Search results for "Plethysmography"
showing 10 items of 84 documents
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…
Bilateral photoplethysmography studies of the leg arterial stenosis.
2005
A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if compared with those of the healthy leg, were much weaker, with delayed arrival as a consequence of increased pulse wave transit time (PWTT) due to higher vascular resistance. The specific PWTT delays for the occluded legs were in the range of 20-80 ms, while in the case of healthy subjects the leg PPG…
Influence of the scalp thickness on the intracranial contribution to rheoencephalography
2004
In spite of the great efforts made by the scientific community, up to now there is no agreement about the rheoencephalography (REG) capability to reflect cerebral blood flow (CBF). Moreover, a standard procedure and the optimal electrode arrangement have not been established yet. In a previous study, we found, using a classical four-shell spherical model of the head and solving it by numerical methods that, theoretically, there could exist an electrode arrangement to register an REG II free of extracranial contribution. In this paper, we have studied the influence of scalp thickness on the intracranial contribution to REG II. The study has been performed by solving the head model, using in …
Pulse rate variability measurement with camera-based photoplethysmography
2021
Electrocardiogram (ECG) has been used by doctors and biomedical researchers to measure cardiac parameters such as Heart Rate (HR) and Heart Rate Variability (HRV). HR is a medical index for health monitoring and the HRV is a sign to reflect the activities of Autonomic Nervous System (ANS) and can be used for emotion recognition applications. Recently, remote photoplethysmography (rPPG) has evolved as a non-contact technique for measuring vital cardiac signs. Compared with ECG, this technique is non-invasive, low-cost, comfortable and possibly utilized in long-term monitoring. It has great potential in remote health assessment and emotion detection. However, the rPPG is a video-based method,…
A preliminary investigation of the effect of contact pressure on the accuracy of heart rate monitoring by wearable PPG wrist band
2019
The increase of safety and health monitor of workers has become a crucial objective to prevent excessive physical workloads, injuries, accidents and errors. Heart rate (HR) is a very important physiological indicator which could properly describe the workers’ physical status. Recently, wearable photoplethysmographic (PPG) wristband trackers have been utilized to measure HR without hindering normal gesture of workers. However, the quality of PPG signals is highly affected by human physical motions, resulting in a poor reliable HR estimation. Specifically, during different activities and gestures, PPG sensor contact pressures may have an impact on the quality of the heart rate signal. To appr…
Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters
2020
The recent advances in multiparametric monitoring of biosignals and management of big data prompt for the development of devices and techniques for the extraction of indicators with physiological relevance. In this context, we have designed and realized a portable electronic system, equipped with simple biomedical sensors, able to synchronously record multiple electrocardiographic (ECG), photoplethysmographic (PPG) and breathing signals, for carrying out a non-invasive monitoring of several cardiovascular parameters. In this work, we show the results of preliminary measurements performed following a specific physiological protocol (i.e., deep breathing with 10 s per cycle). The system allow…
Transthoracic electrical impedance during extracorporeal hemodialysis in acute respiratory failure ("Shocked Lung syndrome").
1980
The alteration (delta Z0) of transthoracic electrical impedance (TEI) during extracorporeal hemodialysis (EHD) was investigated in two Groups of patients with acute renal and acute respiratory failure, that differed with respect to the severity of respiratory insufficiency. Group I had moderate respiratory failure (FiO2 0.31 +/- 0.10, PaO2 84 +/- 14 mmHg), and Group II had severe respiratory failure (FiO2 0.75 +/- 0.17, PaO2 77 +/- 14 mmHg). There was a significant correlation between increase in TEI (delta Z0) and decrease in body weight (delta BW) in each individual patient, but the slope of regression lines was remarkably flattened in Group II. In Group I, delta TEI was 1.9 +/- 0.9 omega…
A portable electronic system for non-invasive real-time acquisition of multiple physiological signals
2019
In this work, we have designed and realised a portable and compact electronic system for the synchronous acquisition of multiple physiological signals. The system employs a Texas Instruments ADS1298 front-end with 24-bit resolution for data acquisition and supports up to 8 channels and 4 kHz sampling rate. The front-end communicates via SPI with a STM32 microcontroller which pre-processes the data and sends them through USB or Bluetooth to a suitable PC application. The system has been realized for the simultaneous acquisition of electrocardiographic (ECG) and photoplethysmographic (PPG) signals, but it can also be employed for acquiring other typologies of signals, e.g. breathing or electr…
Video-Based Heartbeat Rate Measuring Method Using Ballistocardiography
2017
International audience; Video-based heartbeat rate measurement is a rapidly growing application in remote health monitoring. Video-based heartbeat rate measuring methods operate mainly by estimating photoplethysmography or ballistocardiography signals. These methods operate by estimating the microscopic color change in the face or by estimating the microscopic rigid motion of the head/facial skin. However, the robustness to motion artifacts caused by illumination variance and motion variance of the subject poses main challenge. We present a video-based heartbeat rate measuring framework to overcome these problems by using the principle of ballistocardiography. In this paper, we proposed a b…
Effect of Motion Artifact on Digital Camera Based Heart Rate Measurement
2017
International audience; Depression is one of the most prevalent mental disorders, burdening many people world-wide. A system with the potential of serving as a decision support system is proposed, based on novel features extracted from facial expression geometry and speech, by interpreting non-verbal manifestations of depression. The proposed system has been tested both in gender independent and gender based modes, and with different fusion methods. The algorithms were evaluated for several combinations of parameters and classification schemes, on the dataset provided by the Audio/Visual Emotion Challenge of 2013 and 2014. The proposed framework achieved a precision of 94.8% for detecting p…