Search results for "Pillar"

showing 10 items of 877 documents

Analytical methods to determine cocaine contamination of banknotes from around the world

2008

Abstract The presence of cocaine in a significant number of UK pounds (Xxxx), Euros (€) and North American banknotes ($) in general circulation requires appropriate tools to do determinations. This article discusses the-state-of-the-art in the analysis of cocaine on banknotes. We summarize the usual extraction methods of currency samples and compare them, especially with respect to avoiding sample damage. We critically discuss analytical methods, namely gas chromatography (GC) and liquid chromatography (LC), capillary electrophoresis (CE), immunoassay, thermal desorption tandem mass spectrometry (TD-MS2) and ion-mobility spectrometry (IMS). We also review cocaine levels on banknotes around …

BanknoteChromatographyCapillary electrophoresisChemistryGeneral Circulation ModelExtraction methodsSample preparationGas chromatographyContaminationMass spectrometrySpectroscopyAnalytical ChemistryTrAC Trends in Analytical Chemistry
researchProduct

Crystal Structure and Host-Guest Binding Ability of Three Types of Pillar[5]arenes

2015

A systematic research of the structural characterization and the host-guest binding abilities between three types of pillar[5]arenes 3–5 (3 for Structure Type I, 4 for Structure Type II and 5 for Structure Type III) is carried out by 1H NMR measurements and X-ray study. The results show that the configurations or symmetry of their cavities not only have large difference in these three types of pillar[5]arenes, but also have more or less variations even in the same structure type or the same host locked different guests such as crystals of 3a–3b, 4a–4d. On the other hand, the complexation behavior of pillar[5]arenes with 1,4-dibromobutane (DBB) is affected by the different symmetrical struct…

Binding abilityCrystallographyChemistryProton NMRPillarGeneral ChemistryCrystal structureStructure typeChinese Journal of Chemistry
researchProduct

Reactivity of anticancer metallodrugs with serum proteins: New insights from size exclusion chromatography-ICP-MS and ESI-MS

2010

International audience; A method based on the coupling of high resolution size-exclusion liquid chromatography using a polymer stationary phase with inductively coupled plasma mass spectrometry was developed to study the interactions of two metallodrugs - cisplatin and RAPTA-T - with the serum proteins albumin and transferrin. In contrast to previous approaches, the technique allowed the total recovery of the metals from the column and was able to discriminate between the different species of the metallodrugs and their complexes with the proteins at femtomolar detection levels. Metal binding was found to be dependent on the protein concentration and on the incubation time of the sample. Cis…

Binding-SitesElectrospray ionizationSize-exclusion chromatographyPeptidePlasma-Mass Spectrometry010402 general chemistry01 natural sciencesArticleAnalytical ChemistryOrganometallic Ruthenium CompoundCapillary electrophoresisComplexes[CHIM.ANAL]Chemical Sciences/Analytical chemistry[CHIM]Chemical SciencesInductively coupled plasma mass spectrometrySpectroscopychemistry.chemical_classificationChromatographyChemistry010401 analytical chemistryCisplatin BindingTransferrinAlbuminCapillary-ElectrophoresisMultidimensional Liquid-ChromatographyBlood proteins0104 chemical sciencesTransferrinPlatinum Antitumor ChemistryEscherichia-Coli
researchProduct

Finite Size Effects in Thin Film Simulations

2003

Phase transitions in thin films are discussed, with an emphasis on Ising-type systems (liquid-gas transition in slit-like pores, unmixing transition in thin films, orderdisorder transitions on thin magnetic films, etc.) The typical simulation geometry then is a L xL x D system, where at the low confining L x L surfaces appropriate boundary “fields” are applied, while in the lateral directions periodic boundary conditions are used. In the z-direction normal to the film, the order parameter always is inhomogeneous, due to the boundary “fields” at the confining surfaces. When one varies the temperature T from the region of the bulk disordered phase to a temperature below the critical temperatu…

BinodalPhase transitionMaterials scienceCapillary condensationCondensed matter physicsPhase (matter)Periodic boundary conditionsBoundary (topology)Symmetry breakingThin film
researchProduct

Molecular Dynamics simulation of evaporation processes of fluid bridges confined in slit-like pore

2009

A simple fluid, described by point-like particles interacting via the Lennard-Jones potential, is considered under confinement in a slit geometry between two walls at distance Lz apart for densities inside the vapor-liquid coexistence curve. Equilibrium then requires the coexistence of a liquid "bridge" between the two walls, and vapor in the remaining pore volume. We study this equilibrium for several choices of the wall-fluid interaction (corresponding to the full range from complete wetting to complete drying, for a macroscopically thick film), and consider also the kinetics of state changes in such a system. In particular, we study how this equilibrium is established by diffusion proces…

BinodalRange (particle radiation)Materials scienceCapillary actionEvaporationThermodynamicsFOS: Physical sciencesCondensed Matter - Soft Condensed MatterPhysics::Fluid DynamicsMolecular dynamicsVolume (thermodynamics)Soft Condensed Matter (cond-mat.soft)WettingDiffusion (business)
researchProduct

Combination of supported liquid membrane and solid-phase extraction for sample pretreatment of triazine herbicides in juice prior to capillary electr…

2002

A possibility of a combination of supported liquid membrane (SLM) and solid-phase extraction (SPE) for the determination of atrazine at microgram level in different type of fruit juices is presented. In comparison to SPE extraction from juice samples, the application of SLM-SPE enrichment provides much cleaner extracts and the possibility of lowering the limit of detection as low as 30 microg/l. However, it was also shown that by appropriate manipulation of SLM extraction conditions mainly flow-rate of donor phase and volume ratio between donor and acceptor phase, the level of detection can be further decreased to 10 microg/l. The results suggest that the application of SLM extraction prior…

Biochemistryfruit juiceAnalytical ChemistryBeveragessupporter liquid membrane extractionchemistry.chemical_compoundCapillary electrophoresistriazinesSample preparationsolid-phase extractionSolid phase extractionAtrazineTriazineDetection limitChromatographyChemistryHerbicidesOrganic ChemistryElectrophoresis CapillaryMembranes ArtificialGeneral MedicinepesticidesMembraneCalibrationQuantitative analysis (chemistry)atrazineJournal of Chromatography A
researchProduct

Determination of biogenic amines in meat by combined ion-exchange capillary gas chromatography

1984

Abstract A procedure is described for the determination of putrescine, cadaverine and histamine in meat. Crude perchloric acid extracts were pre-separated on a weakly acidic cation exchanger and the amines quantified by capillary gas chromatography. The diamines were analysed as trifluoroacetyl derivatives and histamine was converted into N α -trifluoroacetyl-N τ -ethoxycarbonylhistamine. The accuracy of the determination of diamines was examined by a precipitation pre-separation method and by mass fragmentometric quantification. The proposed procedure allows the sensitive, sufficiently precise and highly specific determination of putrescine and cadaverine in meat.

Biogenic AminesChromatography GasMeatSwineTetraphenylborateBiochemistryGas Chromatography-Mass SpectrometryAnalytical Chemistrychemistry.chemical_compoundCadaverinePutrescineAnimalsChemical PrecipitationTrifluoroacetic AcidPerchloric acidCadaverineChromatographyIon exchangePrecipitation (chemistry)Organic ChemistryGeneral MedicineChromatography Ion ExchangeCapillary gas chromatographychemistryPutrescineHistamineHistamineJournal of Chromatography A
researchProduct

Identifying human platelet glycoproteins IIb and IIIa by capillary electrophoresis.

1998

Glanzmann thrombasthenia (GT) is an inherited hemorrhagic defect due to a failure of the platelet membrane glycoprotein (GP) IIb–IIIa complex. Capillary electrophoresis (CE) analysis of solubilized platelet membranes from normal individuals showed the presence of two peaks with a migration time of 27 and 29 min, respectively. An excellent run-to-run and day-to-day reproducibility of the technique (< 1% variation of the retention time) was documented. Using an automated Ferguson method, the apparent molecular masses were 100.0 kDa and 138.5 kDa, respectively. Immunoprecipitation with monoclonal antibodies anti-GP IIIa (B59.2.1) and anti-IIb (61.9.1.3) showed the two peaks as IIIa and IIb, re…

Blood PlateletsMaleClinical BiochemistryPlatelet Glycoprotein GPIIb-IIIa ComplexPlatelet membrane glycoproteinBiochemistryAnalytical ChemistryCapillary electrophoresisThrombastheniamedicineHumansPlateletChildPolyacrylamide gel electrophoresischemistry.chemical_classificationMembrane GlycoproteinsGlanzmann's thrombastheniaCell MembraneElectrophoresis Capillarymedicine.diseaseFlow CytometryMolecular biologyPrecipitin TestsPlatelet Glycoprotein GPIIb-IIIa ComplexchemistryGlycoproteinThrombastheniaElectrophoresis
researchProduct

Identification and quantitation of trace amounts of barbiturates with glass capillary gas chromatography

1979

Pre-chromatographic reactions are no longer a necessary evil. Equipment such as the microrefluxer now allows reproducible 7-μl-reactions to be carried out in a short time. Thus multiple derivatisations can be used together with glass capillary GC for routine identifications. The method has been succesfully applied to barbiturates. Retention data of their methyl-, allyl- and benzyl-derivatives are given. Quantitative blood level determinations are briefly discussed.

Blood levelChromatographyTrace AmountsChemistryCapillary actionGeneral Chemical EngineeringGas chromatographyCapillary gas chromatographyJournal of High Resolution Chromatography
researchProduct

BRAFV660E mutation and Timp-1 hyper-expression in classical variants of papyllary thyroid carcinoma.

2009

BrafV600E Papillary thyroid carcinoma TIMP-1Settore MED/13 - Endocrinologia
researchProduct