Search results for "Prostheses"

showing 10 items of 88 documents

New aspects in the histological examination of polyethylene wear particles in failed total joint replacements.

2002

The most important long-term complication in total joint replacements is aseptic osteolysis. Wear particles such as polyethylene (PE) debris are considered to be one of the causes that play a central role. Several studies indicated that PE can be visualised in paraffin-embedded tissue sections not only by polarised light, but also after oil red staining. To determine whether oil red staining enables sensitive detection of PE, we examined staining of mechanically-produced PE particles by oil red. Furthermore, we studied oil red staining of paraffin-embedded tissue specimens of patients with failed uncemented and cemented total knee and hip prostheses. We applied double labelling of sections …

MalePathologymedicine.medical_specialtyHistologyOsteolysisLightJoint ProsthesisTotal Joint ReplacementsAntigens Differentiation MyelomonocyticStainArthroplasty03 medical and health scienceschemistry.chemical_compound0302 clinical medicineAntigens CDMaterials TestingmedicineHumansColoring AgentsHistological examination030222 orthopedicsChemistryCell BiologyGeneral MedicineProstheses and ImplantsPolyethylenemedicine.diseaseImmunohistochemistry3. Good healthSurgeryStainingProsthesis FailureMicroscopy Electron030220 oncology & carcinogenesisImmunohistochemistryFemaleJointsAseptic processingPolyethylenesAzo CompoundsActa histochemica
researchProduct

Blood metal levels after minimally invasive repair of pectus excavatum

2021

Abstract   OBJECTIVES Minimally invasive repair of pectus excavatum (MIRPE) is the most popular surgical approach for paediatric patients with pectus excavatum. A substernal stainless still bar is inserted and left in place for 3 years and then removed. Our goal was to investigate blood metal levels after MIRPE and to correlate them with surgical details, such as the numbers of bars and stabilizers and the length of time the bar was in place. METHODS Blood levels of iron, chromium, manganese, molybdenum and nickel were analysed in 130 teenagers (108 boys and 22 girls) who had MIRPE using inductively coupled plasma mass spectrometry. A total of 62 patients were operated on using MIRPE (study…

MalePulmonary and Respiratory Medicinemedicine.medical_specialtyAdolescentThoracicMetallosiMIRPE03 medical and health sciences0302 clinical medicineStabilizer - ingredientPectus excavatummedicineHumansMinimally Invasive Surgical ProceduresMetallosisIn patientThoracoplasty030212 general & internal medicineChildMetal releasePectus excavatumRetrospective StudiesPaediatric patients030222 orthopedicsSurgical approachbusiness.industryProstheses and ImplantsPlastic Surgery Proceduresmedicine.diseaseSurgeryFunnel ChestMetal toxicityFemaleSurgeryImplantMetallic barCardiology and Cardiovascular Medicinebusiness
researchProduct

A New Prosthetic Implant for Inguinal Hernia Repair: Its Features in a Porcine Experimental Model

2011

Even after more than 100 years of inguinal hernia repair, the rate of complications and recurrence remains unacceptably high. In the last decades, few effective advances in surgical technique and materials have been made. The authors see them as minor adjustments in the shape and materials of the prosthetic implants. Still, the underlying genesis of inguinal hernia remains undefined. Based upon this, it seems the surgical repair of inguinal protrusions cannot be based upon the pathogenesis because the etiology to date has not been addressed. Most hernia repairs are performed with some degree of point fixation (sutures/tacks) to stop the mesh from migrating and creating high recurrence rates…

MaleSettore MED/18 - Chirurgia GeneraleTissue ScaffoldsHernia Inguinal Biocompatible materials Prostheses and implants Incorporation Guided tissue regeneration Tissue scaffoldingGuided Tissue RegenerationSwineAnimalsits features in a porcine experimental model [A new prosthetic implant for inguinal hernia repair]Hernia InguinalProstheses and ImplantsA new prosthetic implant for inguinal hernia repair: its features in a porcine experimental modelPolypropylenes
researchProduct

The role of antibiotic prophylaxis in reducing bacterial contamination of autologous bone graft collected from implant site

2017

The aim of this study was to evaluate if antibiotic prophylaxis reduces the bacterial contamination of bone particles collected directly from the burs used for implant site preparation. Thirty-four patients underwent the surgical procedures for a total of 34 implant sites. One 1 gr. tablet of amoxicillin + clavulanic acid was given to the test group 12 hours and 1 hour before the surgery. The control group did not take antibiotic prophylaxis. Bone particles were collected and centrifuged. The suspensions were subjected to serial dilutions and each dilution was examined twice using a spatulation technique in Trypticase Soy Agar (TSA), in Sabouraud Dextrose Agar, and in Mitis Salivarius Agar …

Malefood.ingredientArticle SubjectSerial dilutionmedicine.medical_treatmentlcsh:MedicineDentistryBone graftingTransplantation AutologousBone and BonesGeneral Biochemistry Genetics and Molecular Biology03 medical and health scienceschemistry.chemical_compound0302 clinical medicinefoodantibiotic prophylaxis bacterial contamination bone grafting bone particles dental implantsClavulanic acidmedicineHumansAgarTrypticase soy agarAntibiotic prophylaxisBone TransplantationBacteriaGeneral Immunology and Microbiologybusiness.industrylcsh:RProstheses and Implants030206 dentistryGeneral MedicineAntibiotic ProphylaxisMiddle AgedAmoxicillinAnti-Bacterial AgentsTransplantationchemistry030220 oncology & carcinogenesisClinical StudyFemalebusinessmedicine.drug
researchProduct

Series of fibrinous inflammation after implantation of capsular tension rings

2014

Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…

Malemedicine.medical_specialtyAfter cataractTopical treatmentMethylmethacrylatemedicine.disease_causeProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansUniversity medicalDevice RemovalAgedRetrospective StudiesAged 80 and overEndophthalmitisFibrinPhacoemulsificationAmoebocyte lysatebusiness.industrySmear testsFibrinous inflammationProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyMethacrylatesFemaleSurgeryIrritationbusinessJournal of Cataract and Refractive Surgery
researchProduct

Initial experience with the Sophono Alpha 1 osseointegrated implant.

2013

In the last several years, bone anchored hearing aids have proven to be useful in treating conductive and mixed unilateral or bilateral hearing loss, as well as for sensorineural unilateral hearing loss. The Sophono Alpha 1 model has the advantage of not requiring an abutment, with it being coupled by magnetism instead. We report the cases of 3 infants with congenital malformations of external and middle ear. Audiometry showed conductive hearing loss. All 3 patients were implanted with Alpha 1 model (Sophono). Patients evolved satisfactorily. After 30 days we applied the processor and the control audiometry showed a marked improvement of hearing thresholds, although without a complete closu…

Malemedicine.medical_specialtyHearing Loss ConductiveOsseointegrationHearing AidsOsseointegrationotorhinolaryngologic diseasesmedicineHumansAbnormalities MultipleChildmedicine.diagnostic_testbusiness.industryBone-anchored hearing aidEarGeneral MedicineProstheses and Implantsmedicine.diseaseConductive hearing lossSurgerymedicine.anatomical_structureMiddle earMagnetsFemaleImplantUnilateral hearing lossAudiometrybusinessAbutment (dentistry)Bone ConductionEar CanalActa otorrinolaringologica espanola
researchProduct

First Experiences With the Ponto⢢ SuperPower Osseointegrated Device

2018

Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto™ Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. Th…

Malemedicine.medical_specialtyHearing lossmedia_common.quotation_subjectSignal-To-Noise RatioAudiologybehavioral disciplines and activities01 natural sciences03 medical and health sciencesHearing Aids0302 clinical medicineBone conductionQuality of lifeOsseointegrationSurveys and QuestionnairesPerception0103 physical sciencesmedicineHumansProspective Studies030223 otorhinolaryngology010301 acousticsHearing Loss Mixed Conductive-Sensorineuralmedia_commonmedicine.diagnostic_testbusiness.industryAuditory ThresholdEquipment DesignProstheses and ImplantsGeneral MedicineMiddle Agedmedicine.diseaseConductive hearing lossTreatment OutcomePatient SatisfactionQuality of LifeFemaleObservational studymedicine.symptomAudiometrybusinessBone ConductionActa Otorrinolaringologica (English Edition)
researchProduct

Laparoscopic Repair of Boundary Incisional Hernia in a Kidney Transplant Patient: A Safe Tacks-Fibrin Glue Combined Mesh Fixation Technique.

2018

Abstract Background Incisional hernia in renal transplant patients is a complication that negatively affects the global outcome of transplant and quality of life. The repair of this condition was classically made by open repair with mesh. Increasing evidence suggests that laparoscopic repair could be advocated as the technique of choice in these patients with optimal results. However, the fixation of mesh should be performed by a mixed combination of fibrin sealant (lateral margin of wall defect) and tacks (medial margin). The tacks fixation of the mesh along the lateral margin of the wall defect, close to the graft, is generally difficult for the small size of the remaining aponeurotic pla…

Malemedicine.medical_specialtyIncisional hernialaparoscopic hernia repairPopulationpolypropylene-polyglycolic acid (PGA composite meshFibrin Tissue AdhesiveFibrinFixation (surgical)renal transplantmedicinelower lateral abdominal herniaHumansIncisional HerniaHerniaeducationFibrin glueKidney transplantationHerniorrhaphyAgedTransplantationeducation.field_of_studybiologybusiness.industryProstheses and ImplantsSurgical Meshmedicine.diseaseKidney TransplantationSurgeryfibrin gluesurgical procedures operativeSurgical meshbiology.proteinSurgeryFemaleLaparoscopyboundary herniabusinessTransplantation proceedings
researchProduct

Fixation free femoral hernia repair with a 3D dynamic responsive implant. A case series report

2018

Abstract Background To date, no gold standard for the surgical treatment of femoral hernia exists. Pure tissue repair as well as mesh/plug implantation, open or laparoscopic, are the most performed methods. Nevertheless, all these techniques need sutures or mesh fixation. This implies the risk of damaging sensitive structures of the femoral area, along with complications related to tissue tear and postoperative discomfort consequent to poor quality mesh incorporation. The present retrospective multicenter case series highlights the results of femoral hernia repair procedures performed with a 3D dynamic responsive implant in a cohort of 32 patients during a mean follow up of 27 months. Mater…

Malemedicine.medical_specialtyPostoperative discomfortProstheses and Implantmedicine.medical_treatmentProsthesis ImplantationChronic pain030230 surgery3D dynamic prosthesiProsthesisFollow-Up StudieProsthesis ImplantationAbdominal wall03 medical and health sciencesFixation (surgical)0302 clinical medicineRetrospective StudiemedicineHumansHerniaHerniorrhaphyHernia repair complicationRetrospective StudiesSurgical repairPain Postoperativebusiness.industryHernia repair fixation freeProbiotic biologic responseProstheses and ImplantsGeneral MedicineMiddle AgedFemoral herniamedicine.diseaseHernia FemoralSurgeryTreatment Outcomemedicine.anatomical_structure030220 oncology & carcinogenesisFemaleSurgeryImplantbusinessHumanFollow-Up StudiesInternational Journal of Surgery
researchProduct

Anterior cervical discectomy and fusion with ROI-C peek cage: cervical alignment and patient outcomes

2014

OBJECTIVE: The intersomatic cage ROI-C one is a new promising system in anterior cervical discectomy with subsequent fusion. METHODS: Patients were studied prospectively. ROI-C cages were used in consecutive 32 patients. Intraoperative parameters, clinical features and dysphagia scores were recorded. Radiographs evaluated the height of intervertebral space, the cervical Cobb angle and implant positioning. Data were collected on the last day of hospital stay, at 6 weeks, at 3, 6, 12 and 24 months. RESULTS: A total of 32 cages were implanted. One patient had transient dysphagia. The intervertebral height and the cervical Cobb angle were significantly improved at 24 months follow-up (P < 0.05)…

Malemedicine.medical_specialtyRadiographyAnterior cervical discectomy and fusionVertebral fusionmedicineHumanscervical discectomy fusion ACDFOrthopedics and Sports MedicineProspective StudiesProspective cohort studyAgedPain MeasurementNeck painNeck PainCobb anglebusiness.industrySettore MED/27 - NeurochirurgiaProstheses and ImplantsLength of StayMiddle AgedDysphagiaSurgerySpinal FusionTreatment OutcomeCervical VertebraeFemaleSurgeryImplantmedicine.symptomDeglutition DisordersbusinessDiskectomy
researchProduct