6533b7ddfe1ef96bd12753a5

RESEARCH PRODUCT

Performance of the Shape of Partial Discharge Signal Wireless Probes

Alfredo ContinFabio ViolaRosario MiceliPietro Romano

subject

EngineeringSignal processingsignal classificationDirectional antennaantenna probesbusiness.industryPartial Discharges; antenna probes; Signal Processing; diagnosticsPartial DischargesSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettricidiagnostics.SignalPower (physics)Moment (mathematics)Settore ING-IND/31 - ElettrotecnicaPartial dischargeSignal ProcessingElectronic engineeringdiagnosticsProbe designWirelessantenna probeAntenna (radio)Partial DischargebusinessComputer Science::Information Theory

description

This paper focuses on the evaluation of the performances of three different antenna sensors suitable of Partial Discharge (PD) measurements. Monopole, triangular and spherical antennas were simulated by means of the surface moment method. The transmitting system is modeled by a power electronic device with a fault current between two metal plate. The shape of the simulated transmitted and received signals have been compared to verify the sensor the provides the best fidelity among the three. The auto-correlation function and the Pearson correlation index are adopted here for the comparison. A discussion on the dynamic characteristic of the different antenna probes and their use in different application is proposed.

10.1109/powereng.2013.6635891http://hdl.handle.net/10447/73003