Search results for "Prosthesis"
showing 10 items of 719 documents
Reduced protein adsorption on plastics via direct plasma deposition of triethylene glycol monoallyl ether
1997
The direct plasma-induced deposition of tri(ethylene glycol) monoallyl ether is reported. RF plasma polymerization of this monomer was carried out under both continuous wave (CW) and pulsed plasma operation. The major focus of this work was optimization of the degree of retention of the C-O-C bonds of the starting monomer during the deposition process. This successfully was accomplished using low RF power during the CW runs and low RF duty cycles during the pulsed plasma experiments. Spectroscopic analysis of the plasma films revealed a strong dependence of film composition on the RF power and duty cycles employed. In particular, an unusually high level of film chemistry compositional contr…
Image quality with multifocal intraocular lenses and the effect of pupil size
2007
Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…
Primary endpoint results of the OMEGA Study: One-year clinical outcomes after implantation of a novel platinum chromium bare metal stent.
2014
Bare metal stents (BMS) have similar rates of death and myocardial infarction (MI) compared to drug-eluting stents (DES). DES lower repeat revascularization rates compared to BMS, but may have higher rates of late stent thrombosis (ST) potentially due to impaired endothelialization requiring longer dual anti-platelet therapy (DAPT). OMEGA evaluated a novel BMS designed to have improved deliverability and radiopacity, in comparison to currently available platforms.OMEGA was a prospective, multicenter, single-arm study enrolling 328 patients at 37 sites (US and Europe). Patients received the OMEGA stent (bare platinum chromium element stent) for the treatment of de novo native coronary artery…
Juxtapapillary duodenal diverticular bezor as an exceptional cause of biliary stent obstruction. Case report.
2007
INTRODUCTION: we describe the first case in literature of biliary stent obstruction by bezoar impaction in a iuxtapapillary duodenal diverticulum. CASE REPORT: this case illustrates an juxtapapillary duodenal diverticulum and bezoar in it causing obstructive jaundice in subject with two biliary stents for cholangiocarcinoma (Klatskin's tumor) in the absence of bile duct stones. RESULT: successful treatment with endoscopic stent removal and diverticulum toilette. Obstructive jaundice was cured after endoscopic removal of the bezoar and stent substitution. DISCUSSION: the presence of a bezoar and its possible contribution to the pathogenesis of pancreatitis in the presence of periampullary ex…
Large platelets but not putative endothelial progenitor cells are associated with low strut coverage after drug-eluting stent implantation
2015
Objectives This study assessed whether different subsets of circulating endothelial and putative endothelial progenitor cells (CEC and EPC) correlate with stent strut coverage (SSC) using second generation optical coherence tomography (OCT). Background Due to the lack of imaging modalities with a resolution down to the magnitude of a few cells, the influence of EPC on endothelialisation of drug-eluting stents has not been assessed in patients. Methods In 37 patients, SSC of everolimus-eluting stents was assessed by OCT 5-7months after stent implantation. Different subsets of EPC (CD34(+)KDR(+), CD34(+)KDR(+)CD45(dim), CD133(+), CD3(+)CD31(+)), CEC (CD31(+)CD45(-)CD146(+)), and CD31(+)CD45(-…
Mortality of ruptured abdominal aortic aneurysm with selective use of endovascular repair
2009
The aim of this review was to examine the results over a seven-year period of treatment for ruptured abdominal aortic aneurysm (RAAA). From 2002 on, our tertiary referral centre offered both open and endovascular (EVAR) treatment modalities for RAAA. All patients with a proven RAAA who were admitted into our hospital were included. Primary outcome measure was surgical mortality. In total 261 patients were admitted with suspicion of acute AAA. Of these, 175 (67%) had a RAAA, confirmed by computed tomography-scanning or at laparotomy. One hundred and fifty-nine patients (90.9%) were treated, 114 by open repair and 45 by EVAR. Overall mortality of patients treated was 25.2%, with an open repai…
Numerical simulations on periprosthetic bone remodeling: a systematic review
2021
Abstract Background and objective The aim of the present study was to review the literature concerning the analysis of periprosthetic bone remodeling through finite element (FE) simulation. Methods A systematic review was conducted on 9 databases, taking into account a ten-year time period (from 2009 until 2020). The inclusion criteria were: articles published in English, publication date after 2009, full text articles, articles containing the keywords both in the abstract and in the title. The articles were classified through the following parameters: dimensionality of the simulation, modelling of the bone-prosthesis interface, output parameters, type of simulated prosthesis, bone remodeli…
A biphasic calcium phosphate coating for potential drug delivery affects early osseointegration of titanium implants.
2016
Background Calcium phosphate (CaP) surface coatings may accelerate osseointegration and serve as a drug delivery system for mineral-binding biomolecules. In a pilot study, the impact of a commercially available, thin CaP coating on early osseous bone remodeling was compared with a modern, subtractive-treated rough surface (SLA-like) in an animal trial. Methods In 16 rabbits, 32 endosseous implants (CaP; n = 16, SLA-like; n = 16) were bilaterally inserted in the proximal tibia after randomization. After 2 and 4 weeks, bone-implant contact (BIC;%) in the cortical (cBIC) and the trabecular bone (sBIC) as well as volume of bone within the screw thread with the highest amount of new-formed bone …
A modified prosthesis for the treatment of malignant esophagotracheal fistula
1988
Esophagotracheal fistula is usually a sequela of irradiation or laser treatment of advanced carcinoma of the esophagus or the tracheobronchial tree. Resection of the tumor in these cases is not possible, and palliative bypass surgery is highly risky. The peroral placement of a prosthesis is less invasive, but conventional prostheses often fail to occlude the fistula. The authors regularly use an endoscopic multiple-diameter bougie for dilation. After dilation, a specially designed prosthesis is pushed through the tumor stenosis to block the fistula. This procedure can be done without general anesthesia. The funnels of conventional prostheses cannot cover the fistula when there is either a w…
Implantation of the modified endocapsular bending ring in pediatric cataract surgery using a viscoadaptive viscoelastic agent.
1999
Cataract surgery and intraocular lens (IOL) implantation in pediatric eyes remain controversial. Using a viscoadaptive viscoelastic agent, we implanted a modified capsular bending ring (CBR) as well as an acrylic IOL with a sharp-optic-edge design in the capsular bag. All operated eyes demonstrated a low postoperative inflammatory reaction and a clinically well-centered IOL. The band-shaped, sharp-edged CBR facilitates the creation of a sharp, discontinuous bend in the equatorial capsule, which prevents anterior and posterior capsule opacification. Combining the viscoadaptive viscoelastic agent and the CBR enhances the safety of primary and secondary posterior chamber IOL implantation in pe…