Search results for "Probe"
showing 10 items of 534 documents
Hydrophobic pocket targeting probes for enteroviruses
2015
Visualization and tracking of viruses without compromising their functionality is crucial in order to understand virus targeting to cells and tissues, and to understand the subsequent subcellular steps leading to virus uncoating and replication. Enteroviruses are important human pathogens causing a vast number of acute infections, and are also suggested to contribute to the development of chronic diseases like type I diabetes. Here, we demonstrate a novel method to target site-specifically the hydrophobic pocket of enteroviruses. A probe, a derivative of Pleconaril, was developed and conjugated to various labels that enabled the visualization of enteroviruses under light and electron micros…
Cryogenic 35GHz pulse ENDOR probehead accommodating large sample sizes: Performance and applications.
2009
The construction and performance of a cryogenic 35GHz pulse electron nuclear double resonance (ENDOR) probehead for large samples is presented. The resonator is based on a rectangular TE(102) cavity in which the radio frequency (rf) B(2)-field is generated by a two turn saddle ENDOR coil crossing the resonator along the sample axis with minimal distance to the sample tube. An rf power efficiency factor is used to define the B(2)-field strength per square-root of the transmitted rf power over the frequency range 2-180MHz. The distributions of the microwave B(1)- and E(1)-field, and the rf B(2)-field are investigated by electromagnetic field calculations. All dielectrics, the sample tube, and…
Design and Study of a Wide-Band Printed Circuit Board Near-Field Probe
2021
Magnetic near-field probes (NFP) represent a suitable tool to measure the magnetic field level from a small electromagnetic interference (EMI) source. This kind of antenna is useful as a magnetic field probe for pre-compliance EMC measurements or debugging tasks since the user can scan a printed circuit board (PCB) looking for locations with strong magnetic fields. When a strong H-field point is found, the designer should check the PCB layout and components placement in that area to detect if this could result in an EMI source. This contribution focuses on analyzing the performance of an easy to build and low-cost H-field NFP designed and manufactured using a standard PCB stack-up. Thereby,…
Evidence for a biogenic, microorganismal origin of rock varnish from the Gangdese Belt of Tibet
2010
In the present study we examined material from the Ashikule Basin of Tibet. Chemical analyses were performed by use of energy dispersive X-ray spectroscopy and electron probe microanalysis to clarify whether the varnish layers that had developed on the surface of the rhyolite are indeed composed of varnish bodies and silica glaze. Electron microscopic analyses revealed that the surface of the varnish is covered both by filamentous hyphae bacterial and cocci-shaped forms. Within the varnish mineral layer in those samples two forms of bacteria-like microorganisms exist; cocci as tightly packed bacterial aggregates [within varnish bodies], and bacillus-like microorganisms [within the varnish m…
Study and dating of medieval ceramic tiles by analysis of enamels with atomic absorption spectroscopy, X-ray fluorescence and electron probe microana…
2002
Abstract This paper reports an analytical study of enamel on fragments of medieval tiles using atomic spectroscopy techniques — AAS, XRF and SEM/EDX. The samples came from a hermitage in the region of Valencia (Spain) and have different motifs, mainly floral ones in a wide variety of colors. A study of the soluble salts in the biscuits and mortar was carried out using AAS to determine their present capacity to produce efflorescence and the type of efflorescence. XRF was used to identify the oxides responsible for the different colors and the pigments used over large areas of the tiles (white and green). SEM/EDX was used to characterize the white and green and smaller areas of other colors. …
Representative major element compositions of clinopyroxenes and phlogopites from ultrapotassic rocks from Nangqian basin (Eastern Tibet)
2020
Representative major element compositions (in wt%) of clinopyroxenes and phlogopites from Nangqian ultrapotassic rocks. In-situ major-element compositions of mineral phases were obtained using the JEOL JXA-8230 Electron Microprobe at ISTerre, University Grenoble Alpes. Analytical conditions were 15 kV accelerating voltage and 12 nA beam current. The ZAF procedure was applied to reduce the raw data. The microprobe was calibrated using natural and synthetic standards. An X-ray element map of a calcite-bearing aggregate was acquired using 15 kV accelerating voltage and 10 nA beam current.
Rat fetuin: distribution of protein and mRNA in embryonic and neonatal rat tissues
1998
Fetuin is a serum protein widely distributed in the animal kingdom and found in all mammalian species so far investigated. It is mainly a fetal protein, in the sense that the highest concentrations are found in serum and body fluids of embryos and fetuses. In order to elucidate possible biological functions of fetuin, we have studied its synthesis and distribution during the prenatal development of the rat with immunohistochemistry and in situ hybridization. We have isolated fetuin from rat serum and produced an antibody against this protein. In situ hybridization was performed using a 375-nucleotides-long digoxigenin-labeled riboprobe. Fetuin was unevenly distributed in all organ systems d…
Performance of the Shape of Partial Discharge Signal Wireless Probes
2013
This paper focuses on the evaluation of the performances of three different antenna sensors suitable of Partial Discharge (PD) measurements. Monopole, triangular and spherical antennas were simulated by means of the surface moment method. The transmitting system is modeled by a power electronic device with a fault current between two metal plate. The shape of the simulated transmitted and received signals have been compared to verify the sensor the provides the best fidelity among the three. The auto-correlation function and the Pearson correlation index are adopted here for the comparison. A discussion on the dynamic characteristic of the different antenna probes and their use in different…
Structure and composition heterogeneity of a FeAl alloy prepared by one-step synthesis and consolidation processing and their influence on grain size…
2006
Abstract This paper aims to characterize a bulk dense FeAl (47 at.%) alloy synthesized and consolidated by one-step current-activated pressure-assisted processing of nanocrystalline elemental powders. The end-product was analyzed using a combination of scanning (SEM) and transmission electron microscopies (TEM), electron back-scattering diffraction (EBSD) as well as electron probe microanalysis (EPMA). Special attention was paid to verify the grain size (32–89 nm) previously determined by X-ray diffraction peak profile analysis. It has been found that this material displays equiaxed grains (0.8–4 μm in size) and contains limited structural defects like subgrains and dislocations. The EPMA r…
Distribution of chlorpromazine in a simplified blood influenced by various drugs
1973
The binding of chlorpromazine to erythrocytes and to albumin as influenced by other drugs was studied in a simplified blood (31.5±0.3% bovine erythrocytes, 4 g-% bovine serum albumin in 0.02 M phosphate buffer solution containing 0.15 M NaCl). the total concentration of chlorpromazine in the simplified blood was 10−4 M, the concentration of the displacing drugs was 10−3 M. After an incubation period of 3 h at 22° C the chlorpromazine concentration was determined in the albumin solution after centrifugation of the blood at 3000×g and in the aqueous phase after ultracentrifugation at 150000×g. Under control conditions 68.1±0.9% of chlorpromazine was bound to the erythrocytes, 28.5±0.9% was bo…