Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems
2012
The aim of this paper is to characterize oil-filled power transformers in the narrow-band power-line communication (PLC) frequency range of 50-150 kHz. A new model is proposed for such type of a transformer, in the aforementioned frequency range of interest, in order to study its influence on the signal transmission and to investigate the possibility that the PLC signal can cross the power transformer itself. The new model is simpler than those previously proposed in literature, and it can be used in the whole frequency range available for NB PLC according to the CENELEC EN 50065-1 A-band. In order to validate the model, simulation and measurement results are compared for four oil-filled po…
Multi-objective optimized management of electrical energy storage systems in an islanded network with renewable energy sources under different design…
2014
The subject addressed in this paper is the definition of some strategies for the design and the optimaized management of EES (Electrical Energy Storage) systems, for an existing islanded distribution network supplying the Island of Pantelleria (Italy) in the Mediterranean Sea. In the paper the authors have drawn interesting conclusions through the application of an efficient MO (multi-objective) optimization algorithm, the NSGA-II, minimizing the energy losses in the grid, the total electricity generation cost and the greenhouse gas emissions. The results obtained for different installation scenarios of the EES are presented and discussed, putting into evidence the technical, environmental …
An Innovative Measurement Approach for Load Flow Analysis in MV Smart Grids
2016
This paper proposes a novel measurement procedure for load flow analysis in medium voltage (MV) smart grids. The new approach is based on power measurements at low voltage (LV) side of MV/LV distribution substations. Such measurements are carried out by means of power quality analyzers. If compared with the load flow methods based on measurements at the MV side, the proposed approach has a lower cost and it offers an equally reliable measurement system. The proposed algorithm takes the basic concept of the current summation backward/forward method; some modifications are introduced to use LV load powers measurements. To this aim, the MV/LV power transformer is properly modeled and taken int…
A New Low Cost Coupling System for Power Line Communication on Medium Voltage Smart Grids
2018
This paper proposes and verifies the performance of an innovative and low cost coupling system for power line communication (PLC) on medium voltage (MV) smart grids. The coupling system makes use of the capacitive divider of the voltage detecting systems (VDSs) to inject and receive the PLC signal. VDS are usually already installed in the MV switchboards of the major electrical manufacturer all over the world according to IEC 61243-5. VDS are used to detect the presence of the mains voltage to guarantee personnel safety. An interface circuit has been developed to be connected between the PLC transceiver and the VDS socket. In this way, the PLC signal can be coupled to the MV network without…
A new methodology for distribution systems faults identification, location and characterization
2005
PurposeIdentify a new methodology for fault characterization, identification and location in electrical distribution systems, based on the use of matrix algebra.Design/methodology/approachThe developed diagnostic methodology is based on a high precision analytical model of the network using a distributed parameters representation.FindingsTest results have proved the approach to be efficient and precise, while providing a generalized quadripolar model of a line affected by the most common kinds of fault.Research limitations/implicationsGeneralization to a greater number of fault cases, experimental tests.Practical implicationsUtilities are quite interested in such items, since the new requir…
A Method to Evaluate Voltages to Earth During an Earth Fault in an HV Network in a System of Interconnected Earth Electrodes of MV/LV Substations
2008
An easy and swift method to evaluate, in a system of interconnected earth electrodes, earth potentials on earthing systems of medium-voltage/low-voltage (MV/LV) substations, in an event of single-line-to-earth fault inside a high-voltage/medium- voltage (HV/MV) station, is presented. The advantage of the method is the simplicity of the mathematical model for solving complex systems of any size with a sufficient accuracy for practical purposes. This paper shows the results of simulations, performed on networks with different extensions and characteristics, organized in easy-to-read graphs and tables. A comparison of these results with the values obtained according to the procedure explained …
Manufacturing tolerances effects on PV array energy production
2014
This paper investigates the tolerance effects of commercial photovoltaic modules in terms of electrical energy reduction of photovoltaic plants. Several commercial modules, having the same rated power, present different power tolerance values. A wide tolerance is an indicator of possible defects or differences in the production process and is responsible of remarkable reductions in the electricity production of photovoltaic plants. In this paper, thanks to the development of a suitable simulation tool, several simulations have been carried out, considering different tolerance and shading conditions for the PV array. Simulation results quantify the peak power value of the different plant con…
Synchronization techniques for power quality instruments
2004
The measurement of voltage characteristics in power systems requires the accurate estimation of the power supply frequency and signal synchronization, even in the presence of disturbances. The authors developed and tested two innovative techniques for instrument synchronization. The first is based on signal spectral analysis techniques performed by means of the Chirp-Z transform analysis. The second is a phase-locked loop (PLL) software based on a time-domain coordinate transformation and an innovative phase-detection technique. To evaluate how synchronization techniques are adversely affected by the application of a disturbing influence, experimental tests were carried out, taking into acc…
Investigating the effect of distributed generators on traditional protection in radial distribution systems
2013
The recent changes in power network structure, development in green energy technologies and increased attention on environmental concerns have led to increase the installation of renewable energy based distributed generations (DG) in distribution networks. The increasing penetration of distributed generation in the distribution power system creates new technical and economical challenges; protection is one important topic of these challenges. High penetration of DG will have unfavorable impact on the traditional protection methods; the impact depends on the number, location and size of injected DG. To ensure safe and selective protection devices coordination, the impact of DG should be take…
New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids
2013
The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…