Search results for "Precontrast"
showing 5 items of 5 documents
Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP.
2002
Purpose To develop and test a saturation-recovery TrueFISP (SR-TrueFISP) pulse sequence for first-pass myocardial perfusion imaging. Materials and Methods First-pass magnetic resonance imaging (MRI) of Gd-DTPA (2 mL) kinetics in the heart was performed using an SR-TrueFISP pulse sequence (TR/TE/α = 2.6 msec/1.4 msec/55°) with saturation preparation TD = 30 msec before the TrueFISP readout. Measurements were also performed with a conventional saturation-recovery TurboFLASH (SRTF) pulse sequence for comparison. Results SR-TrueFISP images were of excellent quality and demonstrated contrast agent wash-in more clearly than SRTF images. The signal increase in myocardium was higher in SR-TrueFISP …
Bolus-enhanced renal spiral CT: technique, diagnostic value and drawbacks
1994
Abstract In addition to pre- and postcontrast renal CT scans, early bolus-enhanced spiral scans during demarcation of the corticomedullary junction were acquired in 85 patients. The diagnostic value and drawbacks of the three imaging series in the evaluation of renal disease were assessed. Renal calcifications and calculus disease detected at precontrast scans (18%) were obscured after contrast administration and excretion in most cases. In the detection of renal lesions bolus-enhanced spiral CT and delayed postcontrast scans had an identical diagnostic yield (94%). Bolus-enhanced spiral CT was superior in the assessment of lesion vascularity and vascular anatomy as well as opacification of…
Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions : results of a mu…
2008
The purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions. Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based on a blinded reading. The average diagnostic accuracy across the three bli…
Hepatic enhancement in cirrhosis in the portal venous phase: what are the differences between gadoxetate disodium and gadobenate dimeglumine?
2020
Purpose: To compare the level of parenchymal and portal venous enhancement in the portal venous phase (PVP) in cirrhotic patients undergoing gadoxetate disodium- and gadobenate dimeglumine-enhanced MRI. Methods: In this retrospective study, 84 cirrhotic patients (mean age ± SD: 66 ± 13 years) who underwent contrast-enhanced MRI with both gadoxetate disodium and gadobenate dimeglumine between 2012 and 2018 were included. Two readers measured signal intensities of hepatic parenchyma, portal vein and psoas muscle on precontrast and PVP. Relative enhancement (RE), image contrast, and portal vein-to-liver contrast difference were calculated. Intraindividual differences were compared with the Wil…
Qualitative and quantitative evaluation of solitary thyroid nodules with contrast-enhanced ultrasound: initial results
2005
To assess the feasibility of contrast-enhanced ultrasound (CEUS) of the thyroid gland and to evaluate the potential of this method for characterising solitary thyroid nodules.18 patients affected by solitary thyroid nodules (size range: 0.6 to 3.6 cm; mean: 1.8 cm) confirmed by surgery (nine papillary carcinomas, four follicular carcinomas, three hyperplasias, one follicular adenoma and one Plummer’s adenoma) underwent pulse inversion US at low M.I. (0.06 to 0.08) after i.v. injection of a 2.4-mL bolus of SonoVue. Baseline echogenicity and the dynamic enhancement pattern of each nodule, in comparison with adjacent thyroid parenchyma, were assessed. Signal intensity values on grey-scale imag…