Search results for "PreP"
showing 10 items of 1334 documents
Repair bond strength of composite : effect of surface treatment and type of composite
2017
Background By an increase in use of composite restorations, some defects are also seen in these restorations, which need to be repaired. Since complete replacement of an old restoration may compromise the tooth structure, repair of defect is a more practical approach if there is no caries recurrence. Risk of pulp injury also decreases as such. One major challenge in restoration repair is to obtain a durable bond between the new and old composite. Laser irradiation has been suggested for surface preparation of old composite. This study aimed to assess the effect of composite surface preparation with Er,Cr:YSGG laser on microtensile bond strength to new composite. Material and methods A total…
Validation of a method for the determination of boron in ceramic materials by X-ray fluorescence spectrometry
2000
Abstract A method is proposed for boron determination in ceramic materials, boracic raw materials and ceramics frits of different compositions by wavelength dispersive X-ray fluorescence technique. The instrumental conditions were studied and the sample preparation procedures were optimized. The reference method used was the potentiometric titration of mannitol–boric complex acid and the technique was optimized for the determination of B 2 O 3 in each of the materials used. The samples for XRF determination were obtained as pellets and as glass discs. For the pellets different binders were studied, such as mannitol and cellullose for the samples of raw materials, and polyvinylpirrolidone an…
Recent advances and potential applications of modulated differential scanning calorimetry (mDSC) in drug development.
2016
Differential scanning calorimetry (DSC) is frequently the thermal analysis technique of choice within preformulation and formulation sciences because of its ability to provide detailed information about both the physical and energetic properties of a substance and/or formulation. However, conventional DSC has shortcomings with respect to weak transitions and overlapping events, which could be solved by the use of the more sophisticated modulated DSC (mDSC). mDSC has multiple potential applications within the pharmaceutical field and the present review provides an up-to-date overview of these applications. It is aimed to serve as a broad introduction to newcomers, and also as a valuable refe…
Drug release from alpha,beta-poly(N-2-hydroxyethyl)-DL-aspartamide-based microparticles.
2004
Abstract Spherical pH-sensitive microparticles have been prepared by reverse phase suspension polymerization technique. Starting polymer has been α , β -poly( N -2-hydroxyethyl)- dl -aspartamide (PHEA) partially derivatized with glycidylmethacrylate (GMA). PHEA-GMA copolymer (PHG) has been crosslinked in the presence of acrylic acid (AA) or methacrylic acid (MA) at various concentration. The obtained microparticles have been characterized by FT-IR spectrophotometry, particle size distribution analysis and scanning electron microscopy. In order to have information about water affinity of the prepared samples, swelling measurements have been carried out in aqueous media which simulate some bi…
Preparation, characterization and in vitro antimicrobial activity of ampicillin-loaded polyethylcyanoacrylate nanoparticles.
1998
In this paper, the experimental conditions for preparing ampicillin-loaded polyethylcyanoacrylate (PECA) nanoparticles are described. The effects of drug concentration and surfactant type in the polymerization medium on the particle size distribution and loading capacity were studied. The results of these studies show that only the type of surfactant has an impact on the nanoparticle dimensions. The release rate of ampicillin from PECA nanoparticles at pH 7.4 (extracellular value pH) performed either with and without esterases, show that the drug release is considerably increased in the presence of these exzymes. The results of drug release study at pH 1.1 (simulated gastric juice) are very…
Nanocapsules with specific targeting and release properties using miniemulsion polymerization.
2013
The field of application for nanosized materials ranges from mere technical purposes to a growing field of applications in biomedicine. Among the different techniques and processes to produce these materials for encapsulation of reporter molecules and drugs, the miniemulsion process has been proven to be highly adaptable to these specific needs.The review covers the recent developments in the field of miniemulsion as a very powerful technique for the formation of complex carriers for the encapsulation of different kinds of reporter molecule and drugs. The use of a wide variety of polymerization techniques in the miniemulsion process and possible utilization of a wide range of monomers as re…
The pore structure of compacted and partly saturated MX-80 bentonite at different dry densities
2014
Compacted MX-80 bentonite is a potential backfill material in radioactive-waste repositories. Pore space in MX-80 has been the subject of considerable debate. 3D reconstructions of the pore space based on tomographic methods could provide new insights into the nature of the pore space of compacted bentonites. To date, few such reconstructions have been done because of problems with the preparation of bentonite samples for electron microscopy. The nanoscale intergranular pore space was investigated here by cryo-Focused Ion Beam nanotomography (FIB-nt) applied to previously high-pressure frozen MX-80 bentonite samples. This approach allowed a tomographic investigation of the in situ microstru…
Effect of cavity preparation instruments (oscillating or rotating) on the composite-dentin interface in primary teeth.
2003
Abstract Objectives: To evaluate the effect of preparation of instruments on the interfacial integrity between cavity wall and composite restoration. Methods: Two class II slot preparations were done in 10 primary teeth either with SonicSys® or with a conventional bur. The cavities were filled using an adhesive system. One layer of a flowable composite and one layer of a condensable composite were applied. The specimens were analyzed by confocal laser scanning microscopy. Results: In the SonicSys® group the mean thickness of the hybrid layer was 6.12 (0.60) μm; in the control group it was 6.04 (0.63) μm. The difference was not statistically significant. Two fractures were observed in one to…
Shear bond strength of orthodontic metal brackets to aged composite using three primers
2017
Background This study aimed to assess the effect of surface preparation with sandblasting and diamond bur along with the use of three primers on shear bond strength (SBS) of metal brackets to aged composite. Material and methods In this in vitro, experimental study, 60 Filtek Z250 composite discs were fabricated (10×2mm), immersed in distilled water for 24 hours and subjected to 5000 thermal cycles. They were randomly divided into two groups (n=30) of sandblasting with aluminum oxide particles for 10 seconds and surface roughening with bur. Each group was randomly divided into three subgroups (n=10) for use of Transbond XT, Assure Plus and Composite Primer. Metal brackets were bonded and th…
Influence of cavity preparation technique (rotary vs. ultrasonic) on microleakage and marginal fit of six end-root filling materials
2010
Objectives: To evaluate in vitro the effect of cavity preparation with microburs and diamond-coated ultrasonic tips on the microleakage and marginal fit of six end-root filling materials. Study Design. The following materials were assessed: amalgam (Amalcap), zinc oxide eugenol (IRM), glass ionomer (Vitrebond), compomer (Cavalite), mineral particle aggregate (MTA) and composite (Clearfil). Cavity preparation was performed with microburs or diamond ultrasonic tips in single-root teeth. The seal was evaluated in two experiments: a microleakage assay on the passage of dye to the interface; and a scanning electron microscopy study and analysis of epoxy resin replicas, measuring the size of gaps…