Search results for "Prosthesis"
showing 10 items of 719 documents
Impact of Accessory Renal Artery Coverage on Renal Function during Endovascular Aortic Aneurysm Repair.
2021
Background Long-term outcomes of accessory renal artery (ARA) coverage after endovascular aneurysm repair (EVAR) are unknown. We analyzed the impact of ARA coverage on renal function long-term. Methods This retrospective, monocentric study included patients treated by EVAR between 2008 and 2016. Patients with at least one ARA covered with EVAR (ARA group) were compared with patients with no covered ARA (control group). Renal function was determined by estimating the glomerular filtration rate (eGFR) and graded according to chronic kidney disease (CKD) classification stages. Results A total of 184 patients were included (ARA group, n = 25; control group, n = 159). Renal risk factors were sim…
Two-stage transperineal management of posterior urethral strictures or bladder neck contractures associated with urinary incontinence after prostate …
2007
Objectives: The treatment of posterior urethral strictures or bladder neck contracture associated with severe urinary incontinence after prostate surgery and failure of endoscopic treatments is controversial. We report our experience with a transperineal approach in two steps: end-to-end urethroplasty/anastomosis and subsequent artificial urinary sphincter implantation.Methods: Between September 2001 and January 2005, we observed six patients (58-68 yr old), with a combination of severe urinary incontinence and posterior urethral stricture with anastomotic bladder neck contracture after prostate surgery. In all cases, repeated endoscopic treatments of the strictures failed. The patients und…
Early outcomes with a single-sided access endovascular stent
2018
Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …
Risk Factors for Failure of Male Slings and Artificial Urinary Sphincters: Results from a Large Middle European Cohort Study.
2016
<b><i>Introduction:</i></b> We analysed the impact of predefined risk factors: age, diabetes, history of pelvic irradiation, prior surgery for stress urinary incontinence (SUI), prior urethral stricture, additional procedure during SUI surgery, duration of incontinence, ASA-classification and cause for incontinence on failure and complications in male SUI surgery. <b><i>Materials and Methods:</i></b> We retrospectively identified 506 patients with an artificial urinary sphincter (AUS) and 513 patients with a male sling (MS) in a multicenter cohort study. Complication rates were correlated to the risk factors in univariate analysis. Subsequentl…
The TiLOOP® Male Sling: Did We Forejudge.
2017
<b><i>Introduction:</i></b> To evaluate the safety and efficacy of the TiLOOP® male sling (pfm medical, Cologne, Germany) used in the treatment for male stress urinary incontinence (SUI). <b><i>Material and Methods:</i></b> We retrospectively evaluated a total of 34 patients with a TiLOOP® male sling. Perioperative complication rates were assessed and validated questionnaires were prospectively evaluated to assess quality of life and satisfaction rate. Outcome and complication rates were analysed by using descriptive statistics. Correlation of continence outcome and risk factors was performed with the chi-square test. A <i>p</i> va…
Initial Clinical Experience Using the Low-Profile Altura Endograft System With Double D-Shaped Proximal Stents for Endovascular Aneurysm Repair.
2018
Purpose: To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double “D-shaped” stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. Methods: From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, an…
Immunoglobulin G4-Related Aortitis and Severe Aortic Valve Stenosis Treated With Transcatheter Aortic Valve Replacement and Immunosuppression.
2021
Abstract IgG4-related disease is an immune-mediated fibro-inflammatory disorder with multisystemic involvement. Aortitis and peri-aortitis are the most common cardiovascular manifestations of the disease. We present the case of a 65-year-old man with symptomatic severe aortic stenosis and concomitant IgG4 aortitis. The diagnosis was confirmed by IgG4 serum levels, positive positron emission computed tomography (PET-CT) scans, and pathology from mediastinal dissection. Surgical aortic valve replacement (SAVR) was unfeasible owing to extensive mediastinal fibrosis, and transcatheter aortic valve replacement (TAVR) was successfully performed. As ascending aorta access for SAVR in IgG4 aortitis…
CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies
2013
PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…
The Gore Hybrid Vascular Graft in renovisceral debranching for complex aortic aneurysm repair.
2016
Objective This study reports our initial experience with the Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) for staged hybrid open renovisceral debranching and endovascular aneurysm repair in patients affected by thoracoabdominal aortic aneurysms and pararenal abdominal aortic aneurysms (PAAAs). Methods Between December 2012 and December 2013, we analyzed outcomes of 13 patients who underwent open surgical debranching of renovisceral vessels for thoracoabdominal aortic aneurysm and PAAAs. All patients were considered at high risk for conventional surgery. Inclusion criterion was treatment by open surgical debranching of at least one visceral artery (renal artery…