Search results for "Profilometer"
showing 10 items of 12 documents
Measuring rill erosion using structure from motion: A plot experiment
2017
Abstract In this paper the results of a plot experiment on rill erosion are reported. The rill network, manually incised on the soil and further shaped by a clear inflow discharge, was surveyed using the three-dimensional photo-reconstruction (3D-PR) technique which allows to obtain a digital terrain model (DTM) by a large series of oblique images of the channel from consumer un-calibrated and non-metric cameras. The three-dimensional (3D) DTM and the quasi-tridimensional (2.5D) model were generated by Agisoft Photoscan software. For a single rill channel, the reliability of the 3D image-based ground measurements of morphological and hydraulic variables was positively tested by the correspo…
Testing the use of an image-based technique to measure gully erosion at Sparacia experimental area
2016
The first part of this investigation was aimed at testing the use of a three-dimensional (3D) Digital Terrain Model (DTM) and a quasi-tridimensional (2.5D) Digital Elevation Model (DEM) obtained by a large series of oblique images of eroded channels taken from consumer un-calibrated and non-metric cameras. For two closed earth channels having a different sinuosity the ground measurement of some cross-sections by a profilometer (P) was carried out. The real volume of each channel was also measured by waterproofing it by a plastic film and filling it with a known volume of water. The comparison among the three methods (3D, 2.5D and P) pointed out that a limited underestimation of the total vo…
Wear rates and wear mechanisms of alumina-based tools cutting steel at a low cutting speed
1997
Abstract Three ceramic insert materials, zirconia-toughened alumina (Al 2 O 3 –7vol%ZrO 2 ), mixed-based alumina (Al 2 O 3 –TiN–TiC–ZrO 2 ) and alumina reinforced with SiC whiskers (Al 2 O 3 –SiC w ), were used to cut AISI 1040 steel at 3.9 m s −1 . In addition, a traditional grade P10 insert (WC–TiC–Co) was tested. The lifetimes, according to KT/KM and VB B criteria, were determined using a profilometer and by image processing. The worn zones were observed with scanning electron microscopy techniques. Adhesion and plastic deformation were dominant wear mechanisms in zirconia-toughened alumina, mixed-based alumina and sintered carbide P10, both in the craters and in the cutting edges. As we…
Effect of professional dental prophylaxis on the surface gloss and roughness of CAD/CAM restorative materials
2017
Background This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). Material and methods After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for …
Effect of finishing and polishing systems on the surface roughness and color change of composite resins
2020
Background This study is to examine the surface roughness and color changes occurring on composite resins following the application of different finishing and polishing systems. Material and Methods In our study, a total of 200 samples were prepared from composites resin (6×2 mm) containing supra-nano, submicron hybrid, nanohybrid, nano-ceramic and microhybrid filler. They were polished with diamond, aluminum oxide, silicon carbide finishing and polishing systems. The initial color values of composite samples were measured with a spectrophotometer and surface roughness values with a profilometer. After that, samples were immersed of coffee solution and color measurements were repeated on th…
Speckle correlation technique to determine roughness in the dermatologic interval.
1988
A non-invasive method is proposed to determine human skin roughness. The technique is based on measurement of the correlation between two field distributions scattered by a metallised triafol (cellulose acetate foil) replica of the epidermal area to be analysed. The two speckle patterns are produced from the same rough surface illuminated by two coherent plane waves (He-Ne laser) under two slightly different angles. The accuracy of the method is highlighted by measurements made on a set of standard samples with roughnesses previously determined by mechanical profilometry. Analysis of the results indicates a precision of around 10%, and an applicability within the interest range of very roug…
Effect of mouthwashes on the integrity of composite resin and resin modified glass ionomer : in vitro study
2018
Background The constant search for an improved esthetic dental material has led investigators to realize that its performance depends on the conditions where the material is used. It has been probed that the contact with mouth rinses triggers alterations, reason why the aim of this study was to identify their possible effects of it on the integrity of nanohybrid composite resin and resin modified glass ionomer. Material and methods A total of 144 samples were manufactured with two nanohybrid composite resins and two resin modified glass ionomer restorative materials. The specimens were immersed in one of the three mouthwashes used in the study, for a total of 1092 minutes, with intervals of…
Computer vision profilometer: equipment and evaluation of measurements
1991
Abstract This paper describes a new equipment that measures roughness values by a computer vision (CV) technique. Measurements carried out by a CV profilometer are also evaluated. A laser source (power 2 mW), a cylindrical lens and a charge coupled device (CCD) TV-camera with a suitable optical system form an image of the profile of the sample under inspection. This image is then transformed into a binary image by thresholding and the line that divides the bright zone from the dark zone is the sample profile. From this line the characteristic roughness values can be calculated. The roughness measurements are carried out both by the CV profilometer and a stylus profilometer on eight specimen…
The experimental setup of the Interaction in Crystals for Emission of RADiation collaboration at Mainzer Mikrotron: Design, commissioning, and tests
2015
Silicon/germanium flat/bent crystals are thin devices able to efficiently deflect charged particle GeV-energy beams up to a few hundreds of μrad; moreover, high intensity photons can be efficiently produced in the so-called Multi-Volume Reflection (MVR) and Multiple Volume Reflections in One Crystal (MVROC) conditions. In the last years, the research interest in this field has moved to the dynamic studies of light negative leptons in the low energy range: the possibility to deflect negative particles and to produce high intensity γ sources via the coherent interactions with crystals in the sub-GeV energy range has been proved by the ICE-RAD (Interaction in Crystals for Emission of RADiation…
Effect of three prophylaxis methods on surface roughness of giomer
2010
Objectives: Plaque and stains are removed by prophylaxis methods from tooth surfaces. Since prophylaxis methods can have a detrimental effect on the surface finish of restorations, the aim of this in vitro study was to investigate the effect of three prophylaxis methods, including pumice with rubber cup, pumice with brush, and air-powder polishing device (APD) on the surface roughness of giomer. Study design: Sixty four cylindrical giomer (Beautifil II, Shofu) samples with a diameter of 6 mm and a height of 2 mm were used. Subsequent to a 3-month period of storage in distilled water at 37ºC, the samples were randomly divided into four groups of 16. In group 1 (control), no prophylaxis proce…