Search results for "Profilometer"

showing 10 items of 12 documents

X-ray microtomography and laser ablation in the analysis of ink distribution in coated paper

2015

A novel method was developed for studying the ink-paper interface and the structural variations of a deposited layer of ink. Combining high-resolution x-ray tomography with laser ablation, the depth profile of ink (toner), i.e., its varying thickness, could be determined in a paper substrate. X-ray tomography was used to produce the 3D structure of paper with about 1 μm spatial resolution. Laser ablation combined with optical imaging was used to produce the 3D structure of the printed layer of ink on top of that paper with about 70 nm depth resolution. Ablation depth was calibrated with an optical profilometer. It can be concluded that a toner layer on a light-weight-coated paper substrate …

TopographyCoated paperLaser ablationX-ray microtomographyMaterials scienceta114Inkwellbusiness.industrymedicine.medical_treatmentGeneral Physics and AstronomySurface structureLaserAblationLaser ablationImage analysislaw.inventionOpticslawmedicineProfilometerta216businessTomographyImage resolutionJournal of Applied Physics
researchProduct

Speckle correlation technique to determine roughness in the dermatologic interval.

1988

A non-invasive method is proposed to determine human skin roughness. The technique is based on measurement of the correlation between two field distributions scattered by a metallised triafol (cellulose acetate foil) replica of the epidermal area to be analysed. The two speckle patterns are produced from the same rough surface illuminated by two coherent plane waves (He-Ne laser) under two slightly different angles. The accuracy of the method is highlighted by measurements made on a set of standard samples with roughnesses previously determined by mechanical profilometry. Analysis of the results indicates a precision of around 10%, and an applicability within the interest range of very roug…

Materials scienceRadiological and Ultrasound TechnologyField (physics)business.industrySurface PropertiesPlane waveSurface finishLaserlaw.inventionSpeckle patternOpticslawPhotogrammetryRange (statistics)HumansRadiology Nuclear Medicine and imagingProfilometerbusinessFOIL methodSkinPhysics in medicine and biology
researchProduct

Testing the use of an image-based technique to measure gully erosion at Sparacia experimental area

2016

The first part of this investigation was aimed at testing the use of a three-dimensional (3D) Digital Terrain Model (DTM) and a quasi-tridimensional (2.5D) Digital Elevation Model (DEM) obtained by a large series of oblique images of eroded channels taken from consumer un-calibrated and non-metric cameras. For two closed earth channels having a different sinuosity the ground measurement of some cross-sections by a profilometer (P) was carried out. The real volume of each channel was also measured by waterproofing it by a plastic film and filling it with a known volume of water. The comparison among the three methods (3D, 2.5D and P) pointed out that a limited underestimation of the total vo…

010504 meteorology & atmospheric sciencesSoil scienceChannelized04 agricultural and veterinary sciencesSinuosity01 natural sciencesVolume (thermodynamics)040103 agronomy & agricultureErosion0401 agriculture forestry and fisheriesProfilometerEmpirical relationshipDigital elevation modelGeology0105 earth and related environmental sciencesWater Science and TechnologyRemote sensingCommunication channelHydrological Processes
researchProduct

Measuring rill erosion using structure from motion: A plot experiment

2017

Abstract In this paper the results of a plot experiment on rill erosion are reported. The rill network, manually incised on the soil and further shaped by a clear inflow discharge, was surveyed using the three-dimensional photo-reconstruction (3D-PR) technique which allows to obtain a digital terrain model (DTM) by a large series of oblique images of the channel from consumer un-calibrated and non-metric cameras. The three-dimensional (3D) DTM and the quasi-tridimensional (2.5D) model were generated by Agisoft Photoscan software. For a single rill channel, the reliability of the 3D image-based ground measurements of morphological and hydraulic variables was positively tested by the correspo…

010504 meteorology & atmospheric sciences0208 environmental biotechnologyFlow (psychology)02 engineering and technologyInflow01 natural sciencesSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliDigital elevation modelGeomorphology0105 earth and related environmental sciencesEarth-Surface ProcessesRill erosiongeographygeography.geographical_feature_categoryRill characteristicDEMSedimentChannelizedField experiment020801 environmental engineeringRillErosion3D Photo-reconstructionImage-based ground measurement techniqueProfilometerGeologyCATENA
researchProduct

The experimental setup of the Interaction in Crystals for Emission of RADiation collaboration at Mainzer Mikrotron: Design, commissioning, and tests

2015

Silicon/germanium flat/bent crystals are thin devices able to efficiently deflect charged particle GeV-energy beams up to a few hundreds of μrad; moreover, high intensity photons can be efficiently produced in the so-called Multi-Volume Reflection (MVR) and Multiple Volume Reflections in One Crystal (MVROC) conditions. In the last years, the research interest in this field has moved to the dynamic studies of light negative leptons in the low energy range: the possibility to deflect negative particles and to produce high intensity γ sources via the coherent interactions with crystals in the sub-GeV energy range has been proved by the ICE-RAD (Interaction in Crystals for Emission of RADiation…

PhotonPhysics::Instrumentation and DetectorsCrystals characterizationsBENT CRYSTALSCoherent interaction; Crystals characterizations; High intensity gamma sources;ScintillatorCoherent interactionVOLUME REFLECTION; CHARGED-PARTICLES; BENT CRYSTALS; SILICON; MICROTRONNOOpticsSILICONInstrumentationPhysicsRange (particle radiation)High intensity gamma sourcesbusiness.industryVOLUME REFLECTIONCharged particleCHARGED-PARTICLESBeamlineGoniometerMICROTRONScintillation counterPhysics::Accelerator PhysicsProfilometerbusiness
researchProduct

Effect of three prophylaxis methods on surface roughness of giomer

2010

Objectives: Plaque and stains are removed by prophylaxis methods from tooth surfaces. Since prophylaxis methods can have a detrimental effect on the surface finish of restorations, the aim of this in vitro study was to investigate the effect of three prophylaxis methods, including pumice with rubber cup, pumice with brush, and air-powder polishing device (APD) on the surface roughness of giomer. Study design: Sixty four cylindrical giomer (Beautifil II, Shofu) samples with a diameter of 6 mm and a height of 2 mm were used. Subsequent to a 3-month period of storage in distilled water at 37ºC, the samples were randomly divided into four groups of 16. In group 1 (control), no prophylaxis proce…

Rubber CupMaterials scienceAtomic force microscopybusiness.industrySurface PropertiesAcrylic ResinsBrushDentistryDental ProphylaxisSurface finishSilicon Dioxide:CIENCIAS MÉDICAS [UNESCO]law.inventionOtorhinolaryngologylawPumiceUNESCO::CIENCIAS MÉDICASSurface roughnessIn vitro studySurgeryProfilometerbusinessGeneral Dentistry
researchProduct

Wear rates and wear mechanisms of alumina-based tools cutting steel at a low cutting speed

1997

Abstract Three ceramic insert materials, zirconia-toughened alumina (Al 2 O 3 –7vol%ZrO 2 ), mixed-based alumina (Al 2 O 3 –TiN–TiC–ZrO 2 ) and alumina reinforced with SiC whiskers (Al 2 O 3 –SiC w ), were used to cut AISI 1040 steel at 3.9 m s −1 . In addition, a traditional grade P10 insert (WC–TiC–Co) was tested. The lifetimes, according to KT/KM and VB B criteria, were determined using a profilometer and by image processing. The worn zones were observed with scanning electron microscopy techniques. Adhesion and plastic deformation were dominant wear mechanisms in zirconia-toughened alumina, mixed-based alumina and sintered carbide P10, both in the craters and in the cutting edges. As we…

Insert (composites)Materials scienceScanning electron microscopeWhiskersSurfaces and InterfacesAdhesionCondensed Matter PhysicsSurfaces Coatings and FilmsCarbideMechanics of Materialsvisual_artMaterials Chemistryvisual_art.visual_art_mediumCeramicProfilometerComposite materialWear
researchProduct

Computer vision profilometer: equipment and evaluation of measurements

1991

Abstract This paper describes a new equipment that measures roughness values by a computer vision (CV) technique. Measurements carried out by a CV profilometer are also evaluated. A laser source (power 2 mW), a cylindrical lens and a charge coupled device (CCD) TV-camera with a suitable optical system form an image of the profile of the sample under inspection. This image is then transformed into a binary image by thresholding and the line that divides the bright zone from the dark zone is the sample profile. From this line the characteristic roughness values can be calculated. The roughness measurements are carried out both by the CV profilometer and a stylus profilometer on eight specimen…

Materials sciencebusiness.industryBinary imageSurfaces and InterfacesSurface finishCondensed Matter PhysicsSample (graphics)ThresholdingSurfaces Coatings and FilmsOpticsMechanics of MaterialsMaterials ChemistryComputer visionCharge-coupled deviceProfilometerCylindrical lensArtificial intelligencebusinessStylusWear
researchProduct

Applicability of a binary amplitude mask for creating correctors of higher-order ocular aberrations in a photoresistive layer

2012

Ocular aberrations can be corrected with wavefront correctors created in a photoresist layer. The simplest type of the mask used in optical lithography is a binary amplitude mask. It is known that such a mask has a periodic hole pattern. The purpose of this research was to assess applicability of a binary amplitude mask for creating ocular wavefront correctors. The photoresist was applied to the substrate by using the dip-coating method. The photoresist layer was illuminated through a mask printed on a transparent film by using a laser printer. The surface of the wavefront correctors was evaluated by aberrometry, scanning electron microscopy and profilometry method. The dip-coating method c…

WavefrontMaterials sciencebusiness.industryGeneral EngineeringPhotoresistAtomic and Molecular Physics and OpticsLight scatteringlaw.inventionOpticslawProfilometerSpatial frequencyPhotolithographyPhotomaskAdaptive opticsbusinessOptical Engineering
researchProduct

Effect of mouthwashes on the integrity of composite resin and resin modified glass ionomer : in vitro study

2018

Background The constant search for an improved esthetic dental material has led investigators to realize that its performance depends on the conditions where the material is used. It has been probed that the contact with mouth rinses triggers alterations, reason why the aim of this study was to identify their possible effects of it on the integrity of nanohybrid composite resin and resin modified glass ionomer. Material and methods A total of 144 samples were manufactured with two nanohybrid composite resins and two resin modified glass ionomer restorative materials. The specimens were immersed in one of the three mouthwashes used in the study, for a total of 1092 minutes, with intervals of…

Materials scienceResearchComposite numberGlass ionomer cementResin modified030206 dentistry02 engineering and technologySurface finish021001 nanoscience & nanotechnology:CIENCIAS MÉDICAS [UNESCO]03 medical and health sciences0302 clinical medicinestomatognathic systemMouth rinseBiomaterials and Bioengineering in DentistryUNESCO::CIENCIAS MÉDICASSurface roughnessIn vitro studyProfilometerComposite material0210 nano-technologyGeneral Dentistry
researchProduct