Search results for "Power supply"
showing 10 items of 38 documents
A fuel cell-battery hybrid power supply for portable applications
2010
Today, academic and industrial research is addressed to fuel cell based hybrid power supply in many fields of applications including stationary, automotive and portable electronics. Increasing source runtime, speeding up the transient response while minimizing weight, volume and cost of the power supply system are key requirements of all applications. According to the particular application, the power management system is optimized for a specific feature. In this paper, a fuel cell–battery hybrid power supply for a Digital Camera is proposed, although the control algorithm can be efficiently applied to any portable device. Thanks to an innovative control on the input power, any fuel cell pr…
UPS fuel cell based: An innovative back-up system
2007
The aim of the paper is to evaluate the technical feasibility and aspects related to the use, in an Uninterruptible Power Supply (UPS), of fuel cells instead of traditional electrochemical batteries. The proposed system, named UPS-FCB (Fuel Cell Based) presents a modular and versatile system configuration; particularly it is possible to integrate it with traditional UPS. Moreover the system features can be modified in terms of power, reliability, back-up time, etc., by changing the power devices. A detailed experimental analysis has been carried out on a passive stand-by UPS integrated with a FCB; experimental results can be easily extended to the other possible system architectures. © 2007…
Measurement-based load modelling for power supply system design
2008
Load modelling is essential to simulate system features as closely as possible to the effective behaviour. In spite of model complexity, the need for accuracy often leads to a component-based approach, i.e. the analysis of load internal subsystems. It is a common belief that measurement-based load models lead to low accuracy. This paper presents a new, high-accuracy measurement-based load modelling approach to define a power consumption profile load model for power systems design. The load modeling technique is described by an application. Simulation and experimental results are compared. The efficiency and portability of the proposed modelling approach is discussed. ©2008 IEEE.
Optimized Topology for High Efficiency Battery Discharge Regulator
2008
In the following years power levels of 20 kW to 50 kW will be demanded by the telecommunication satellites. It is not possible to keep 0.5 kW modules with up to 100 modules in parallel and, therefore, higher power modules must be used. A higher bus voltage seems also necessary and any voltage below 150 V and above 100 V could meet the needs. In addition, new optimized topologies that process only a part of the total power delivery can be employed to improve the efficiency. In this article, design guidelines and experimental results of a high efficiency battery discharge regulator (BDR) module based on parallel power processing are given.
A novel fuel cell-based power system modeling approach
2013
Nowadays, fuel cells are the most promising source of energy for stationary applications. Unfortunately, the power density of fuel cells is not adequate for modern applications. A fuel cell - based hybrid power supply is required. The fuel cell is coupled with a high-energy density power source to improve performances of the composite power source. A power management stage is introduced between the two basic sources to control the power flow path from the fuel cell to the auxiliary source and the load. In order to avoid effects of a limited power density of the fuel cell on the whole power supply, sophisticated power management algorithms are implemented. Accurate modeling is required to te…
A Technique for Power Supply Harmonic Impedance Estimation Using a Controlled Voltage Disturbance
2002
A method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. As the technique employs controlled power electronic devices it may be used as a stand alone piece of a portable measurement equipment, or it may be embedded into the functions of an active shunt filter for improved harmonic control. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the measurement technique is highly accurate and effective.
Small-Signal Modeling of a Controlled Transformer Parallel Regulator as a Multiple Output Converter High Efficient Post-Regulator
2004
This paper presents a post-regulator based on the use of a controlled transformer, which adds or subtracts an additional voltage to the output filter of a converter in order to regulate its output voltage. So, their actuation is complementary to that of more known post-regulators, such as the magnetic amplifier (magamp) and synchronous switch post-regulator (SSPR), because the regulation is achieved by controlling the voltage across the filter inductor instead of its charge time. Besides, the post-regulator processes the power in parallel to the one flowing from input to output and only handles a percentage of it. The post-regulation by controlled transformer is suitable of being employed i…
Estimation of power supply harmonic impedance using a controlled voltage disturbance
2002
A novel method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the effectiveness of this measurement technique.
Self-Heating Induced Instability of a Non-Linear Inductor in a SMPS: a Case Study
2023
This paper proposes a case study to show that the non-linear operation of a power inductor in a SMPS can induce instability of the control system leading to overheating of the inductor beyond its allowable temperature and to an excessive peak of the maximum current. The case study is performed by a commercial ferrite inductor employed in a synchronous boost converter encompassing a control system to adjust the duty cycle, assuring a constant output voltage. The thermal transient is described by the time domain waveforms and thermal images.
Computer Aided Optimal Design of High Power Density EMI Filters
2016
Power density of power converter systems is becoming an increasingly stringent design constraint for a wide range of applications. Size reduction of EMI filter in power converters is an important aspect due to its significant impact on the overall converter volume and weight. In order to take on this issue, a computer aided procedure for a fast selection of optimal discrete EMI filter components and configuration is described in this paper. The proposed technique is a rule-based automatic procedure based on suitable databases that consider datasheets information of commercially available passive components (e.g. magnetic cores, capacitors). It allows the minimization of the filter's volume …