Search results for "Prosthesis"

showing 9 items of 719 documents

Primäre Ellenbogenprothese bei distalen Humerustrümmerfrakturen

2004

The use of hip- and shoulder arthroplasty in elderly patients for grossly displaced intraarticular fractures is being more and more accepted. Total elbow replacement (TER) has not been considered as an option for the treatment of extensively comminuted fractures of the distal humerus because surgeons feel the outcome is not predictable after TER generally. On the basis of a Medline literature research of this issue and the documented results based on the improvement of the designs of the implants, operative technique and the selection of patients, TER has a definite role in the treatment of some fractures of the distal humerus. We retrospectively reviewed forty-nine acute distal humeral fra…

musculoskeletal diseasesmedicine.medical_specialtyOsteosynthesisbusiness.industrymedicine.medical_treatmentElbowDistal humerusArthroplastyProsthesisSurgerymedicine.anatomical_structuremedicineSurgeryHumerusIn patientComplicationbusinessAktuelle Traumatologie
researchProduct

Aston Medical Duocentric® Reversed Prosthesis: Proposition of New Glenoid Component Design to Prevent Scapular Neck Notching

2015

Medialization of the center of rotation in reverse shoulder arthroplasty (RSA) results in greater excursion of the proximal humerus especially in adduction leading to a mechanical conflict against the neck of the scapula, thus creating a specific complication: scapular notching, in up to 90 % of RSA. We describe our third generation of RSA in Dijon, the Duocentric prosthesis. This prosthesis provides a new proposition to prevent the notching problem with an inferior overhang integrated to the glenoid baseplate. Such an inferior extension prevents the malpositioning of the hemisphere and resurfaces the “critical zone” preventing notching.Phenomenon while a smaller neck-shaft angle on the hum…

musculoskeletal diseasesmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentScapular notchingmusculoskeletal systemArthroplastyProsthesisSurgerymedicine.anatomical_structureNotchingScapulaEpiphysismedicineHumerusbusinessInstant centre of rotation
researchProduct

The effect of cement fixation on initial micromotion of the femoral component in condylar knee replacement

1992

Four fresh, cadaveric specimens were fitted with total knee replacements and mounted on a knee joint loading and measuring rig. Femoral component micromotion in the sagittal plane was measured with a transducer during flexion and extension of the specimen. Various condylar designs were used without and with cement. Movement followed a characteristic curve pattern and was less with cement fixation particularly for bone of low trabecular strength as determined by bone sample tests for stiffness. Cement fixation appears to be superior to cementless fixation.

musculoskeletal diseasesmedicine.medical_specialtymedicine.medical_treatmentKnee replacementDentistryIn Vitro TechniquesKnee JointProsthesis Designmedicine.disease_causeCondyleWeight-bearingWeight-BearingMotionCadavermedicineHumansOrthopedics and Sports MedicineFemurOrthodonticsbusiness.industryBone Cementsequipment and suppliesmusculoskeletal systemSagittal planesurgical procedures operativemedicine.anatomical_structureOrthopedic surgerySurgeryKnee ProsthesisbusinessCadaveric spasmInternational Orthopaedics
researchProduct

Appropriateness of surgery performed for abdominal aortic aneurysm at tertiary hospitals in Spain

2021

Background: The aim of this study was to analyze the appropriateness of the type of repair (open or endovascular) performed for abdominal aortic aneurysm (AAA) in five university hospitals in Spain, according to evidence-based recommendations. Methods: A multicenter, retrospective cross-sectional study of patients with AAA who underwent elective open surgical repair (OSR) or endovascular aneurysm repair (EVAR). Data were collected on demographic and clinical variables and type of surgical repair. A pair of vascular surgeons from each participating hospital performed a blinded assessment based on GRADE recommendations. The concordance between the two evaluators and the agreement between thei…

operativemedicine.medical_specialtyConcordancemedicine.medical_treatmentPatient characteristicsEndovascular aneurysm repairTertiary Care CentersBlood Vessel Prosthesis ImplantationSurgical proceduresAbdomenHumansMedicineAgedRetrospective StudiesSurgical repairAortic aneurysmbusiness.industryEndovascular Proceduresmedicine.diseaseUniversity hospitalAneurysmPatient preferenceAbdominal aortic aneurysmSurgeryCross-Sectional StudiesTreatment OutcomeElective Surgical ProceduresSpainCharlson comorbidity indexabdominalCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalInternational Angiology
researchProduct

Painful prosthesis: approaching the patient with persistent pain following total hip and knee arthroplasty.

2013

BACKGROUND: Symptomatic severe osteoarthritis and hip osteoporotic fractures are the main conditions requiring total hip arthroplasty (THA), whereas total knee arthroplasty (TKA) is mainly performed for pain, disability or deformity due to osteoarthritis. After surgery, some patients suffer from "painful prosthesis", which currently represents a clinical problem. METHODS: A systematic review of scientific literature has been performed. A panel of experts has examined the issue of persistent pain following total hip or knee arthroplasty, in order to characterize etiopathological mechanisms and define how to cope with this condition. RESULTS: Four major categories (non infective, septic, othe…

painful prosthesispersistent painSettore MED/33 - Malattie Apparato LocomotoreMini-Reviewknee arthroplastyhip arthroplasty
researchProduct

Periodontal Behavior Around Teeth Prepared with Finishing Line for Restoration with Fixed Prostheses. A Systematic Review and Meta-Analysis

2020

Background: The objective of this systematic review and meta-analysis was to analyze the periodontal behavior around teeth prepared with horizontal finishing crowns supporting fixed metal-ceramic and zirconia full coverage crowns and fixed partial dentures (FDPs). Materials and methods: An electronic search was conducted to locate relevant clinical trials in four databases: PubMed, Embase, Cochrane, and Scopus. A manual search was made in the reference sections of the articles identified for any additional articles. No restrictions were applied regarding year of publication or language. The following variables were considered in quantitative and qualitative analysis: probing pocket depth (P…

periodontal prosthesisBleeding on probingDentistrylcsh:MedicineReviewPlaque controlPeriodontal Prosthesis03 medical and health sciences0302 clinical medicineQualitative analysisstomatognathic systemUntreated controlzirconium oxideMedicinebiological factorbusiness.industryDental prosthesislcsh:Rdental prosthesis030206 dentistryGeneral Medicinestomatognathic diseases030220 oncology & carcinogenesisMeta-analysismedicine.symptombusinessGingival marginmetal ceramic restorationsJournal of Clinical Medicine
researchProduct

bbFISH-ing in the sonication fluid

2019

Abstract By 2030, the annual number of combined total hip and knee arthroplasty is estimated to reach 3.5 to 4 million in the US alone. In the context of a constant increase of the number of primary and revision total hip and knee arthroplasty, an increased risk of complication is expected. Prosthetic joint infections (PJIs) represent major cause of healthcare expenditure and morbidity. PJI still remain the most common and feared arthroplasty complication. A rapid and correct diagnosis of infection is decisive for a correct therapeutical management. In this setting, the Academic Emergency Hospital Sibiu adopted and implemented, with the beginning of September 2016, a new strategy for the di…

sonicationMaleProsthetic joint infectionmedicine.medical_specialtyPJIProsthesis-Related InfectionsArthroplasty Replacement Hipmedicine.medical_treatmentSonication7100Observational StudydiagnosticContext (language use)biofilm03 medical and health sciences0302 clinical medicineStaphylococcus epidermidisRNA Ribosomal 16SInternal medicineSynovial FluidmedicineHumans030212 general & internal medicineArthroplasty Replacement KneeIn Situ Hybridization FluorescenceAgedAged 80 and overBacteriological Techniquesbiologybusiness.industryRalstonia pickettiimolecular diagnosticBacterial InfectionsGeneral MedicineGold standard (test)Middle Agedbiology.organism_classificationArthroplastyRNA BacterialConnective Tissue030220 oncology & carcinogenesisPositive culturebbFISHFemaleComplicationbusinessResearch ArticleMedicine
researchProduct

Optical quality of hyperopic and myopic phakic intraocular lenses

2013

Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…

steep corneal curvatureintravitreallacrimal fossaRefractive errorvisual acuitygenetic structurespterygium surgerystandard automated perimetryComa (optics)BlindnessPhakic intraocular lenslaw.inventionsubconjunctival bevacizumab injectionCorneaLens Implantation Intraocularlcsh:Ophthalmologylawmodified deep anterior lamellar keratoplastyMitomycin CMaterials TestingAutogenous tissue graftingProspective StudiesDioptreoptical qualityshort wave automated perimetryexcimer lasernon-proliferative diabetic retinopathyMean deviationin vitroheavy silicone oilBevacizumabLens (optics)Aberrations of the eyeSpherical aberrationHyperopiaAntimicrobial effectOriginal ArticleTriamcinolone acetonidehuman trabecular meshwork cellsPhakic Intraocular Lensesmedicine.medical_specialtyImaging in glaucomadisability evaluationconventional silicone oiltriamcinoloneProsthesis DesignKeratoconusphotorefractive keratectomyOphthalmologygrowth factorsmedicineHumansmyopiamyopic implantable collamer lensshort fluctuationsWavefrontmacular edemaoptical coherence tomographyendophthalmitis agentsbusiness.industrybranch retinal vein occlusionretinal nerve fiber layerpterygium recurrencemedicine.diseaseeye diseasesOphthalmologypediatricwavefront aberrationsquality of lifelcsh:RE1-994bypass surgeryHyperopic implantable collamer lenslacrimal drainage systemsense organsbusinessIndian Journal of Ophthalmology
researchProduct

Peri-Implant Behavior of Tissue Level Dental Implants with a Convergent Neck

2021

Introduction: The aim of this retrospective study was to analyze the radiographic peri-implant bone loss of bone level implants and tissue level implants with a convergent neck in screw-retained single crowns and in screw-retained fixed partial prostheses, after two years of functional loading. Materials and methods: The sample was divided into two groups according to their type: Group I: supracrestal implants with convergent transmucosal neck

tissue levelHealth Toxicology and MutagenesisRadiographymedicine.medical_treatmentPeriAlveolar Bone LossDentistryMandibleProsthesisArticleBones.Dental implants.03 medical and health sciences0302 clinical medicinebone lossMaxillamedicineHumansHuesos.Dental Restoration FailureOdontología restauradora.Bone levelRetrospective StudiesDental Implantsbusiness.industryfixed partial prosthesisPrótesis dentales.Dientes - Implantes.RPublic Health Environmental and Occupational HealthMandibleTissue levelbone level030206 dentistryDentures.Treatment Outcomesingle crownMaxillaMedicineImplantbusinessDentistry Operative.Follow-Up Studies030215 immunologyInternational Journal of Environmental Research and Public Health
researchProduct