Search results for "Plethysmograph"

showing 10 items of 94 documents

Effect of time-of-day-specific strength training on muscular hypertrophy in men.

2009

The purpose of the present study was to examine effects of time-of-day-specific strength training on muscle hypertrophy and maximal strength in men. A training group underwent a 10-week preparatory training (wk 0-wk 10) scheduled between 17:00 and 19:00 hours. Thereafter, the subjects were randomized either to a morning or afternoon training group. They continued with a 10-week time-of-day-specific training (wk 11-wk 20) with training times between 07:00 and 09:00 hours and 17:00 and 19:00 hours in the morning group and afternoon groups, respectively. A control group did not train but was tested at all occasions. Quadriceps femoris (QF) cross-sectional areas (CSA) and volume were obtained b…

AdultMalemedicine.medical_specialtyTime FactorsStrength trainingPhysical Therapy Sports Therapy and RehabilitationIsometric exerciseMuscle hypertrophyIsometric ContractionMedicinePlethysmographHumansOrthopedics and Sports MedicineKneeCircadian rhythmMuscle StrengthMuscle SkeletalMorningAnalysis of Variancebusiness.industryTraining (meteorology)Resistance TrainingGeneral MedicineHypertrophyAdaptation PhysiologicalMagnetic Resonance ImagingCircadian RhythmPlethysmographyTorqueAnesthesiaPhysical therapyLinear ModelsAnalysis of variancebusinessJournal of strength and conditioning research
researchProduct

Regression of structural vascular changes in hypertensives after captopril treatment.

1992

In order to investigate whether hypertension-related structural vascular changes may be influenced by antihypertensive treatment, 10 patients were studied suffering from essential arterial hypertension, five males and five females, aged between 34 and 61 years (mean age: 46.9 +/- 8.13 years). All patients received a placebo for 1 week and then captopril, 75 mg b.i.d. for 3 months. After placebo and captopril treatments, the following parameters were evaluated: SBP, DBP, mean blood pressure (MBP), by the formula 1/3 (SBP + 2 x DBP) and basal and minimal vascular resistances, respectively obtained by the ratios MBP/rest flow and MBP/peak flow. Blood flows have been obtained by strain gauge pl…

AdultMean arterial pressuremedicine.medical_specialtyCaptoprilHemodynamicsBlood PressureMuscle Smooth VascularInternal medicinemedicineHumansSystoleLegbusiness.industryHemodynamicsCaptoprilMiddle AgedPlethysmographyBlood pressureMean blood pressuremedicine.anatomical_structureEndocrinologyHypertensionVascular resistanceFemaleVascular ResistanceCardiology and Cardiovascular MedicinebusinessBlood Flow VelocityBlood vesselmedicine.drugEuropean heart journal
researchProduct

Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths

2016

The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…

AdultPathologymedicine.medical_specialtyAdolescentBiomedical EngineeringLinimentHyperemiaCutaneous microcirculation02 engineering and technologyAdministration Cutaneous01 natural sciencesMicrocirculation010309 opticsBiomaterialsYoung AdultPhotoplethysmogram0103 physical sciencesImage Processing Computer-AssistedHumansMedicinePhotoplethysmographySkinbusiness.industryMicrocirculationEquipment DesignLaser Doppler velocimetryHand021001 nanoscience & nanotechnologyArterial occlusionAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials0210 nano-technologybusinessPerfusionPreclinical imagingAnesthesia LocalBiomedical engineeringJournal of Biomedical Optics
researchProduct

Bilateral photoplethysmography studies of the leg arterial stenosis.

2005

A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if compared with those of the healthy leg, were much weaker, with delayed arrival as a consequence of increased pulse wave transit time (PWTT) due to higher vascular resistance. The specific PWTT delays for the occluded legs were in the range of 20-80 ms, while in the case of healthy subjects the leg PPG…

Adultmedicine.medical_specialtyPhysiologyBiomedical EngineeringBiophysicsArterial Occlusive DiseasesBlood PressurePhysiology (medical)PhotoplethysmogramInternal medicineHealthy controlmedicineOscillometryHumansPhotoplethysmographyAgedAged 80 and overPeripheral Vascular DiseasesLegArterial stenosisbusiness.industryHealthy subjectsMiddle Agedmedicine.diseaseSurgerybody regionsStenosisBlood pressuremedicine.anatomical_structureVascular resistanceCardiologybusinessPhysiological measurement
researchProduct

Sympathetic Vasomotor Response of the Radial Artery in Patients With Diabetic Foot Syndrome

2003

OBJECTIVE—Neurophysiological assessment of the peripheral autonomic system is characterized by various limitations. An alternative approach to laser Doppler and venous plethymography is the assessment of the sympathetic vasomotor response of the radial artery obtained by continuous wave Doppler sonography. Nomogram data have been established and demonstrate the temporary disappearance of diastolic flow after coughing or deep inspiration. RESEARCH DESIGN AND METHODS—We assessed the sympathetic vasomotor response in 25 patients (mean age 64 years, range 43–76) with diabetic foot syndrome. The Doppler data were correlated with nerve conduction studies of the median and peroneal nerve, the exte…

Adultmedicine.medical_specialtySympathetic nervous systemSympathetic Nervous SystemSystoleEndocrinology Diabetes and MetabolismNeural ConductionDiastoleNerve conduction velocityDiastoleReference ValuesInternal medicinemedicine.arteryReaction TimeInternal MedicinemedicineHumansPlethysmographUltrasonography Doppler ColorSystoleRadial arteryAgedAdvanced and Specialized Nursingbusiness.industryMiddle AgedLaser Doppler velocimetrymedicine.diseaseDiabetic footDiabetic FootSurgerymedicine.anatomical_structureCoughRadial ArteryCardiologybusinessBlood Flow VelocityDiabetes Care
researchProduct

Association between cardiorespiratory fitness and metabolic health in overweight and obese adults

2021

Background Cardiorespiratory fitness (CRF) has been inversely associated with insulin resistance and clustering of cardiometabolic risk factors among overweight and obese individuals. However, most previous studies have scaled CRF by body mass (BM) possibly inflating the association between CRF and cardiometabolic health. We investigated the associations of peak oxygen uptake (V O2peak) and peak power output (Wpeak) scaled either by BM-1, fat free mass (FFM-1), or by allometric methods with individual cardiometabolic risk factors and clustering of cardiometabolic risk factors in 55 overweight or obese adults with metabolic syndrome. Methods V O2peak and Wpeak were assessed by a maximal cycl…

Adultmedicine.medical_specialtymedicine.medical_treatmentPhysical Therapy Sports Therapy and RehabilitationOverweightBody Mass Indexchemistry.chemical_compoundInsulin resistanceRisk FactorsInternal medicinemedicineHumansInsulinPlethysmographOrthopedics and Sports MedicineObesityTriglyceridesMetabolic SyndromeGlycated Hemoglobinbusiness.industryCholesterolInsulinCholesterol HDLVO2 maxCardiorespiratory fitnessOverweightmedicine.diseaseOxygenGlucoseEndocrinologyCardiorespiratory FitnesschemistryCardiovascular Diseasesmedicine.symptomMetabolic syndromebusinessThe Journal of Sports Medicine and Physical Fitness
researchProduct

Photoplethysmography system for blood pulsation detection in unloaded artery conditions

2012

Photoplethysmography (PPG) is an optical method of blood pulsation recording and has been extensively studied for decades. Recently PPG is widely used in the medical equipment for patient monitoring and in laboratories for research and physiological studies. In spite of the technological progress in the field of medical equipment, there are no generally accepted standards for clinical PPG measurements up to date. One of the most important factors affecting PPG waveform is the contact pressure between tissue and PPG probe. The aim of the current study was to develop and evaluate a system for software-assisted PPG signal acquisition from the unloaded artery. Novel PPG waveform derived Optimal…

Blood pressureTransmural pressuremedicine.anatomical_structureComputer scienceRemote patient monitoringPhotoplethysmogrammedicinePlethysmographWaveformsense organsArteryBiomedical engineeringSPIE Proceedings
researchProduct

Influence of the scalp thickness on the intracranial contribution to rheoencephalography

2004

In spite of the great efforts made by the scientific community, up to now there is no agreement about the rheoencephalography (REG) capability to reflect cerebral blood flow (CBF). Moreover, a standard procedure and the optimal electrode arrangement have not been established yet. In a previous study, we found, using a classical four-shell spherical model of the head and solving it by numerical methods that, theoretically, there could exist an electrode arrangement to register an REG II free of extracranial contribution. In this paper, we have studied the influence of scalp thickness on the intracranial contribution to REG II. The study has been performed by solving the head model, using in …

Brain MappingScalpRadiological and Ultrasound TechnologyModels NeurologicalMathematical analysisModels CardiovascularBrainElectroencephalographyStandard procedureRheoencephalographymedicine.anatomical_structureCerebral blood flowCerebrovascular CirculationScalpHead modelmedicineHumansComputer SimulationRadiology Nuclear Medicine and imagingDiagnosis Computer-AssistedPlethysmography ImpedanceAlgorithmMathematicsPhysics in Medicine and Biology
researchProduct

Pulse rate variability measurement with camera-based photoplethysmography

2021

Electrocardiogram (ECG) has been used by doctors and biomedical researchers to measure cardiac parameters such as Heart Rate (HR) and Heart Rate Variability (HRV). HR is a medical index for health monitoring and the HRV is a sign to reflect the activities of Autonomic Nervous System (ANS) and can be used for emotion recognition applications. Recently, remote photoplethysmography (rPPG) has evolved as a non-contact technique for measuring vital cardiac signs. Compared with ECG, this technique is non-invasive, low-cost, comfortable and possibly utilized in long-term monitoring. It has great potential in remote health assessment and emotion detection. However, the rPPG is a video-based method,…

Cardiac varaibilioty[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV]Photoplethysmographie (PPG)Video content analysis[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]Variabilité cardiaquePhotoplethysmography (PPG)Analyse de contenu vidéo
researchProduct

A preliminary investigation of the effect of contact pressure on the accuracy of heart rate monitoring by wearable PPG wrist band

2019

The increase of safety and health monitor of workers has become a crucial objective to prevent excessive physical workloads, injuries, accidents and errors. Heart rate (HR) is a very important physiological indicator which could properly describe the workers’ physical status. Recently, wearable photoplethysmographic (PPG) wristband trackers have been utilized to measure HR without hindering normal gesture of workers. However, the quality of PPG signals is highly affected by human physical motions, resulting in a poor reliable HR estimation. Specifically, during different activities and gestures, PPG sensor contact pressures may have an impact on the quality of the heart rate signal. To appr…

Computer sciencePhotoplethysmography wearable sensor PPG sensor contact pressureWearable computerSettore ING-IND/34 - Bioingegneria IndustrialeWristSignalLoad cellSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchinemedicine.anatomical_structureHeart rate monitoringHeart ratemedicineSettore ING-IND/12 - Misure Meccaniche E TermicheHeart rate variabilitysense organsContact pressureBiomedical engineering
researchProduct