Search results for "Prosthesis"
showing 10 items of 719 documents
Predictors of short‐ and long‐term outcomes of patients undergoing transcatheter mitral valve edge‐to‐edge repair
2020
Objectives Transcatheter mitral valve repair (TMVR) by edge-to-edge therapy is an established treatment for severe mitral valve regurgitation (MR). Background Symptomatic and prognostic benefit in functional MR has been shown recently; nevertheless, data on long-term outcomes are sparse. Methods and results We analyzed survival of patients treated with isolated edge-to-edge repair from June 2010 to March 2018 (primarily combined edge-to-edge repair with other mitral valve interventions was excluded) in a retrospective monocentric study. Overall, 627 consecutive patients (47.0% females, 78.6 years in mean) were included. Leading etiology was functional MR (57.4%). Follow-up regarding surviva…
Reduced-dose computed tomography is the most accurate method to measure ceramic hip resurfacing cup version
2020
Background: A precise assessment of cup version after hip resurfacing is generally requested, especially in clinical trials or in case of complications. Aims: To identify which diagnostic imaging modality, between AP pelvis X-rays, the AP Pelvis CT Scout image and reduced-dose axial CT scan, is the most precise to assess cup version of an all-ceramic hip resurfacing implant in a first-in-human clinical trial. Methods: We retrospectively assessed the cup version of the first 20 patients who underwent an experimental all-ceramic hip resurfacing on AP pelvis X-rays (0.8 mSv of radiation), AP pelvis CT scout images (0.016 mSv) and axial CT slices performed using a reduced dose protocol (0.3 mSv…
Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management
2019
Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…
Impression of multiple implants using photogrammetry: Description of technique and case presentation
2014
Aim: To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Study Design: Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abut - ments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 image…
Complications associated with the ball, bar and locator attachments for implant-supported overdentures
2010
Background: The purpose of this clinical study was to evaluate the complications associated with the different attachments used in implant-supported overdentures, including prosthetic problems and implant failures. A comparison of ball, bar and Locator (Zest Anchors, Inc, homepage, Escondido, CA, USA) attachments, in completely edentulous patients with two, three or four implants, was conducted. Material and methods: A total of 36 edentulous patients (20 female, 16 male) with a mean age of 66.3 years, were enrolled in the study. The patients were treated with 95 implants, for the prosthetic restoration of the maxilla or the mandible. The mean follow-up time was 41.17 months. Prosthetic comp…
Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.
2014
Objective To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. Materials and methods A cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5 years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (…
Silicone-Silver Penile Prosthesis: Description, Operative Approach and Results
1980
A silicone penile prosthesis in which silver wires are embedded to allow for voluntary bending of the penis for urination and resting position and for straightening for intercourse is described. The implantation is done via a hemicircular incision on the dorsum of the penis in the sulcus coronarius. Buck's fascia is identified and opened, and the corpora are dilated up to 30F. After the exact length is determined with a special sizer the prosthesis is slipped into each corpus cavernosum. The advantage of this approach is the optimal insertion of the prosthesis distal to the sulcus coronarius, thereby preventing kinking of the glans during intercourse. Our experiences with the implantation i…
A Human-Humanoid Interaction Through the Use of BCI for Locked-In ALS Patients Using Neuro-Biological Feedback Fusion.
2018
This paper illustrates a new architecture for a human–humanoid interaction based on EEG-brain computer interface (EEG-BCI) for patients affected by locked-in syndrome caused by Amyotrophic Lateral Sclerosis (ALS). The proposed architecture is able to recognise users’ mental state accordingly to the biofeedback factor $\text {B}_{\text f}$ , based on users’ attention, intention, and focus, that is used to elicit a robot to perform customised behaviours. Experiments have been conducted with a population of eight subjects: four ALS patients in a near locked-in status with normal ocular movement and four healthy control subjects enrolled for age, education, and computer expertise. The results s…
Preserving the abductor mechanism in robotic THR: the influence of stem design and cutterpath.
2004
The tip of the greater trochanter is the attachment site for the abductor muscles of the hip joint. Its preservation in robotic and conventional THR is important for normal gait. The effect of different stem designs and robotic cutterpaths on the preservation of the trochanter tip is examined.One anatomical stem, one straight stem, and one stem specifically designed for robotic THR were implanted virtually in CT scans of osteoarthrotic hip joints using the Torch preoperative planning unit (URS-ortho). In transverse sections of the trochanter tip, dimensions of the trochanter area removed by the milling tool were recorded for each stem design and different cutterpaths (3-axis versus 5-axis m…
Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement su…
2013
Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified …