Search results for "Prosthesis"
showing 10 items of 719 documents
Collected World Experience About the Performance of the Snorkel/Chimney Endovascular Technique in the Treatment of Complex Aortic Pathologies
2015
OBJECTIVES: We sought to analyze the collected worldwide experience with use of snorkel/chimney endovascular aneurysm repair (EVAR) for complex abdominal aneurysm treatment. BACKGROUND: EVAR has largely replaced open surgery worldwide for anatomically suitable aortic aneurysms. Lack of availability of fenestrated and branched devices has encouraged an alternative strategy utilizing parallel or snorkel/chimney grafts (ch-EVAR). METHODS: Clinical and radiographic information was retrospectively reviewed and analyzed on 517 patients treated by ch-EVAR from 2008 from 2014 by prearranged defined and documented protocols. RESULTS: A total of 119 patients in US centers and 398 in European centers …
Endoluminal Stent-Graft Relining of Visceral Artery Bypass Grafts to Treat Perigraft Seroma
2013
PURPOSE: To describe the endovascular treatment of intra-abdominal perigraft seromas associated with small-caliber expanded polytetrafluoroethylene (ePTFE) grafts. CASE REPORTS: Two patients who underwent hybrid repair of thoracoabdominal aortic aneurysms in which renovisceral bypass grafts were implanted presented with large, symptomatic perigraft seromas. The 5- to 8-mm-diameter ePTFE bypass grafts believed to be involved in the seromas were successfully relined with self-expanding Viabahn stent-grafts in percutaneous procedures. The patients' symptoms were relieved, and imaging follow-up (18 and 10 months, respectively) has shown near complete resorption of the seromas. CONCLUSION: It is…
Long-term results after operative treatment of femoral neck fractures with ceramic head prostheses.
2001
ABSTRACT From 1 985-1 990, a total of 277 elderly patients underwent hemiarthroplasty using a ceramic head prosthesis. Average patient age was 81.7 years. Of these, 77 patients were available for follow-up examination in 1993. A standardized score was calculated assessing activity, gait, and hip pain; the average score was 58 out of 78 possible points. Three patients had hip pain, and in 4 patients, radiographic examination revealed protrusio acetabuli. Two of 4 patients underwent revision surgery for replacement of the cup, leaving the stem in situ. Because of the small number of prosthetic-related complications, hemiarthroplasty using a ceramic head prosthesis is the recommended surgical …
Mechanisms of Disease: molecular insights into aseptic loosening of orthopedic implants
2007
Despite the success of treating rheumatic disorders with biologic therapies, joint replacement surgery still remains the final treatment option in many cases. Approximately 1.5 million joint arthroplastic operations are performed annually worldwide. Implant failure due to massive bone loss and aseptic loosening of prostheses, however, is a major complication of joint replacement, which can lead to high socioeconomic burdens both for the individual patient and for health-care systems. To date, there is no approved drug therapy to prevent or inhibit periprosthetic osteolysis, and aseptic loosening of prostheses can only be overcome by surgical revision. Research during the past decade, howeve…
Four-year outcomes of full-arch fixed dental prostheses using CAD/CAM frameworks : a retrospective review of 15 cases
2018
The aim of this report is to analyze the clinical performance of 20 full-arch implant-supported titanium frameworks using CAD/CAM (Computer-Aided Design and Computer-Aided Manufacturing) technology. One hundred and four implants were placed in 15 patients using a one-stage protocol. After planning the location of all implants via 3-dimensional software (NobleClinician), 4-8 implants were placed in each edentulous arch based on anatomical measurements. Twenty edentulous arches were treated with full arch implant-supported fixed dental prostheses utilizing CAD/CAM milled titanium frameworks . All patients were followed up for 48±4 months. Clinical performance of the implants and restorations …
Volar and dorsal mid-shaft forearm plating using DCP and LC-DCP: interference with the interosseous membrane and forearm-kinematics.
2010
Purpose To clarify if dorsal plate osteosynthesis of the forearm shaft is associated with impingement of the interosseous membrane (IOM) and if rotational kinematics of the forearm are influenced. Background Forearm fractures are treated by separate incisions. Osteosynthesis via one approach in proximal forearm fractures was associated with higher rates of synostosis. It has been claimed that this is due to IOM impingement. Materials and methods 16 forearms of fresh frozen cadavers were dissected until only radius, ulna and the IOM remained. To preserve physiological forearm rotation, the elbow joint, the distal radio-ulnar joint and the carpus remained intact. In group 1, LC-DC and DC plat…
Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controll…
2015
OBJECTIVE: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS: This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of l…
Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…
2015
BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …
Biologic response of inguinal hernia prosthetics: a comparative study of conventional static meshes versus 3D dynamic implants.
2015
Despite improvements in prosthetics and surgical techniques, the rate of complications following inguinal hernia repair remains high. Among these, discomfort and chronic pain have become a source of increasing concern among surgeons. Poor quality of tissue ingrowth, such as thin scar plates or shrinking scars-typical results with conventional static implants and plugs-may contribute to these adverse events. Recently, a new type of 3D dynamically responsive implant was introduced to the market. This device, designed to be placed fixation-free, seems to induce ingrowth of viable and structured tissue instead of regressive fibrotic scarring. To elucidate the differences in biologic response be…
Non-cross-linked porcine-based collagen I-III membranes do not require high vascularization rates for their integration within the implantation bed: …
2012
There are conflicting reports concerning the tissue reaction of small animals to porcine-based, non-cross-linked collagen I-III membranes/matrices for use in guided tissue/bone regeneration. The fast degradation of these membranes/matrices combined with transmembrane vascularization within 4 weeks has been observed in rats compared with the slow vascularization and continuous integration observed in mice. The aim of the present study was to analyze the tissue reaction to a porcine-based non-cross-linked collagen I-III membrane in mice. Using a subcutaneous implantation model, the membrane was implanted subcutaneously in mice for up to 60 days. The extent of scaffold vascularization, tissue …