Search results for "Pollutant"
showing 10 items of 1389 documents
Perturbation of metabolic pathways mediates the association of air pollutants with asthma and cardiovascular diseases.
2018
Background: Epidemiologic evidence indicates common risk factors, including air pollution exposure, for respiratory and cardiovascular diseases, suggesting the involvement of common altered molecular pathways. Objectives: The goal was to find intermediate metabolites or metabolic pathways that could be associated with both air pollutants and health outcomes (“meeting-in-the-middle”), thus shedding light on mechanisms and reinforcing causality. Methods: We applied a statistical approach named ‘meet-in-the-middle’ to untargeted metabolomics in two independent case-control studies nested in cohorts on adult-onset asthma (AOA) and cardio-cerebrovascular diseases (CCVD). We compared the results …
Case study: inorganic pollutants associated with particulate matter from an area near a petrochemical plant.
2004
The area of Gela (Sicily, Italy) contains one of the largest petroleum refineries in Europe and also has several oil fields both on land and offshore. This paper discusses how the oil refinery and traffic-related air pollution affect the chemical composition of airborne particulate matter over the town of Gela, using pine needles and urban road dust as the means of survey. Forty-one samples of pine needles from Pinus halepensis (Mill.) and two composite samples of roadway dust, each subdivided into six size fractions, were analyzed for major and trace elements. Information on the natural or anthropogenic origin of the observed heavy metals was deduced from factor analysis and element distri…
Modeling of copper fixed-bed biosorption from wastewater by Posidonia oceanica
2009
Biosorption of copper from aqueous solutions by Posidonia oceanica was investigated in batch and fixed-bed experiments. Batch experiments were conducted to evaluate the removal equilibrium at pH 5.0 and 6.0; experimental data were fitted to Langmuir model with maximum uptake capacities of 56.92 and 85.78 mg g(-1), respectively. Five column experiments were carried out at different feed concentrations. Breakthrough times and continuous sorption isotherm were obtained from breakthrough curves. Differences among batch and continuous isotherms were observed; the maximum uptake capacity in dynamic conditions was found in 56.70 mg g(-1) for final pH between 5.0 and 5.5. The biosorbent was regener…
Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly
2001
The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10–800 μg l−1 of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput …
Démarche statistique pour la sélection des indicateurs par Random Forests pour la surveillance de la qualité des sols
2013
The volume of data, and the large number of biological variables to be tested (one hundred), require analytical techniques, such asRandom Forests, which can overcome the problem of multi-colinearity for the selection of indicators, sensitive to various factors.Random Forests methodology is appropriate for the selection of the most discriminant variables. So, we searched for the best wayto select them, by bringing together all biological variables, representing the Microflora and Fauna. This approach focuses on impactindicators from the Bio2 program, indicators of flora and indicators of accumulation (snails) were not included.This work has been implemented on the three factors of discrimina…
Selective determination of trimethylamine in air by liquid chromatography using solid phase extraction cartridges for sampling.
2004
Abstract The selective determination of trimethylamine (TMA) in air by liquid chromatography is reported. Sampling is effected by flushing air through C18-packed solid-phase extraction (SPE) cartridges at a flow rate of 15 mL/min for 15 min. Next, TMA is desorbed from the cartridges and injected into the chromatographic system. The analyte is then selectively retained on a precolumn ( 20 mm ×2.1 mm i.d., packed with 30 μm, Hypersil C18 phase), and derivatized on-line by injecting 9-fluorenylmethyl chloroformate (FMOC). Finally, the TMA-FMOC derivative is transferred to the analytical column ( 125 mm ×4 mm i.d., LiChrospher 100 RP18, 5 μm), and monitored at 262 nm. The method was applied to …
In tube-solid phase microextraction-nano liquid chromatography: Application to the determination of intact and degraded polar triazines in waters and…
2017
Abstract In-tube solid-phase microextraction (IT-SPME) coupled to miniaturized liquid chromatography (LC) techniques are attractive mainly due to the column efficiency improvement, sensitivity enhancement and reduction of solvent consumption. In addition, the nanomaterials based sorbents can play a key role in the improvement of the extraction efficiency taking into account their interesting physical and chemical properties. Thus, in this work the performance of IT-SPME coupled to nano LC (NanoLC) has been compared with the performance of IT-SPME coupled to capillary LC (CapLC) with similar configurations for the determination of polar triazines including their degradation products. In both…
Sub- and supercritical fluid extraction of trichloropyridinol from soil prior to immunoassay
1997
A comparative study on the extraction of TCP (3,5,6-trichloro-2-pyridinol, a metabolite of chlorpyrifos) from soil with CO2 and H2O is reported. The polarity of the analyte requires the presence of both a cosolvent (methanol) and an ion-pair reagent [(1R)-(-)-10-camphorsulfonic acid ammonium salt] for 95% extraction in 30 min when supercritical CO2 at 40 degrees C and 383 bar is used as extractant. Subcritical water (250 degrees C and 200 bar) enables complete extraction within 15 min without additives. Quantitation of the target analyte is performed by specific immunoassay using a non-commercial monoclonal antibody which provides a linear determination range between 0.005 and 5 micrograms/…
In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untrea…
2006
This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysi…
Determination of aliphatic amines in water by liquid chromatography using solid-phase extraction cartridges for preconcentration and derivatization
2001
Bond Elut C18 solid-phase extraction cartridges were used for preconcentration and pre-column derivatization with 3,5-dinitrobenzoyl chloride (DNB) of aliphatic amines in water. Conditions for analyte preconcentration and derivatization (including the volume of sample, concentration of reagent, time of reaction and pH) were investigated, using ethylamine, isopropylamine and dimethylamine as model compounds. On the basis of these studies, a rapid and sensitive method for the determination of aliphatic amines in water is presented. The analytes are retained and purified on the cartridges and then derivatized and desorbed by drawing in succession the DNB solution and acetonitrile. The collecte…