Search results for "Prosthesis Design"

showing 10 items of 245 documents

Oval fiber posts do not improve adaptation to oval-shaped canal walls.

2011

Abstract Introduction Oval fiber posts attempt to provide better adaptation to root canals. The hypothesis of this study was that there are no differences in adaptation of oval and circular fiber posts to canal walls. Methods Posts were inserted in 20 canals; 10 were oval, and 10 were circular. The posts were cemented with composite cement. Coronal, middle, and apical sections were observed through a microscope. The space occupied by the post and the maximum distance between it and the canal wall were calculated. The 2 groups were compared with analysis of variance. In all the analyses the level of significance was set at P Results The proportion of space occupied by the post showed no sign…

Analysis of Variancedigestive oral and skin physiologyAnatomyDental Marginal Adaptationdigestive systemstomatognathic systemDental Prosthesis DesignHumansCanal wallBicuspidGlassDental Pulp CavityFiber postsGeneral DentistryCementationGeologyPost and Core TechniqueJournal of endodontics
researchProduct

A rare case of Prinzmetal angina 3 days after coronary artery stenting with a second-generation drug-eluting stent

2015

Non previsto.

Angina Pectoris VariantMaleCoronary angiographymedicine.medical_specialtyTime FactorsVasodilator Agentsmedicine.medical_treatmentCoronary VasospasmPrinzmetal angina coronary artery stenting stent second-generation drug-eluting stent.Coronary AngiographyProsthesis DesignBalloonAnginaAngioplastyInternal medicineRare caseHumansMedicineEverolimusAngioplasty Balloon CoronarySirolimusEverolimusbusiness.industryCoronary StenosisCardiovascular AgentsDrug-Eluting StentsGeneral MedicineMiddle Agedmedicine.diseaseSettore MED/11 - Malattie Dell'Apparato CardiovascolareTreatment Outcomemedicine.anatomical_structureDrug-eluting stentCardiologyPrinzmetal angina coronary artery stentingdrug-eluting stentCardiology and Cardiovascular Medicinebusinessmedicine.drugArteryCoronary Artery Disease
researchProduct

Accommodative intraocular lenses: current status

2005

Purpose of review The possibility of using a monofocal IOL with accommodative ability allows refractive cataract surgery with a clearly decreased potential of photic phenomena. Three IOLs of different designs and materials have demonstrated accommodative ability, but the degree of accommodative amplitude has been reported to different extents and variabilities. The plate-haptic CrystaLens has a hinged design that might permit forward movement of the optic as a result of pressure changes in the vitreous cavity. The 1CU has modified haptics that bend in the bag as the lens capsule contracts, which are supposed to cause anterior displacement of the lens optic. With the dual-optic one-piece Syn…

Anterior lensgenetic structuresmedicine.medical_treatmentCataract ExtractionProsthesis Designlaw.inventionLens Implantation IntraocularlawmedicineHumansLenses IntraocularLens capsulebusiness.industryAccommodation OcularPresbyopiaGeneral MedicinePresbyopiaCataract surgerymedicine.diseaseeye diseasesLens (optics)OphthalmologyIntraocular lensesCapsular bagOptometrysense organsbusinessAccommodationCurrent Opinion in Ophthalmology
researchProduct

Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse

2011

OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…

Aortic archMalemedicine.medical_specialtyAortographymedicine.medical_treatmentHemodynamicsAorta ThoracicFOS: Medical engineeringProsthesis DesignAortographyBlood Vessel Prosthesis ImplantationImaging Three-DimensionalBlood vessel prosthesismedicine.arteryMaterials TestingmedicineHumansComputer Simulationthoracic aortic stent graft (TASG)Aortamedicine.diagnostic_testbusiness.industryEndovascular ProceduresHemodynamicsModels CardiovascularStentSettore ING-IND/34 - Bioingegneria Industrialenutritional and metabolic diseases90399 Biomedical Engineering not elsewhere classifiedCurvatures of the stomachSurgeryBiomechanical PhenomenaBlood Vessel ProsthesisProsthesis FailureEquipment Failure AnalysisRegional Blood FlowRadiographic Image Interpretation Computer-AssistedStentslipids (amino acids peptides and proteins)SurgeryStress Mechanicalbiological phenomena cell phenomena and immunitybusinessNuclear medicineTomography X-Ray ComputedCardiology and Cardiovascular MedicinePerfusionAlgorithmsJournal of Vascular Surgery
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.

2016

OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …

Aortic valveMaleTime Factors030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolarelaw.inventionAortic aneurysm0302 clinical medicinelawAorta10042 Clinic for Diagnostic and Interventional RadiologyMedicine (all)Middle Aged2746 Surgerymedicine.anatomical_structureTreatment OutcomeWrapping girdlingFemaleCardiology and Cardiovascular MedicineVascular Surgical ProceduresPulmonary and Respiratory Medicinemedicine.medical_specialtyOffOff-pump610 Medicine & healthProsthesis Design2705 Cardiology and Cardiovascular MedicineGraft repair03 medical and health sciencesAneurysmBlood vessel prosthesismedicine.arteryAscending aortamedicineCardiopulmonary bypassHumansAortic valve insufficiency; Ascending aorta; Graft repair; Mesh (polypropylene/polyester); Off-pump; Wrapping girdling; Surgery; Medicine (all); Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular MedicineAgedRetrospective StudiesAortaAortic Aneurysm Thoracicbusiness.industryPerioperativemedicine.diseaseSternotomySurgeryBlood Vessel Prosthesis030228 respiratory systemAortic valve insufficiency2740 Pulmonary and Respiratory MedicinepumpSurgeryAscending aortaMesh (polypropylene/polyester)businessFollow-Up StudiesInteractive cardiovascular and thoracic surgery
researchProduct

Image quality with multifocal intraocular lenses and the effect of pupil size

2007

Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…

Artificial corneaOptics and PhotonicsImage qualitymedicine.medical_treatmentIntraocular lensProsthesis DesignModels BiologicalPupilContrast SensitivityOpticsOptical transfer functionmedicineHumansImaging scienceMathematicsLenses IntraocularFourier Analysisbusiness.industryPupil sizePupilMultifocal intraocular lensSensory SystemsOphthalmologyOptometrySurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Primary endpoint results of the OMEGA Study: One-year clinical outcomes after implantation of a novel platinum chromium bare metal stent.

2014

Bare metal stents (BMS) have similar rates of death and myocardial infarction (MI) compared to drug-eluting stents (DES). DES lower repeat revascularization rates compared to BMS, but may have higher rates of late stent thrombosis (ST) potentially due to impaired endothelialization requiring longer dual anti-platelet therapy (DAPT). OMEGA evaluated a novel BMS designed to have improved deliverability and radiopacity, in comparison to currently available platforms.OMEGA was a prospective, multicenter, single-arm study enrolling 328 patients at 37 sites (US and Europe). Patients received the OMEGA stent (bare platinum chromium element stent) for the treatment of de novo native coronary artery…

Bare-metal stentTarget lesionChromiumMalemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentRevascularizationCoronary AngiographyProsthesis DesignRisk AssessmentSeverity of Illness IndexCoronary artery diseaseCoronary RestenosisInternal medicineClinical endpointMedicineHumansSingle-Blind MethodMyocardial infarctionProspective StudiesAngioplasty Balloon CoronaryAgedPlatinumAged 80 and overbusiness.industryCoronary StenosisStentGeneral MedicineMiddle Agedmedicine.diseaseSurgerySurvival Ratemedicine.anatomical_structureTreatment OutcomeMetalsCardiologyFemaleStentsPatient SafetyCardiology and Cardiovascular MedicinebusinessArteryFollow-Up StudiesCardiovascular revascularization medicine : including molecular interventions
researchProduct

A biphasic calcium phosphate coating for potential drug delivery affects early osseointegration of titanium implants.

2016

Background Calcium phosphate (CaP) surface coatings may accelerate osseointegration and serve as a drug delivery system for mineral-binding biomolecules. In a pilot study, the impact of a commercially available, thin CaP coating on early osseous bone remodeling was compared with a modern, subtractive-treated rough surface (SLA-like) in an animal trial. Methods In 16 rabbits, 32 endosseous implants (CaP; n = 16, SLA-like; n = 16) were bilaterally inserted in the proximal tibia after randomization. After 2 and 4 weeks, bone-implant contact (BIC;%) in the cortical (cBIC) and the trabecular bone (sBIC) as well as volume of bone within the screw thread with the highest amount of new-formed bone …

Calcium PhosphatesCancer Researchchemistry.chemical_elementDentistry02 engineering and technologyengineering.materialCalciumOsseointegrationPathology and Forensic MedicineBone remodeling03 medical and health sciencesRandom Allocation0302 clinical medicineDrug Delivery SystemsCoatingOsseointegrationAnimalsDental ImplantsTitaniumChemistrybusiness.industryfungiDental Implantation Endosseous030206 dentistry021001 nanoscience & nanotechnologyBiphasic calcium phosphateTrabecular boneOtorhinolaryngologyDental Prosthesis DesignDrug deliveryModels AnimalengineeringPeriodonticsRabbitsOral Surgery0210 nano-technologyNuclear medicinebusinessTitaniumJournal of oral pathologymedicine : official publication of the International Association of Oral Pathologists and the American Academy of Oral Pathology
researchProduct

Thrombosis, fracture, and percutaneous removal of a patent foramen ovale closure device 1 month after successful deployment

2010

Several different devices have been developed for the percutaneous closure of interatrial defects and patent foramen ovale. Although the implantation of these devices is both safe and effective, a number of complications, both in the early and the late follow-up, may occur. We describe a case of device fracture manifested early (1 month after implantation) with the formation of massive thrombosis on the right atrial disc. The patient was treated with anticoagulants and the device was percutaneously retrieved. Our images allowed early noninvasive therapy and emphasize the need for echocardiographic follow-up early after implantation. © 2010 Wiley-Liss, Inc.

Cardiac Catheterizationmedicine.medical_specialtyTime FactorsPercutaneousSeptal Occluder DeviceForamen Ovale PatentProsthesis DesignRight atrialmedicineHumansRadiology Nuclear Medicine and imagingDevice Removalbusiness.industryAnticoagulantsThrombosisGeneral MedicineMiddle Agedmedicine.diseaseThrombosisProsthesis FailureSurgeryRadiographyTreatment OutcomePatent foramen ovaleFemaleCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealCatheterization and Cardiovascular Interventions
researchProduct