Search results for "Precision"
showing 10 items of 448 documents
Precise half-life measurement of the Si-26 ground state
2008
The beta-decay half-life of 26Si was measured with a relative precision of 1.4*10e3. The measurement yields a value of 2.2283(27) s which is in good agreement with previous measurements but has a precision that is better by a factor of 4. In the same experiment, we have also measured the non-analogue branching ratios and could determine the super-allowed one with a precision similar to the previously reported measurements. The experiment was done at the Accelerator Laboratory of the University of Jyvaskyla where we used the IGISOL technique with the JYFLTRAP facility to separate pure samples of 26Si.
Ground and excited state charmonium production inp+pcollisions ats=200 GeV
2012
We report on charmonium measurements [J/psi (1S), psi' (2S), and chi(c) (1P)] in p + p collisions at root s = 200 GeV. We find that the fraction of J/psi coming from the feed-down decay of psi' and chi(c) in the midrapidity region (vertical bar y vertical bar < 0: 35) is 9.6 +/- 2.4% and 32 +/- 9%, respectively. We also present the p(T) and rapidity dependencies of the J/psi yield measured via dielectron decay at midrapidity (vertical bar y vertical bar < 0.35) and via dimuon decay at forward rapidity (1.2 < vertical bar y vertical bar < 2.2). The statistical precision greatly exceeds that reported in our previous publication [Phys. Rev. Lett. 98, 232002 (2007)]. The new results are compare…
Improved $K_{e3}$ radiative corrections sharpen the $K_{\mu 2}$--$K_{l3}$ discrepancy
2021
The measurements of $V_{us}$ in leptonic $(K_{\mu 2})$ and semileptonic $(K_{l3})$ kaon decays exhibit a $3\sigma$ disagreement, which could originate either from physics beyond the Standard Model or some large unidentified Standard Model systematic effects. Clarifying this issue requires a careful examination of all existing Standard Model inputs. Making use of a newly-proposed computational framework and the most recent lattice QCD results, we perform a comprehensive re-analysis of the electroweak radiative corrections to the $K_{e3}$ decay rates that achieves an unprecedented level of precision of $10^{-4}$, which improves the current best results by almost an order of magnitude. No larg…
Mass measurements on neutron-deficient Sr and neutron-rich Sn isotopes with the ISOLTRAP mass spectrometer
2005
Abstract The atomic masses of 76,77,80,81,86,88 Sr and 124,129,130,131,132 Sn were measured by means of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. 76 Sr is now the heaviest N = Z nucleus for which the mass is measured to a precision better than 35 keV. For the tin isotopes in the close vicinity of the doubly magic nucleus 132 Sn, mass uncertainties below 20 keV were achieved. An atomic mass evaluation was carried out taking other experimental mass values into account by performing a least-squares adjustment. Some discrepancies between older experimental values and the ones reported here emerged and were resolved. The results of the new adjustment and their impact will be pr…
Theory for muon-electron scattering @ 10ppm: A report of the MUonE theory initiative
2020
We review the current status of the theory predictions for elastic μ-e scattering, describing the recent activities and future plans of the theory initiative related to the proposed MUonE experiment.
QValues of the SuperallowedβEmittersAlm26,Sc42, andV46and Their Impact onVudand the Unitarity of the Cabibbo-Kobayashi-Maskawa Matrix
2006
The $\ensuremath{\beta}$-decay ${Q}_{\mathrm{EC}}$ values of the superallowed beta emitters $^{26}\mathrm{Al}^{m}$, $^{42}\mathrm{Sc}$, and $^{46}\mathrm{V}$ have been measured with a Penning trap to a relative precision of better than $8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}$. Our result for $^{46}\mathrm{V}$, 7052.72(31) keV, confirms a recent measurement that differed from the previously accepted reaction-based ${Q}_{\mathrm{EC}}$ value. However, our results for $^{26}\mathrm{Al}^{m}$ and $^{42}\mathrm{Sc}$, 4232.83(13) keV and 6426.13(21) keV, are consistent with previous reaction-based values. By eliminating the possibility of a systematic difference between the two t…
SpecTrap: precision spectroscopy of highly charged ions—status and prospects
2013
We present the status of the SpecTrap experiment currently being commissioned in the framework of the HITRAP project at GSI, Darmstadt, Germany. SpecTrap is a cryogenic Penning trap experiment dedicated to high-accuracy laser spectroscopy of highly charged ions (HCI) near rest. Determination of fine structure and hyperfine structure splittings in HCI with an expected relative spectral resolution of 10−7 will offer the possibility to test quantum electrodynamics in strong fields with unprecedented accuracy. Recently, we have demonstrated trapping and laser Doppler cooling of singly charged magnesium ions in SpecTrap. We report on the status of the experimental apparatus, measurements and pre…
Hyperfine measurements in a storage ring
1995
Starting with a look at the outstanding role of the hydrogen atom in modern physics, this work reviews aspects of an extension of precision spectroscopy to the ground-state hyperfine structure of highly charged hydrogenic ions. In this connection, the preferences of heavy-ion storage rings are outlined and illuminated by the laser-spectroscopic measurement (the first of that kind) of the 1s hyperfine splitting of 209Bi82+, stored in the heavy-ion storage ring at GSI. The experimental results, including the mean lifetime of the upper 1s substate, are compared with the presently available theoretical calculations. The relevance of studying further hydrogenicc ions in the vicinity of the doubl…
A crop field modeling to simulate agronomic images
2010
In precision agriculture, crop/weed discrimination is often based on image analysis but though several algorithms using spatial information have been proposed, not any has been tested on relevant databases. A simple model that simulates virtual fields is developed to evaluate these algorithms. Virtual fields are made of crops, arranged according to agricultural practices and represented by simple patterns, and weeds that are spatially distributed using a statistical approach. Then, experimental devices using cameras are simulated with a pinhole model. Its ability to characterize the spatial reality is demonstrated through different pairs (real, virtual) of pictures. Two spatial descriptors …
Optical Characterization Method for Tilted or Decentered Intraocular Lenses
2016
Purpose To test and validate a method for measuring the optical quality and optical power of monofocal intraocular lenses (IOLs) in the presence of a tilt or a decentration as well as its optical power. Methods The experimental system consists of an artificial eye (wet-cell) and a commercial aberrometer with a Shack-Hartmann sensor. Optical image quality parameters such as point spread function (PSF), modulation transfer function (MTF), and the simulations of the retinal image of an extended object are computed from the in vitro wavefront data of an IOL. Repeatability and reproducibility of the system are tested. Mathematical and ray-tracing simulations are used to ascertain the precision a…