Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid
2015
This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…
A Technique for Power Supply Harmonic Impedance Estimation Using a Controlled Voltage Disturbance
2002
A method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. As the technique employs controlled power electronic devices it may be used as a stand alone piece of a portable measurement equipment, or it may be embedded into the functions of an active shunt filter for improved harmonic control. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the measurement technique is highly accurate and effective.
Experimental Analysis of Power Quality Issues in a Mobile House supplied by Renewable Energy Sources
2007
This paper presents the results of an experimental analysis performed on a renewable hybrid system in order to evaluate the power quality of its electrical power network, which can be influenced by three factors: the variations in the power supplied by renewable energies due to the meteorological conditions, the adopted inverter and its control strategy, which is very meaningful for the performance of the whole system, the presence of non linear loads, which in recent years have dramatically increased. The results of the experimental analysis of the power quality parameters are presented in detail and investigated also with regard to European technical standards. The main parameters which h…
Measurement issues on harmonic analysis according to the IEC 61000-4-7
2022
The objective of this article is an analysis of measurement issues related to the implementation of digital signal processing techniques for harmonic analysis, by means of FFT algorithm with different interpolation algorithms (linear, quadratic and cubic) and different sampling rates. A comparative analysis is made on errors on harmonics measurement obtained in the various case study analyses. Such errors are compared with the IEC 61000-4-7 limits. The study is supported by both simulation and experimental tests; these last are performed with different acquisition boards for signals acquisition.
A single-point approach based on nonactive power factor for the assessment of harmonic distortion sources in power systems
2022
This paper presents a study on the use of power factor indicators for the assessment of harmonic distortion sources in power systems. In detail the analysis is focused on the comparison between the proposed nonactive power factor (Q1/N) and the indicators of the IEEE Std. 1459-2010, and on the indicators feasibility in identifying the presence of harmonic distortion sources. As discussed in the paper, the proposed indicator can be evaluated with good accuracy, by means of typical power quantities measurements at the point of common coupling (PCC). Thus its measurement can be feasibly implemented in commercial platforms used for smart metering applications. To verify the proposal validity, s…
Evaluation of the power quality from a seawave power farm for different interconnection schemes
2007
In this paper we present an approach to the interconnection of a seawave power farm to the grid The generator type used in the farm is a Permanent Magnet (PM) linear generator driven from the seawaves that generates, therefore, highly distorted emfs. We propose and compare two possible ways to interconnect the farm to the grid. One is based on an approach where for each generator there is a conversion subsystem that permits the direct connection of each generator to the a.c. network, the other one is based on an ac.-d.c. converter that is connected to the generator, the converter is connected to a dc link that can receive the power from every unit and that can supply a dc-ac converter direc…
A low cost and easy re-configurable instrument for power quality survey
2004
In this document the development of a low cost and user friendly PC-based instrument for power quality measurement is proposed, according to IEC 61000-4-7 and standard IEC 61000-4-30. It is an easily re-configurable instrument able to measure harmonics, interharmonics and amplitude disturbances and supply unbalance. In order to verify its accuracy, the instrument has been tested according standard test procedures, by means of a built-up calibration test bench.
Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010
2020
The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …
Measurement uncertainty impact on simplified load flow analysis in MV smart grids
2018
This work is focused on the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. In more detail, the paper presents the uncertainty evaluation of a simplified load flow algorithm, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). To reduce the costs of the monitoring system, the load flow algorithm makes use of LV load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on the algorithm input quantities (load powers and slack b…
Uncertainty management in the measurements for the electric power quality analysis
2014
The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors combine and propagate through the measurement chain, four approaches are proposed and validated. These approaches entail a greater and greater uncertainty overestimation, but, at the same time, require less and less time and resources. Therefore, the four methodologies are perfectly adequate for the implementation of the PUMA (Procedure for Uncertainty Management) metho…