Search results for "Prosthesis Design"
showing 10 items of 245 documents
Fixed dental prostheses with vertical tooth preparations without finish lines: A report of two patients
2016
Tooth abutments can be prepared to receive fixed dental prostheses with different types of finish lines. The literature reports different complications arising from tooth preparation techniques, including gingival recession. Vertical preparation without a finish line is a technique whereby the abutments are prepared by introducing a diamond rotary instrument into the sulcus to eliminate the cementoenamel junction and to create a new prosthetic cementoenamel junction determined by the prosthetic margin. This article describes 2 patients whose dental abutments were prepared to receive ceramic restorations using vertical preparation without a finish line.
Design and validation of a neuroprosthesis for the treatment of upper limb tremor.
2013
Pathological tremor is the most prevalent movement disorder. In spite of the existence of various treatments for it, tremor poses a functional problem to a large proportion of patients. This paper presents the design and implementation of a novel neuroprosthesis for tremor management. The paper starts by reviewing a series of design criteria that were established after analyzing users needs and the expected functionality of the system. Then, it summarizes the design of the neuroprosthesis, which was built to meet the criteria defined previously. Experimental results with a representative group of 12 patients show that the neuroprosthesis provided significant (p <; 0.001) and systematic trem…
Maintenance of marginal bone support and soft tissue esthetics at immediately provisionalized OsseoSpeed implants placed into extraction sites: 2-yea…
2012
Background Placement of implants into extraction sockets targets the maintenance of peri-implant hard and soft tissue structures and the support of a natural and esthetic contour. The main advantages of immediate implant insertion in comparison with delayed implant placement protocols are as follows: a reduced treatment time, less number of sessions, and, thus, the less invasive procedure. This study examines the clinical performance (survival rate, marginal bone levels and Pink Esthetic Score [PES]) of OsseoSpeed™ implants placed into extraction sockets with immediate provisionalization in the anterior maxilla after a follow-up of at least 12 months. Methods Twenty patients received a tota…
Clinical and esthetic outcome with immediate insertion and provisionalization with or without connective tissue grafting in presence of mucogingival …
2017
Background Recessions following immediate implant insertion are frequently reported in the literature. Data regarding implant installation in presence of mucogingival recessions are rare. Purpose This study observes soft tissue level changes following immediate implant insertion and provisionalization of implants with or without connective tissue grafts in the anterior maxilla in patients with initial mucogingival recession within a follow-up period between one and eight years. Materials and methods Twenty-six patients with marginal gingival recessions, which were designated for extraction and immediate implant insertion in the anterior zone of the maxilla (13-23), were included. Out of a l…
Immediately provisionalized OsseoSpeed(™) Profile implants inserted into extraction sockets: 3-year results.
2015
Objectives A sloped shoulder might improve the congruence between extraction socket and dental implant and may add to a better circumferential support of the peri-implant structures. Therefore, this study evaluates the 3-year clinical outcome (survival and success rates, marginal bone levels, and Pink Esthetic Score (PES)) of immediately inserted and provisionalized OsseoSpeed(™) Profile implants in the anterior maxilla. Material and methods Twenty-one implants were inserted in 16 patients. All implants were immediately placed into extraction sites with and without facial bone deficiencies. A flapless procedure was utilized, and the implants were provisionalized immediately. Facial gaps wer…
Effect of implant macro-design on primary stability: A prospective clinical study
2016
Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…
Short-term Follow-up after Implantation of a Foldable Iris-Fixated Intraocular Lens in Phakic Eyes
2005
Objective To evaluate efficiency, predictability, stability, complications, and patient satisfaction after implantation of a foldable iris-fixated phakic intraocular lens (PIOL) for the correction of myopia. Design Prospective, nonrandomized, comparative (self-controlled) trial. Participants Forty-one eyes of 22 myopic patients aged 18 to 56 years (mean, 36 years) with average sphere of −8.2±2.01 diopters (D; range, −12.25 to −3.75 D) and average preoperative cylinder of −0.90±0.62 D (range, −2.50 to 0.00 D) were enrolled in this prospective study. Methods All eyes underwent implantation of a foldable iris-fixated PIOL with an optical zone of 6.0 mm. The follow-up was 6 months in all cases.…
Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible
2011
Objectives: Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. Material and Methods: A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data we…
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
2013
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Incidence of thromboembolic complications in patients with mechanical heart valves with a subtherapeutic international normalized ratio.
2008
Objective Subtherapeutic international normalized ratios are frequently encountered in clinical practice, and patients with mechanical heart valves with inadequate anticoagulation may be exposed to an increased risk of thromboembolic events. There are no data on thromboembolic event risk for these patients. Methods We assessed the current practice patterns in the management of patients with mechanical heart valves with subtherapeutic international normalized ratios and assessed the risk of thromboembolic complications in this setting. The charts of patients with mechanical heart valves followed up in two anticoagulation clinics were reviewed. Patients with a history of stable, therapeutic a…