New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids
2013
The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…
Measurement Issues for the Characterization of Medium Voltage Grids Communications
2013
This paper is focused on the measurement issues and procedures for the characterization of medium voltage grids for narrowband power line communications (NB-PLCs), in the perspective of the use and integration of such technology into smart grids communication networks. The fundamentals are given for the characterization of the PLC channel, by means of noise and attenuation measurements. Suitable procedures are also developed for the characterization and modeling of the power system components in the frequency range of interest. Furthermore, the complete model of the PLC system is experimentally validated in a real case study.
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards
2011
This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.
A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization
2012
This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid
2015
This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…
Narrowband power line communications for medium voltage smart grids
2014
The aim of the paper is to show how narrowband power line communications (NB-PLCs) can be a valid solution for medium voltage grids. Advantages and drawbacks of this solution are analyzed, starting from some experimental communication results, which were carried out on the medium power system networks of the islands of Ustica and Favignana, in the presence of the net voltage. Furthermore, some communication architectures and hardware prototypes based on NB-PLCs are proposed for different smart grids applications.
A Technique for Power Supply Harmonic Impedance Estimation Using a Controlled Voltage Disturbance
2002
A method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. As the technique employs controlled power electronic devices it may be used as a stand alone piece of a portable measurement equipment, or it may be embedded into the functions of an active shunt filter for improved harmonic control. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the measurement technique is highly accurate and effective.
Development of a Coupling System for Medium Voltage Power Line Communication in the CENELEC A Frequency Band
2016
In this paper the performances of a new power line communication (PLC) coupling system for medium voltage (MV) smart grids are investigated in the CENELEC A frequency band (i.e. 3 - 95 kHz). The new coupling solution is based on the use of the capacitive divider of the voltage detecting system (VDS) as PLC coupler to the MV network. According to IEC 61243-5, VDS are worldwide used to reveal the presence of the mains voltage to ensure the safety of the operators. A proper interface circuit has been invented and patented to couple the PLC signal through the VDS. In this way no dedicated MV PLC coupler is required, thus avoiding the related costs of the coupler, of its installation, and those …