Search results for "Plethysmograph"
showing 10 items of 94 documents
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Investigation into isoprenaline resistance in patients with obstructive lung disease
1974
12 patients with chronic obstructive lung disease have been studied in an investigation regarding the causes of resistance to isoprenaline. The effects of repeated intravenous doses of 10 µg isoprenaline were assessed by cross over comparison before and after infusions of isoprenaline and a placebo; the infusions lasted for 35 to 40 min and the amount of isoprenaline infused was 0.5 µg/min. Total resistance, thoracic gas volume (whole-body plethysmography) and heart rate (ECG) were measured. No decrease in bronchospasmolytic or positive chronotopic effects on single isoprenaline injections could be demonstrated after prolonged infusions of isoprenaline.
Tolerance to nitroglycerin-induced preconditioning of the endothelium: a human in vivo study
2009
Damage and dysfunction of the vascular endothelium critically influence clinical outcomes after ischemia and reperfusion (I/R). Brief exposure to organic nitrates can protect the vascular endothelium from I/R injury via a mechanism that is similar to ischemic preconditioning and is independent of hemodynamic changes. The clinical relevance of these protective effects clearly depends on whether they can be sustained over time. Twenty-four healthy (age 25–32) male volunteers were randomized to receive 1) transdermal nitroglycerin (GTN; 0.6 mg/h) administered for 2 h on 1 day only, 2) transdermal GTN for 2 h/day for 7 days, or 3) continuous therapy with transdermal GTN for 7 days. Eight volunt…
Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness
2013
Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…
Cerebrovascular and cardiovascular variability interactions investigated through conditional joint transfer entropy in subjects prone to postural syn…
2017
Objective: A model-based conditional transfer entropy approach was exploited to quantify the information transfer in cerebrovascular (CBV) and cardiovascular (CV) systems in subjects prone to develop postural syncope. Approach: Spontaneous beat-to-beat variations of mean cerebral blood flow velocity (MCBFV) derived from a transcranial Doppler device, heart period (HP) derived from surface electrocardiogram, mean arterial pressure (MAP) and systolic arterial pressure (SAP) derived from finger plethysmographic arterial pressure device were monitored at rest in supine position (REST) and during 60° head-up tilt (TILT) in 13 individuals (age mean ± standard deviation: 28 ± 9 years, min-max r…
The Effects of Prostaglandin E-1 in Patients with Intermittent Claudication
2006
Aim of the study is to evaluate the effects of Prostaglandin E-1 (PGE-1) in patients with peripheral arterial disease (PAD) at the 2nd b stage Fontaines classification. The study, controlled, single blinded, enrolled 123 patients with intermittent claudication that were randomised in two groups; the first group received a treatment with PGE-1 while the second one received a pentoxifylline-buflomedil association by venous infusion. We evaluated: Pain Free Walking Distance (PFWD), Maximum Walking Distance (MWD), Rest Flow (RF), Peak Flow (PF), Basal (BVR) and Minimal Vascular Resistance (MVR) with a strain gauge plethysmograph, Resting Flow (RF), Peak Flow (PF), time to reach the Peak Flow (t…
Information domain analysis of respiratory sinus arrhythmia mechanisms.
2019
Ventilation related heart rate oscillations – respiratory sinus arrhythmia (RSA) – originate in human from several mechanisms. Two most important of them – the central mechanism (direct communication between respiratory and cardiomotor centers), and the peripheral mechanism (ventilation-associated blood pressure changes transferred to heart rate via baroreflex) have been described in previous studies. The major aim of this study was to compare the importance of these mechanisms in the generation of RSA non-invasively during various states by quantifying the strength of the directed interactions between heart rate, systolic blood pressure and respiratory volume signals. Seventy-eight healthy…
Calf muscle pump impairment and delayed healing of venous leg ulcers: Air plethysmographic findings
2007
There is a need for a diagnostic tool to predict clinical outcome of venous leg ulcer patients, as the prognosis of healing based on clinical data alone has not appeared to be satisfactory. Air plethysmographic assessment of calf muscle pump was performed in the supine and upright position in 129 patients with active ulcers on their legs. All patients were managed in a specialized leg ulcer clinic. Results of air plethysmography were compared to clinical data and time of healing of ulcers. Muscle pump failure was found in 42.6% of extremities (supine position, 33.3%; upright, 22.5%; both, 12.4%). Patients with insufficient pump were older, and their ulcers were larger. Failure of pump was f…
Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure
2011
We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…
Hypertension and peripheral arterial hemodynamics.
1995
Sixty uncomplicated hypertensive patients (30 stable and 30 borderline) were studied, by strain gauge plethysmography, in comparison with 25 normotensive subjects, in order to evaluate the arterial hemodynamics of the lower limbs in essential hypertension and to verify the different pattern in borderline and in stable hypertensives. Resting blood flow, even if slightly decreased in hypertensive groups, did not show significant differences in its mean values; peak flow, instead, was reduced proportionally to the severity of hypertension in all the hypertensive patients, but only in the stable hypertensives was it statistically significant. Minimal vascular resistance showed a similar behavi…