Search results for "Process"
showing 10 items of 22310 documents
Automatic Detection of Left Ventricular Contours from Cardiac Cine Magnetic Resonance Imaging Using Fuzzy Logic
1999
Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method.The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejecti…
Ventricular Tachycardia and Early Fibrillation in Patients With Brugada Syndrome and Ischemic Cardiomyopathy Show Predictable Frequency-Phase Propert…
2015
[EN] Background¿ Ventricular fibrillation (VF) has been proposed to be maintained by localized high-frequency sources. We tested whether spectral-phase analysis of the precordial ECG enabled identification of periodic activation patterns generated by such sources. Methods and Results¿Precordial ECGs were recorded from 15 ischemic cardiomyopathy and 15 Brugada syndrome (type 1 ECG) patients during induced VF and analyzed in the frequency-phase domain. Despite temporal variability, induced VF episodes lasting 19.6±7.9 s displayed distinctly high power at a common frequency (shared frequency, 5.7±1.1 Hz) in all leads about half of the time. In patients with Brugada syndrome, phase analysis of …
Automatic determination of aortic compliance with cine-magnetic resonance imaging - An application of fuzzy logic theory
2002
International audience; Abstract: RATIONALE AND OBJECTIVES. Aortic compliance is defined as the relative change in aortic cross-sectional area divided by the change in arterial pressure. Magnetic resonance imaging (MRI) is a useful imaging modality for the noninvasive evaluation of aortic compliance. However, manual tracing of the aortic contour is subject to important interobserver variations. To estimate the aortic compliance from cine-MRI, a method based on fuzzy logic theory was elaborated. MATERIALS AND METHODS. Seven healthy volunteers and eight patients with Marfan syndrome were examined using an ECG gated cine-MRI sequence. The aorta was imaged in the transverse plane at the level o…
Olfactory Event-Related Potentials Reflect Individual Differences in Odor Valence Perception
2006
Investigating the neural substrates of perceived quality in olfaction using different odorants is intrinsically difficult. By utilizing individual differences in perceived quality of the odor of androstenone, we obtained a continuum of individual differences in rated valence of the same stimulus allowing investigations of its manifestation in the olfactory event-related potentials (ERPs). In an initial group consisting of 43 individuals that were screened for their verbal descriptors and sensitivity for the odor of androstenone, 22 normosmic volunteers were chosen forming 2 distinct groups with regard to verbal labels (‘‘body odor'' and ‘‘nonbody odor'') for androstenone while maintaining c…
Effects of panel experience on olfactory memory performance: influence of stimuly familiarity and labeling ability of subjects
1996
This work attempted to define the impact of panel experience on olfactory memory performance by comparing scores in an odor recognition task obtained from a highly trained descriptive panel (17 subjects) and a naive one (33 subjects with no experience in sensory analysis). During the inspection phase, 16 odorants were presented monadically to subjects for familiarity rating and a written description. The recognition session was planned 7 days later with 32 odorants (including the 16 of the target set). Subjects also described the odor of the stimuli. The memory performance of each panel was estimated by the mean value of individual d' (index of detectability). Training of the descriptive pa…
A fully automated system for the evaluation of masseter silent periods.
1997
Exteroceptive suppression of masseter muscle activity, 'masseter inhibitory reflex', comprises one or 2 silent periods (SP1 and SP2) interrupting the voluntary activation. The main problem when evaluating exteroceptive suppression is the lack of an objective and precise measure for the onset and end of the silent period which so far has not been overcome by various automated systems. We describe a new fully automated system for determining the onset and end of the masseter silent period. The decision approach is essentially based upon deterministic properties of median filters which are used to partition the local variances of the EMG traces into constant segments and edges between them. Th…
Prevalence and pattern of cognitive impairment in systemic lupus erythematosus patients with and without overt neuropsychiatric manifestations
2001
The prevalence and pattern of cognitive impairment in systemic lupus erythematosus (SLE) patients with (NPSLE) and without (nSLE) overt neuropsychiatric manifestations were investigated. Fifty-two nSLE patients, 23 NPSLE patients and 27 healthy controls were evaluated with a battery of standardized neuropsychological and psychological tests. Disease duration, disease activity index, and current corticosteroid therapy were collected. Cognitive impairment was identified in 14 (26.9%) and in 12 (52.2%) of subjects with nSLE and NPSLE, respectively. Both SLE groups showed a significant impairment compared with controls on tasks assessing verbal and non-verbal long-term memory, and visuoconstruc…
The internal calcar septum and its contact with the virtual stem in THR: a computer tomographic evaluation.
2003
The internal calcar septum is a ridge of cortical bone protruding from the inner cortical wall of the proximal femur into the medullary canal. It extends from the lesser trochanter into the femoral neck and narrows the femoral cavity in its dorsal third. This region is essential for THR stability, but the degree of contact between the septum and standard THR implants has never been studied. We obtained CT scans of 50 arthrotic hip joints from patients requiring THR. Virtual stems (50 straight/wedge-shaped and 50 anatomic stems) were placed in CT images of the femora using a PC-based preoperative planning unit. The dimensions of the septum, degree and location of contact between the septum a…
Hepatic Hilar and Sectorial Vascular and Biliary Anatomy in Right Graft Adult Live Liver Donor Transplantation
2008
Abstract Introduction The aim of this study was to analyze vascular and biliary variants at the hilar and sectorial level in right graft adult living donor liver transplantation. Methods From January 2003 to June 2007, 139 consecutive live liver donors underwent three-dimensional computed tomography (3-D CT) reconstructions and virtual 3-D liver partitioning. We evaluated the portal (PV), arterial (HA), and biliary (BD) anatomy. Results The hilar and sectorial biliary/vascular anatomy was predominantly normal (70%–85% and 67%–78%, respectively). BD and HA showed an equal incidence (30%) of hilar anomalies. BD and PV had a nearly identical incidence of sectorial abnormalities (64.7% and 66.2…
Macular edema computer-aided evaluation in ocular vein occlusions.
1998
This paper is concerned with the use of digital fundus imaging to detect, quantify, and follow up macular angiographic leakage due to retinal vein occlusions. Images were matched automatically. We detected those pixels with a high increment in gray level within the closest area to the foveal center. Binary images displaying leakage were obtained. The procedure was checked against two observers' agreement. Twenty-one angiographic studies were collected. Two images of each sequence were selected for digitalization. Numerical descriptors of the leakage were proposed and quantification plots were designed for each pair of images. Interobserver concordance ranged between 82 and 98% when manually…