Development of bidirectional dc-dc converters for hybrid power sources - Final Report
2018
A Bidirectional Isolated Full-Bridge Converter was designed, prototyped and tested. The device is intended to interface a Bank of Supercapacitors with a battery-powered bus, in order to boost the capability of supplying large power peaks. The converter was based on the Isolated Dual Active Bridge configuration. When driven by an external control voltage, it is capable of generating in both directions a train of current pulses, with 2kW peak power, for any battery voltage in the range 24-32V and for any supercapacitor voltage in the range 35-70V. Worst-case battery current was 70A. Pulse duration was 100ms with 50% duty cycle and 1 ms rise time.
A Power Law Behavior in the Incentivized Italian Photovoltaic Market
2018
The Italian photovoltaic (PV) marketis analyzed by using the data contained in the database that describes all PV Plants installed in Italy under the incentive program called “2nd Conto Energia”. It is shown that the cumulative probability distribution of the size of the installed PV plants has a broken power tail. An approach to partially quantify the effect of the economic, juridical and technical rules is introduced in order to show how the regulatory body influences the power tail of the cumulative probability curve.
Caratterizzazione e modellizzazione di un sistema di comunicazione power line in media tensione
2011
Comportamento dei trasformatori MT/BT in sistemi di comunicazione power line. Caratterizzazione e modellizzazione
2012
“Coupling interfaces for communication transceivers over power lines”
2010
Coupling circuit for power line communications
2013
A coupling interface couples a transceiver to one or more capacitive voltage dividers of a power transmission system. The coupling interface includes a first signal path including an adjustable inductance configured to form a resonance circuit with a capacitance associated with the one or more capacitive voltage dividers. The coupling interface may include a second signal path including an adjustable inductance configured to form a resonance circuit with the capacitance associated with the one or more capacitive voltage dividers.
An Innovative Coupling Solution for Power Line Communication in MV Electrical Networks
2019
One of the main problems in the diffusion of power line communication (PLC) in medium voltage (MV) networks is the need of a dedicated PLC coupler to be installed all over the network. To avoid this problem, the authors have studied, prototyped and patented an innovative PLC coupling solution which uses electrical elements embedded in most of the switchgears already installed in MV networks, i.e. the capacitive dividers of the voltage detecting systems (VDS). The new solution prototype is described in this paper, highlighting the advantages in terms of a significant reduction of both direct costs of equipment and infrastructures and indirect costs of installation and service interruption. T…
Model of line to shield power line communication system on a Medium Voltage network
2010
In this paper a complete model of a power line communication (PLC) system on a Medium Voltage (MV) network is presented in the case of a line-ground configuration. A simple and friendly Simulink (R) software is used to develop the model. A distributed parameter MV cable model in line-ground configuration is considered together with the power transformers, the signal coupling networks and the receiving and transmitting line coupling interface of a ST7540 FSK powerline transceiver. The performances of the complete PLC communication system are evaluated for different line lengths by means of the attenuation computed as ratio between the received and transmitted voltage signals.
Power Line Communication in Medium Voltage Systems: Characterization of MV Cables
2008
The aim of this paper is to illustrate the development of a theoretical and experimental study on the characterization of medium voltage (MV) cables in the frequency range 25-200 kHz. Two transmission line configurations, line-ground and line-line, were considered in order to evaluate the main parameters, such as the characteristic impedance and the attenuation constant alpha. A simplified model of the line-ground configuration is proposed which allows one to evaluate the characteristic impedance and the attenuation constant by means of geometrical dimensions. The model was verified by experimental measurements on commonly used MV cables, RG7H1R, with an aluminium core of different sections…
Simulation of a Power Line Communication System in Medium and Low Voltage Distribution Networks
2011
The aim of the paper is to study the influence of the power transformer on signal transmission in the case of a power line communication (PLC) system in a overhead Medium Voltage (MV) power network. A model of the PLC system was carried out by means of the Simulink® software. A distributed parameter MV overhead line, two power transformers, the signal coupling networks and the receiving and transmitting line coupling interface of a ST7540 FSK powerline transceiver were included in the model. The performances of the complete PLC communication system are evaluated for different line lengths by means of the attenuation computed as ratio between the received and transmitted voltage signals.