Search results for "Procedures"
showing 10 items of 1678 documents
Analytical Techniques for Furosemide Determination
2006
Abstract Due to the clinical importance of furosemide, a large number of analytical procedures to detect the presence of this drug in pharmaceutical and physiological samples has been developed. In this manuscript, a review of the most frequent analytical techniques described to determine furosemide is presented. Special attention has been paid to spectrophotometric and chromatographic techniques, but also to relevant methods using capillary electrophoresis or flow‐injection analysis, as well as the detection modes coupled to these techniques. The review also focuses on the different degradation pathways of the drug and cautions to prevent it, otherwise rarely or confusedly mentioned in the…
Procedures of Separation and Pre‐concentration for Molybdenum Determination Using Atomic Spectrometry—a Review
2004
Abstract The literature concerning the improvement of atomic and ionic procedures for molybdenum determination through separation and pre‐concentration were updated. Analytical procedures based on flame atomic absorption spectrometry (AAAS), electrothermal or graphite furnace atomic absorption spectrometry (GFAAS), inductively coupled plasma optical emission spectrometry (ICP‐OES), and inductively coupled plasma mass spectrometry were reviewed taking into consideration the preliminary steps, which can enhance the selectivity and sensitivity based on co‐precipitation, solvent extraction, and solid‐phase extraction. Both in‐batch and on‐line procedures were considered.
Photochemical derivatization and fluorimetric determination of reserpine in a flow-injection assembly
1991
Abstract The fluorimetric flow-injection determination of reserpine was achieved with the drug being derivatized on-line by photoreaction. PTFE tubing was helically coiled around a germicide lamp located between the injection valve and detector. Two analytical procedures are proposed using either dilute acetic acid or pure methanol as the carrier stream. The influence of foreign compounds was studied and the method was applied to the determination of reserpine in pharmaceutical formulations.
Recent trends in liquid chromatography-tandem mass spectrometry to determine pesticides and their metabolites in food
2007
Abstract The applications of liquid chromatography-mass spectrometry (LC-MS) have exploded in innumerable analytical fields, including pesticide-residue determination. There is no doubt that LC-MS is currently competing with gas chromatography (GC)-MS for the status of ‘reference’ analytical technique to determine pesticide residues and that its ever-increasing application is bound to the evolution of modern instruments and their growing performance qualities. We highlight the large number and variety of pesticides that can be readily determined using such instruments, the respective merits of the different mass analyzers, and the improvements brought about by tandem MS (MS 2 ). We also dis…
Protocol to compare column performance applied to hydrophilic interaction liquid chromatography
2019
Abstract The lack of retention of highly polar solutes in liquid chromatography with reversed phase columns (RPLC) can be solved through the use of the hydrophilic interaction liquid chromatographic (HILIC) mode. Due to the complexity of the separation mechanisms in HILIC and the different factors that may have significant influence, the selection of the appropriate stationary phase plays a fundamental role in the development of analytical procedures to obtain good performance. In this work, the chromatographic performance of bare silica and six polar stationary phases with different functionalized groups (with neutral, cationic, anionic and zwitterionic character) are investigated. The beh…
Noninvasive evaluation of the celiac trunk and superior mesenteric artery with multislice CT in patients with chronic mesenteric ischaemia.
2008
This study sought to assess the role of multislice computed tomography (MSCT) in patients with suspected chronic mesenteric ischaemia (CMI). Forty-five patients (29 men; mean age 68) underwent MSCT angiography of the abdomen for suspected CMI (main clinical finding: postprandial abdominal pain). The scan protocol was detectors/collimation 16/0.75 mm; feed 36 mm/s; rotation time 500 ms; increment 0.4 mm; 120-150 mAs and 120 kVp. A volume of 80 ml of contrast material was administered through an antecubital vein (rate 4 ml/s), followed by 40 ml of saline (rate 4 ml/s). Images were analysed on the workstation with different algorithms (axial image scrolling, multiplanar reconstructions, maximu…
Ascorbic acid content and transcriptional profiling of genes involved in its metabolism during development of petals, leaves, and fruits of orange (C…
2021
Citrus fruit is one of the most important contributors to the ascorbic acid (AsA) intake in humans. Here, we report a comparative analysis of AsA content and transcriptional changes of genes related to its metabolism during development of petals, leaves and fruits of Valencia Late oranges (Citrus sinensis). Petals of close flowers and at anthesis contained the highest concentration of AsA. In fruits, AsA content in the flavedo reached a maximum at color break, whereas the pulp accumulated lower levels and experienced minor fluctuations during development. AsA levels in leaves were similar to those in the flavedo at breaker stage. The transcriptional profiling of AsA biosynthetic, degradatio…
Intraoperative transfusion practices and perioperative outcome in the European elderly: A secondary analysis of the observational ETPOS study
2022
PLOS ONE 17(1), e0262110 (2022). doi:10.1371/journal.pone.0262110
The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…
2012
The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…
The prognostic value of skeletal muscle index on clinical and survival outcomes after cytoreduction and HIPEC for peritoneal metastases from colorect…
2021
BACKGROUND Cytoreductive surgery (CRS) and hypertermic intraperitoneal chemotherapy (HIPEC) represent the most effective strategy to manage peritoneal metastases (PM). This systematic review and meta-analysis aimed to assess the impact of body composition on clinical outcomes in patients with PM. METHODS A systematic literature search was performed using Medline, Web of Science and EMBASE databases from inception to the 20st August 2020. Data were independently extracted by 3 authors. Newcastle-Ottawa Scale was used to assess quality and risk of bias of studies. Pooled analyses were performed using Mantel-Haenszel method to estimate overall effect size with mean differences or odd ratios (O…