Search results for "Plethysmography"

showing 10 items of 84 documents

Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths

2016

The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…

AdultPathologymedicine.medical_specialtyAdolescentBiomedical EngineeringLinimentHyperemiaCutaneous microcirculation02 engineering and technologyAdministration Cutaneous01 natural sciencesMicrocirculation010309 opticsBiomaterialsYoung AdultPhotoplethysmogram0103 physical sciencesImage Processing Computer-AssistedHumansMedicinePhotoplethysmographySkinbusiness.industryMicrocirculationEquipment DesignLaser Doppler velocimetryHand021001 nanoscience & nanotechnologyArterial occlusionAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials0210 nano-technologybusinessPerfusionPreclinical imagingAnesthesia LocalBiomedical engineeringJournal of Biomedical Optics
researchProduct

Bilateral photoplethysmography studies of the leg arterial stenosis.

2005

A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if compared with those of the healthy leg, were much weaker, with delayed arrival as a consequence of increased pulse wave transit time (PWTT) due to higher vascular resistance. The specific PWTT delays for the occluded legs were in the range of 20-80 ms, while in the case of healthy subjects the leg PPG…

Adultmedicine.medical_specialtyPhysiologyBiomedical EngineeringBiophysicsArterial Occlusive DiseasesBlood PressurePhysiology (medical)PhotoplethysmogramInternal medicineHealthy controlmedicineOscillometryHumansPhotoplethysmographyAgedAged 80 and overPeripheral Vascular DiseasesLegArterial stenosisbusiness.industryHealthy subjectsMiddle Agedmedicine.diseaseSurgerybody regionsStenosisBlood pressuremedicine.anatomical_structureVascular resistanceCardiologybusinessPhysiological measurement
researchProduct

Influence of the scalp thickness on the intracranial contribution to rheoencephalography

2004

In spite of the great efforts made by the scientific community, up to now there is no agreement about the rheoencephalography (REG) capability to reflect cerebral blood flow (CBF). Moreover, a standard procedure and the optimal electrode arrangement have not been established yet. In a previous study, we found, using a classical four-shell spherical model of the head and solving it by numerical methods that, theoretically, there could exist an electrode arrangement to register an REG II free of extracranial contribution. In this paper, we have studied the influence of scalp thickness on the intracranial contribution to REG II. The study has been performed by solving the head model, using in …

Brain MappingScalpRadiological and Ultrasound TechnologyModels NeurologicalMathematical analysisModels CardiovascularBrainElectroencephalographyStandard procedureRheoencephalographymedicine.anatomical_structureCerebral blood flowCerebrovascular CirculationScalpHead modelmedicineHumansComputer SimulationRadiology Nuclear Medicine and imagingDiagnosis Computer-AssistedPlethysmography ImpedanceAlgorithmMathematicsPhysics in Medicine and Biology
researchProduct

Pulse rate variability measurement with camera-based photoplethysmography

2021

Electrocardiogram (ECG) has been used by doctors and biomedical researchers to measure cardiac parameters such as Heart Rate (HR) and Heart Rate Variability (HRV). HR is a medical index for health monitoring and the HRV is a sign to reflect the activities of Autonomic Nervous System (ANS) and can be used for emotion recognition applications. Recently, remote photoplethysmography (rPPG) has evolved as a non-contact technique for measuring vital cardiac signs. Compared with ECG, this technique is non-invasive, low-cost, comfortable and possibly utilized in long-term monitoring. It has great potential in remote health assessment and emotion detection. However, the rPPG is a video-based method,…

Cardiac varaibilioty[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV]Photoplethysmographie (PPG)Video content analysis[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]Variabilité cardiaquePhotoplethysmography (PPG)Analyse de contenu vidéo
researchProduct

A preliminary investigation of the effect of contact pressure on the accuracy of heart rate monitoring by wearable PPG wrist band

2019

The increase of safety and health monitor of workers has become a crucial objective to prevent excessive physical workloads, injuries, accidents and errors. Heart rate (HR) is a very important physiological indicator which could properly describe the workers’ physical status. Recently, wearable photoplethysmographic (PPG) wristband trackers have been utilized to measure HR without hindering normal gesture of workers. However, the quality of PPG signals is highly affected by human physical motions, resulting in a poor reliable HR estimation. Specifically, during different activities and gestures, PPG sensor contact pressures may have an impact on the quality of the heart rate signal. To appr…

Computer sciencePhotoplethysmography wearable sensor PPG sensor contact pressureWearable computerSettore ING-IND/34 - Bioingegneria IndustrialeWristSignalLoad cellSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchinemedicine.anatomical_structureHeart rate monitoringHeart ratemedicineSettore ING-IND/12 - Misure Meccaniche E TermicheHeart rate variabilitysense organsContact pressureBiomedical engineering
researchProduct

Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters

2020

The recent advances in multiparametric monitoring of biosignals and management of big data prompt for the development of devices and techniques for the extraction of indicators with physiological relevance. In this context, we have designed and realized a portable electronic system, equipped with simple biomedical sensors, able to synchronously record multiple electrocardiographic (ECG), photoplethysmographic (PPG) and breathing signals, for carrying out a non-invasive monitoring of several cardiovascular parameters. In this work, we show the results of preliminary measurements performed following a specific physiological protocol (i.e., deep breathing with 10 s per cycle). The system allow…

Computer scienceWearable electronics portable system electrocardiography (ECG) photoplethysmography (PPG) heart rate variabilitySettore ING-INF/06 - Bioingegneria Elettronica E InformaticaReal-time computingBreathingExhalationBiomedical sensorsDiaphragmatic breathingHeart rate variabilityContext (language use)Stroke volumeSettore ING-INF/01 - ElettronicaElectronic systems2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)
researchProduct

Transthoracic electrical impedance during extracorporeal hemodialysis in acute respiratory failure ("Shocked Lung syndrome").

1980

The alteration (delta Z0) of transthoracic electrical impedance (TEI) during extracorporeal hemodialysis (EHD) was investigated in two Groups of patients with acute renal and acute respiratory failure, that differed with respect to the severity of respiratory insufficiency. Group I had moderate respiratory failure (FiO2 0.31 +/- 0.10, PaO2 84 +/- 14 mmHg), and Group II had severe respiratory failure (FiO2 0.75 +/- 0.17, PaO2 77 +/- 14 mmHg). There was a significant correlation between increase in TEI (delta Z0) and decrease in body weight (delta BW) in each individual patient, but the slope of regression lines was remarkably flattened in Group II. In Group I, delta TEI was 1.9 +/- 0.9 omega…

DeltaAdultMalemedicine.medical_specialtyRespiratory TherapyPostureUltrafiltrationPulmonary EdemaHematocritCritical Care and Intensive Care MedicineCardiography ImpedanceRenal DialysisInternal medicinemedicinePlethysmographHumansAcute respiratory failurePlethysmography ImpedanceRespiratory systemAgedLungmedicine.diagnostic_testbusiness.industryBody WeightAcute Kidney InjuryMiddle AgedExtracorporeal hemodialysismedicine.anatomical_structureRespiratory failureHematocritCardiologyFemalebusinessRespiratory InsufficiencyIntensive care medicine
researchProduct

A portable electronic system for non-invasive real-time acquisition of multiple physiological signals

2019

In this work, we have designed and realised a portable and compact electronic system for the synchronous acquisition of multiple physiological signals. The system employs a Texas Instruments ADS1298 front-end with 24-bit resolution for data acquisition and supports up to 8 channels and 4 kHz sampling rate. The front-end communicates via SPI with a STM32 microcontroller which pre-processes the data and sends them through USB or Bluetooth to a suitable PC application. The system has been realized for the simultaneous acquisition of electrocardiographic (ECG) and photoplethysmographic (PPG) signals, but it can also be employed for acquiring other typologies of signals, e.g. breathing or electr…

Electrocardiographybiomedical signal processingSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaPhotoplethysmographySettore ING-INF/01 - Elettronica
researchProduct

Video-Based Heartbeat Rate Measuring Method Using Ballistocardiography

2017

International audience; Video-based heartbeat rate measurement is a rapidly growing application in remote health monitoring. Video-based heartbeat rate measuring methods operate mainly by estimating photoplethysmography or ballistocardiography signals. These methods operate by estimating the microscopic color change in the face or by estimating the microscopic rigid motion of the head/facial skin. However, the robustness to motion artifacts caused by illumination variance and motion variance of the subject poses main challenge. We present a video-based heartbeat rate measuring framework to overcome these problems by using the principle of ballistocardiography. In this paper, we proposed a b…

EngineeringMean squared errorvideo analyticsComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION02 engineering and technology01 natural sciencesStandard deviationphotoplethysmography and ballistocardiographysymbols.namesakeFacial videoRobustness (computer science)Photoplethysmogram0202 electrical engineering electronic engineering information engineeringmedicineComputer vision[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Electrical and Electronic EngineeringNoncontact[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Instrumentationmedicine.diagnostic_testbusiness.industry010401 analytical chemistryPearson product-moment correlation coefficient3. Good health0104 chemical sciencesRemote health monitoringnon-contactFeature (computer vision)BallistocardiographyFace (geometry)symbols020201 artificial intelligence & image processingArtificial intelligencebusinessIEEE Sensors Journal
researchProduct

Effect of Motion Artifact on Digital Camera Based Heart Rate Measurement

2017

International audience; Depression is one of the most prevalent mental disorders, burdening many people world-wide. A system with the potential of serving as a decision support system is proposed, based on novel features extracted from facial expression geometry and speech, by interpreting non-verbal manifestations of depression. The proposed system has been tested both in gender independent and gender based modes, and with different fusion methods. The algorithms were evaluated for several combinations of parameters and classification schemes, on the dataset provided by the Audio/Visual Emotion Challenge of 2013 and 2014. The proposed framework achieved a precision of 94.8% for detecting p…

Engineeringbusiness.product_category[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingRemote patient monitoringMotion artifact effect02 engineering and technology01 natural sciencesMotion (physics)Field (computer science)Photoplethysmography signalComputer vision[ SDV.IB ] Life Sciences [q-bio]/Bioengineering[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/ImagingDigital cameraSkinPatient monitoringDigital cameraremote health monitoringCamerasBiomedical technologyHeart rate measurement[SDV.IB]Life Sciences [q-bio]/BioengineeringArtifactsAlgorithms[ INFO ] Computer Science [cs]0206 medical engineeringHeart rateCardiology[INFO] Computer Science [cs]010309 opticsMotionDatabases0103 physical sciences[INFO]Computer Science [cs]Heart rate measurement methodPhotoplethysmographyBiomedical measurementLighting[SDV.IB] Life Sciences [q-bio]/BioengineeringArtifact (error)Digital camerasMAHNOB-HCI databasebusiness.industry020601 biomedical engineeringMotion artifacts[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/ImagingFace (geometry)FaceState (computer science)Artificial intelligencebusiness