectroscopy, ESI mass spectromet…

Schiff basemedicine.diagnostic_testLigandStereochemistryInfrared spectroscopychemistry.chemical_elementMagnetic susceptibilityCopperInorganic Chemistrychemistry.chemical_compoundCrystallographyDeprotonationchemistrySpectrophotometryMaterials ChemistrymedicinePhysical and Theoretical ChemistryCyclic voltammetryPolyhedron
researchProduct