Search results for "Prosthesis"

showing 10 items of 719 documents

Outcomes of complex femorodistal sequential autologous vein and biologic prosthesis composite bypass grafts

2014

Objective Femorodistal autologous vein bypass proves to be the preferred surgical therapy for long arterial occlusions and provides excellent early and long-term results in critical lower limb ischemia. Whenever vein length was insufficient and two distal outflow arteries were present, a sequential composite bypass configuration was chosen with human umbilical vein (HUV) or ovine collagen prosthesis (Omniflow II; Bio Nova International Pty Ltd, North Melbourne, Australia) as the proximal prosthetic part of the bypass. Single-center experience with this technique regarding limb salvage, graft function, secondary reinterventions, and biodegeneration is presented. Methods Between January 1998 …

MaleUmbilical Veinsmedicine.medical_specialtyTime Factorsmedicine.medical_treatmentIschemiaProsthesis DesignProsthesisBlood Vessel Prosthesis ImplantationPeripheral Arterial DiseaseRisk FactorsBlood vessel prosthesismedicineAnimalsHumansVascular PatencyAutograftsVascular PatencyAgedRetrospective StudiesAged 80 and overBioprosthesisUltrasonography Doppler DuplexSheepmedicine.diagnostic_testbusiness.industryRetrospective cohort studyMiddle AgedLimb Salvagemedicine.diseaseThrombosisBlood Vessel ProsthesisSurgeryFemoral ArteryRadiographyTreatment OutcomeAngiographyHeterograftsFemaleSurgerymedicine.symptomCardiology and Cardiovascular MedicineClaudicationbusinessJournal of Vascular Surgery
researchProduct

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2012

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…

MaleVisual acuitygenetic structuresDesenho de prótesesmedicine.medical_treatmentVisual AcuityEmmetropiaIntraocular lensProsthesis designMyopia/surgerylaw.inventionNear visionLens Implantation Intraocularlcsh:OphthalmologylawTonometry ocularMyopiaProspective StudiesLenses IntraocularLens crystalline/surgeryAcuidade visualGeneral MedicineMiddle AgedLens (optics)HyperopiaTreatment OutcomeFemalemedicine.symptomLens crystallinemedicine.medical_specialtyVisual acuityMiopiaRefractive lens exchangeProsthesis DesignStatistics NonparametricOphthalmologyLens CrystallinemedicineHumansHyperopia/physiopathologyHipermetropiaCristalinoAgedPhacoemulsificationbusiness.industryReproducibility of ResultsPhacoemulsificationPresbyopiamedicine.diseaseeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994OptometryImplantação de lentes intraocularessense organsbusinessArquivos Brasileiros de Oftalmologia
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

2007

To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityCorrelationLens Implantation IntraocularHumansMedicineContrast (vision)Prospective Studiesmedia_commonLenses Intraocularbusiness.industryPupilMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerysense organsSpatial frequencymedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.

2009

Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…

MaleVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensExtractionFunctional LateralityTratamiento médico0302 clinical medicineLens Implantation IntraocularMyopiaContrast (vision)MedicineRetinal-Detachmentmedia_commonVistaLenses IntraocularVision BinocularDistanceHigh myopiaRetinal detachmentGeneral MedicineMiddle AgedQualityTreatment OutcomeOftalmologíaFemalemedicine.symptomPhotopic visionRiskmedia_common.quotation_subjectProsthesis DesignContrast Sensitivity03 medical and health sciencesHumansMonocularPhacoemulsificationbusiness.industryMultifocal Iolmedicine.diseaseeye diseasesVisual PerformanceOphthalmology030221 ophthalmology & optometryOptometrysense organsbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Ma…

2012

Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Me…

MaleZIRCONIUM ALLOYSDentistrychemistry.chemical_elementMandiblelaw.inventionDouble-Blind MethodRandomized controlled triallawalloyDental Prosthesis DesignHumansJaw EdentulousMedicinebone level implantBone leveledentulous mandibleORAL-HEALTHAdverse effectGeneral DentistryAgedAged 80 and overTitaniumSUPPORTED OVERDENTURESbusiness.industrySPLIT-MOUTHDental Implantation EndosseousTitanium alloySoft tissueSUCCESSOSSEOINTEGRATED IMPLANTSMiddle Agedddc:617.6Treatment OutcomeDental Prosthesis Designchemistryddc:618.97DENTAL IMPLANTSFemaleImplantZirconiumOral Surgerydouble-blindLocatorbusinessFOLLOW-UPITI IMPLANTSRCTTitaniumClinical implant dentistry and related research
researchProduct

Cryptogenic stroke and atrial fibrillation in a real-world population: the role of insertable cardiac monitors

2020

AbstractThe incidence of atrial fibrillation (AF) in cryptogenic stroke (CS) patients has been studied in carefully controlled clinical trials, but real-world data are limited. We investigated the incidence of AF in clinical practice among CS patients with an insertable cardiac monitor (ICM) placed for AF detection. Patients with CS admitted to our Stroke Unit were included in the study; they received an ICM and were monitored for up to 3 years for AF detection. All detected AF episodes of at least 120 sec were considered. From March 2016 to March 2019, 58 patients (mean age 68.1 ± 9.3 years, 67% male) received an ICM to detect AF after a CS. No patients were lost to follow-up. AF was detec…

Malelcsh:MedicineKaplan-Meier Estimate030204 cardiovascular system & hematologySeverity of Illness Index0302 clinical medicineRisk Factorslcsh:ScienceStrokeMultidisciplinaryIncidence (epidemiology)QRNeuro-vascular interactionsAtrial fibrillationICM deviceStrokeTreatment OutcomeCardiologyMedicineFemaleSettore MED/26 - Neurologiamedicine.symptommedicine.medical_specialtyScienceNeurophysiologyCryptogenic strokeAsymptomaticArticleProsthesis ImplantationLoop recorder03 medical and health sciencesInternal medicinemedicineHumansAgedMonitoring Physiologicbusiness.industrylcsh:RAnticoagulantsmedicine.diseaseAtrial fibrillationClinical trialCryptogenic strokeAnticoagulant therapyElectrocardiography AmbulatoryCardiac monitorslcsh:Qbusiness030217 neurology & neurosurgeryFollow-Up StudiesScientific Reports
researchProduct

Series of fibrinous inflammation after implantation of capsular tension rings

2014

Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…

Malemedicine.medical_specialtyAfter cataractTopical treatmentMethylmethacrylatemedicine.disease_causeProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansUniversity medicalDevice RemovalAgedRetrospective StudiesAged 80 and overEndophthalmitisFibrinPhacoemulsificationAmoebocyte lysatebusiness.industrySmear testsFibrinous inflammationProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyMethacrylatesFemaleSurgeryIrritationbusinessJournal of Cataract and Refractive Surgery
researchProduct

Less invasive (common) femoral artery aneurysm repair using endografts and limited dissection

2013

Objective We report our experience with the treatment of femoral artery aneurysms (FAAs) under local anaesthesia with limited dissection, using endografts to facilitate the proximal anastomosis and some distal anastomoses. Method Between January 2006 and December 2010, six males, mean age 72 years (range, 65–80 years) with FAAs were treated at the University Hospital of Zurich. All operations were performed under local anaesthesia with analgosedation, except for one performed under spinal anaesthesia. After limited dissection and puncture of the anterior wall of the FAA, a sheath and a self-expanding endograft were introduced over a guide wire and with fluoroscopy they were guided intralumi…

Malemedicine.medical_specialtyAnastomosismedicine.medical_treatmentEndograft610 Medicine & healthFemoral arteryDissection (medical)AnastomosisSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineAneurysmmedicine.arteryDeep Femoral ArteryHumansMedicineAgedMedicine(all)Aged 80 and over10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresBalloon catheterExternal iliac arteryStentmedicine.diseaseAneurysmBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryFemoral ArteryCommon femoral arteryFemaleSurgeryRadiologyCardiology and Cardiovascular MedicinebusinessCommon femoral artery Aneurysm Endograft Anastomosis
researchProduct

ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA

2009

This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…

Malemedicine.medical_specialtyAortic DiseasesContrast MediaAorta ThoracicBlood Vessel Prosthesis ImplantationElectrocardiographyPostoperative ComplicationsAortic valve replacementECG gatingmedicine.arteryAscending aortaMultidetector computed tomographymedicineHumansRadiology Nuclear Medicine and imagingAortic valve prosthesicardiovascular diseasesAortaNeuroradiologyAortamedicine.diagnostic_testbusiness.industryMultidetector CTUltrasoundInterventional radiologySettore MED/23 - Chirurgia CardiacaGeneral MedicineMiddle Agedmedicine.diseaseIopamidolAortic valve replacementTreatment OutcomeEchocardiographyEcg gatingcardiovascular systemRadiographic Image Interpretation Computer-AssistedFemaleRadiologybusinessTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct