Search results for "Prosthesis"
showing 10 items of 719 documents
A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.
2014
Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…
Surgical complications in zygomatic implants : a systematic review
2016
Background The use of zygomatic implants in the prosthetic rehabilitation of the patient with severe maxillary bone atrophy is another therapeutic alternative, not exempt from complications. The main objective of this review is to analyze and describe the most frequent surgical complications associated with the use of zygomatic implants. Material and Methods An electronic database search on PubMed, along with a manual search, without taking into account date nor language, was undertaken by two observers, selecting studies that comprised a study period from 6 to 12 months, any type of clinical trial, and series that included a follow-up and/or review period during the aforementioned margin, …
Endosseous dental implant fractures an analysis of 21 cases
2008
Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic rehabilitation involved, the number of abutments and pontics, the presence or absence of distal extensions or cantilevers, and loading time to fracture. Implant fracture was more common in males than in females (15:4), and the mean patient age was 56.9 years. Most cases (n = 19) corresponded to implant-supported fixed prostheses - 16 with cantilevers of different lengths ? while only two fractured implants were supporting overdentures instead…
Influence of prefabricated post material on restored teeth: fracture strength and stress distribution.
2006
This work studied how prefabricated intraradicular post material affects the mechanical performance of restored teeth. The effect of using two different materials (glass fiber and stainless steel) with significantly different elastic moduli was studied.A combined theoretical and experimental method was used: first, an experimental fracture strength test was performed on 60 extracted human maxillary central incisors. The teeth were decoronated, treated endodontically and restored, 30 with glass fiber posts and 30 with stainless steel posts. The data were recorded and the results compared using an ANOVA test. Then, the finite element technique was used to develop a model of the restored tooth…
Retentive strengths of cast gold crowns using glass ionomer, compomer, or resin cement
1998
The retention forces of a newly developed compomer cement (Dyract Cem), a glass ionomer cement (Ketac Cem Aplicap), and a resin cement (F21) were examined.Cemented cast gold crowns were removed along the path of insertion with a Zwick universal testing device. The impact of both a cured and a noncured additional bonding layer that were applied to the inner surface of the crowns was examined across the Dyract Cem group.The mean adhesive strength was measured at 2.36 +/- 0.69 N/mm2 in the Ketac Cem group, at 0.60 +/- 0.28 N/mm2 in the F21 group, and at 1.85 +/- 0.94 N/mm2 in the Dyract Cem group, respectively. The application of an additional bonding layer to the inner surface of the crowns d…
Influence of prefabricated post dimensions on restored maxillary central incisors
2007
summary The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to …
In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents
2005
Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…
Premolars restored with posts of different materials: fatigue analysis
2011
Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…
Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.
2009
Summary Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…
Removal of a migrated dental implant from a maxillary sinus through an intraoral approach: A case report
2021
Background The replacement of maxillary posterior teeth often challenges the clinician due to bone resorption after dental exodontia and low bone quality. Currently, attempts are being made to shorten treatment times by placing implants simultaneously to sinus lift procedures in borderline cases, which can lead to complications such as displacement of implants into the maxillary sinus. Clinical case A 54-year-old patient who was planned for complete rehabilitation of the maxilla through a fixed implant-supported prosthesis on 6 implants. At the level of the 3rd sextant, a sinus lift was performed with a lateral window approach (Caldwell-Luc type) and the simultaneous placement of two implan…