Search results for "Pressure"
showing 10 items of 4493 documents
Supercritical fluid extraction of pesticides
1989
The extraction behaviour of 10 μg samples of five pesticides and some related compounds from glass wool with supercritical CO2 has been investigated under several conditions (10 MPa, 20 MPa extraction pressure, 313 K, dry and water saturated CO2). The extraction fluid was decompressed over a line of little columns, filled with 3μ Si60 or RP18, and the amount of deposited material was analyzed by HPLC for each of these columns. Due to the progressive pressure/density reduction along the line, the solubility diminishes and hence the compounds are deposited according to their polarity/vapor pressure earlier or later on the line. Thus extraction and prefractionation of compounds of different po…
Determination of α-Tocopherol in Plasma by High Performance Liquid Chromatography with Fluorescence Detection and Stability of α-Tocopherol under Dif…
2011
In order to study the clinical effects of the antioxidant alpha-tocopherol (tocofersolan, CAS 30999-06-5) a simple, robust, sensitive and reliable high performance liquid chromatography (HPLC) method using fluorescence detection for the daily measurement of alpha-tocopherol concentration in plasma is described. Several methods of HPLC analysis using fluorescence techniques are published, however, investigations of the stability of alpha-tocopherol during sample preparation under different conditions are relevant in the routine measurements and have to date not been reported. Therefore a modified method, both sensitive and robust, qualified for the day-by-day measurement of alpha-tocopherol …
Separation of selected peptides by capillary electroendoosmotic chromatography using 3 μm reversed-phase bonded silica and mixed-mode phases
1999
The retention behaviour and selectivity of selected basic, neutral and acidic peptides have been studied by capillary electroendoosmotic chromatography (CEC) with Hypersil C8, C18, Hypersil mixed-mode, and Spherisorb C18/SCX columns, 250 (335) mm x 100 microns, packed with 3 microns particles, and eluted with mobile phases composed of acetonitrile-triethylamine-phosphoric acid (TEAP) at pH 3.0 using a Hewlett-Packard Model HP3DCE capillary electrophoresis system. The selected peptides were desmopressin (D), two analogues (A and B) of desmopressin, oxytocin (O) and carbetocin (C). The peptides eluted either before or after the electroendoosmotic flow (EOF) marker, depending on the concentrat…
A theoretical plate model accounting for slow kinetics in chromatographic elution.
2011
The chromatographic elution has been studied from different perspectives. However, in spite of the simplicity and evident deficiencies of the plate model proposed by Martin and Synge, it has served as a basis for the characterization of columns up-to-date. This approach envisions the chromatographic column as an arbitrary number of theoretical plates, each of them consisting of identical repeating portions of mobile phase and stationary phase. Solutes partition between both phases, reaching the equilibrium. Mobile phase transference between the theoretical plates is assumed to be infinitesimally stepwise (or continuous), giving rise to the mixing of the solutions in adjacent plates. This yi…
Insect immunity. Constitutive expression of a cysteine-rich antifungal and a linear antibacterial peptide in a termite insect
2001
0021-9258 (Print) Journal Article Research Support, Non-U.S. Gov't; Two novel antimicrobial peptides, which we propose to name termicin and spinigerin, have been isolated from the fungus-growing termite Pseudacanthotermes spiniger (heterometabole insect, Isoptera). Termicin is a 36-amino acid residue antifungal peptide, with six cysteines arranged in a disulfide array similar to that of insect defensins. In contrast to most insect defensins, termicin is C-terminally amidated. Spinigerin consists of 25 amino acids and is devoid of cysteines. It is active against bacteria and fungi. Termicin and spinigerin show no obvious sequence similarities with other peptides. Termicin is constitutively p…
Improvement of peak shape and separation performance of beta-blockers in conventional reversed-phase columns using solvent modifiers.
2003
A comparative study of peak shape, elution behavior, and resolution of 16 beta-blockers (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol, and timolol) chromatographed with hybrid mobile phases of triethylamine (TEA)-acetonitrile and sodium dodecyl sulfate (SDS)-propanol is performed using conventional reversed-phase columns and isocratic elution. Both solvent modifiers (TEA and SDS) prevent the interaction of the basic drugs with the alkyl-bonded phase. However, the protection mechanisms of silanols on the packing are different. Whereas TEA associates with the silanol sites (b…
Comparative study of capillary electroendosmotic chromatography and electrically assisted gradient nano-liquid chromatography for the separation of p…
2000
Capillary electroendoendosmotic chromatography (CEC), being a hybrid of high-performance liquid chromatography (HPLC) and capillary electrophoresis, offers considerable changes to enhance column efficiency, speed of analysis and additional selectivity as compared to the parent methods. The analytes are driven by the electroendosmotic flow (EOF) and separated by surface-solute interactions as well as by differences in electromigration. In this paper on the separation of peptides on C18 reversed-phase and mixed-mode (sulphonic acid-n-alkyl) packings in CEC and electrically assisted reversed-phase gradient nano-LC are investigated. It is shown that mixed mode packings generate a higher EOF tha…
Comparative study of Zorbax Bio Series GF 250 and GF 450 and TSK-Gel 3000 SW and SWXL columns in size-exclusion chromatography of proteins.
1988
Abstract A reduction of the mean particle diameter of silica-based packings in the size-exclusion chromatography (SEC) of proteins to about 5 μm generates the expected increase in column plate number over the traditional 10 μm SEC columns, as demonstrated for the Zorbax Bio Series GF 250 and GF 450 and TSK-Gel 3000 SWXL columns. The slightly lower column efficiency of the TSK-Gel 3000 SWXL compared with the GF 250 column is compensated by the fact that the phase ratio of the 3000 SWXL column is higher by a factor of two. Hence both columns show nearly the same peak capacity of about 20–30. When the ionic strength of the eluent was changed by varying the salt concentration, the elution volum…
An automatic multidimensional chromatography system for purification of human uterine progesterone receptor and induction of polyclonal antibodies.
1986
Abstract This paper reports on the synthesis of Org2058-bonded microparticulate silicas and their use in affinity chromatography as the first step for the purification of human progesterone receptor. The development of microprocessor-controlled instruments allows all the various steps to be performed automatically. The various steps used for the purification of human progesterone receptor were carried out with the FPLC system: (1) affinity chromatography, (2) desalting of eluate on Sephadex G-25, (3) anion-exchange chromatography using a Mono Q column. With this procedure the receptor was purified approx. 10,000-fold within 24 h. The yield of receptor was generally 85–95%. Investigations wi…
Isobaric Vapor–Liquid–Liquid Equilibria for the Ternary Systems Ethanol + Water + Propyl Acetate and 1-Propanol + Water + Propyl acetate
2014
In order to break azeotropes appearing in mixtures of water and either ethanol or 1-propanol, an azeotropic distillation process is proposed using propyl acetate as entrainer. Therefore, isobaric vapor–liquid–liquid equilibrium (VLLE) data at atmospheric pressure have been obtained for the ternary systems ethanol + water + propyl acetate and 1-propanol + water + propyl acetate. Data correlation has been carried out in four different ways and a comparison between the results obtained in each correlation has been done. The set of parameters obtained from the best correlation has been used in the VLLE estimation. Effects of using propyl acetate as entrainer in the azeotropic distillation have …