Changes in cerebral oxygen saturation following prone positioning for orthopaedic surgery under general anaesthesia: a prospective observational stud…
2015
Prone positioning is often necessary in orthopaedic surgery. The prone position, however, may result in impaired cerebral venous drainage with a subsequent reduction in cerebral perfusion. As a consequence, cerebral hypoxia may occur with the potential for neurological impairment.We assessed the changes in cerebral oxygen saturation with near-infrared spectroscopy using two different monitors after positioning the patient from supine to prone.Prospective observational study.Primary Care University Hospital, from May 2010 to February 2011.Forty patients undergoing general anaesthetic procedures, of which 35 completed the investigation. Similar measurements were done in 35 volunteers, who wer…
Colorectal Polyps: Detection with Dark-Lumen MR Colonography versus Conventional Colonoscopy
2005
To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps.Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T …
Neck semispinalis capitis muscle size in sitting and prone positions measured by real-time ultrasonography.
1998
Objective: To examine the reliability of measurements of semispinalis capitis muscle (SECM) cross-sectional area (CSA) in prone and sitting positions, and to compare the muscle size in these two positions. Design: Semispinalis capitis CSA was measured twice a day on two successive days with a real-time ultrasound apparatus. Subjects: Eighteen males (aged 19–34 years) and 28 females (aged 19–34 years) were studied for the reliability test. Seven males and 12 females were randomly selected to compare SECM size in sitting and prone positions. Results: The intraclass correlation coefficient (ICC) for repeatability measurements was r = 0.98 for the two positions. The correlation of the CSA in s…
Cerebral venous outflow in the prone position
2020
Analysis and modulation of the inflammatory response through lung agression related to bacterial infection and mechanical ventilation
2015
Despite major advances since decades in the management of ventilated patients, ventilator-associated pneumonia (VAP) continues to complicate the course of approximately 28% of the patients receiving mechanical ventilation (MV). Among patients hospitalized in intensive care units, the risk of pneumonia is 3- to 10- fold increased in MV patients. However, MV is often the only way to care for critically ill patients with respiratory failure. It has now been clearly demonstrated that MV, in particular adverse ventilatory strategies could activate lung cells, thus leading to a proinflammatory response, even in the absence of pathogen. This is the biotrauma paradigm, which accounts, at least in p…
Geo-economic variations in epidemiology, patterns of care, and outcomes in patients with acute respiratory distress syndrome: insights from the LUNG …
2017
Background Little information is available about the geo-economic variations in demographics, management, and outcomes of patients with acute respiratory distress syndrome (ARDS). We aimed to characterise the effect of these geo-economic variations in patients enrolled in the Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG SAFE). Methods LUNG SAFE was done during 4 consecutive weeks in winter, 2014, in a convenience sample of 459 intensive-care units in 50 countries across six continents. Inclusion criteria were admission to a participating intensive-care unit (including transfers) within the enrolment window and receipt of invasive or non…
Effect of Prolonged Military Field Training on Neuromuscular and Hormonal Responses and Shooting Performance in Warfighters
2018
Introduction: Previous studies have shown that military field training (MFT) has effects on warfighters’ hormonal responses, neuromuscular performance, and shooting accuracy. The aim of the present study was to investigate the changes in body composition, upper and lower body strength, serum hormone concentrations of testosterone (TES) and cortisol (COR), insulin-like growth factor-1 (IGF-1), and sex hormone binding globulin (SHBG) and shooting accuracy during prolonged MFT. Methods: Serum hormone concentrations, isometric strength of the upper and lower extremities, and shooting performance were measured four times during the study: before MFT (PRE), after 12 d (MID), at the end of MFT (PO…
Patient centring and scan length: how inaccurate practice impacts on radiation dose in CT colonography (CTC).
2019
Objective: The aim of this study was to acknowledge errors in patients positioning in CT colonography (CTC) and their effect in radiation exposure. Materials and methods: CTC studies of a total of 199 patients coming from two different referral hospitals were retrospectively reviewed. Two parameters have been considered for the analysis: patient position in relation to gantry isocentre and scan length related to the area of interest. CTDI vol and DLP were extracted for each patient. In order to evaluate the estimated effective total dose and the dose to various organs, we used the CT-EXPO ® software version 2.2. This software provides estimates of effective dose and doses to the other vario…
The effect of body posture on long range time-to-contact estimation
2011
On Earth, gravity accelerates freely moving objects downward, whereas upward-moving objects are being decelerated. Do humans take internalised knowledge of gravity into account when estimating time-to-contact (TTC, the time remaining before the moving object reaches the observer)? To answer this question, we created a motion-prediction task in which participants saw the initial part of an object's trajectory moving on a collision course prior to an occlusion. Observers had to judge when the object would make contact with them. The visual scene was presented with a head-mounted display. Participants lay either supine (looking up) or prone (looking down), suggestive of the ball either rising…
CT-guided nephrostomy–An expedient tool for complex clinical scenarios
2018
Abstract Introduction & objectives Percutaneous nephrostomy [ 1 ] has emerged as a pivotal approach in the therapeutic management of the obstructed urinary tract. A consecutive incorporation of ultrasonic and radiographic guidance, the approach experienced an almost ubiquitious distribution while most centers currently applying either one or both of these tools jointly. However, success of ultrasound-guidance is limited in obese patients and non-dilated uropathy. In turn, fluoroscopy usually requires an opacification of the urinary collecting system by intravenous or antegrade contrast media injection, which might be harmful for already impaired renal function, raise intrapelvic pressure an…