Search results for "Prosthesis"
showing 10 items of 719 documents
Predilation, sizing and post-dilation scoring in patients undergoing everolimus-eluting bioresorbable scaffold implantation for prediction of cardiac…
2017
Aims: The aim of the study was to develop a scoring model to evaluate the quality of bioresorbable vascular scaffold (BVS) implantation and determine the model's usefulness in predicting adverse cardiac events. Methods and results: The implantation technique and clinical outcomes of 1,736 lesions treated with BVS were analysed using the GHOST-EU registry. Predilation, scaffold sizing, and post-dilation (PSP) were scored according to the hazard model derived from the weight of these variables. The primary end-point was a one-year device-oriented composite endpoint (DoCE) composed of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation. Def…
Clinical outcomes of patients with diabetes mellitus treated with Absorb bioresorbable vascular scaffolds: a subanalysis of the European Multicentre …
2017
Background Data on the clinical performance of bioresorbable scaffolds in patients with diabetes mellitus (DM) are still limited. The present study reported 1-year clinical outcomes associated with the use of everolimus-eluting bioresorbable vascular scaffolds (Absorb BVS; Abbott Vascular, Santa Clara, CA) in DM patients. Methods and Results This was a subanalysis from the GHOST-EU (Gauging coronary Healing with biOresorbable Scaffolding plaTforms in Europe) multicenter retrospective registry including patients treated with Absorb BVS between November 2011 and September 2014. In this study, a comparative analysis stratified according to DM was performed. The primary endpoint was target lesi…
Everolimus eluting bioresorbable vascular scaffolds in patients with acute coronary syndromes: Two‐year results from the German‐Austrian ABSORB regis…
2021
Abstract Objectives To identify potential differences in 2‐year outcome between patients who underwent coronary revascularization using bioresorbable vascular scafffolds (BVS) in stable coronary artery disease (CAD) and acute coronary syndromes (ACS). Background Data from randomized trials suggest a significantly higher event rate following coronary revascularization using everolimus‐eluting BVS as compared to new generation drug eluting stents. Whether particular patient subgroups are at increased risk for scaffold thrombosis and target lesion failure (TLF) has not clearly been demonstrated. Methods German‐Austrian ABSORB RegIstRy is a prospective all‐comer multi‐center observational study…
In-Vitro Investigation of Fatigue and Fracture Behavior of Transmucosal versus Submerged Bone Level Implants Used in Fixed Prosthesis
2021
Background: The present in vitro study aimed to investigate the fatigue performance of different dental fixtures in two different emergence profiles. Biological failures are frequently reported because the problem canonly be solved by replacing a failing implant with a new one. Clinicians addressed minor mechanical failures, such as bending, loosening or the fracture of screws, abutment, or the entire prosthesis, by simply replacing or fixing them. Methods: Transmucosal and submerged bone-level dental implants underwent fatigue strength tests (statical and dynamical performance) by a standardized test: UNI EN ISO 14801:2016. Two types of emergence profiles (Premium sub-crestal straight impl…
Hydrogels in maxillofacial prosthesis
2017
Background: There is a growing need for prosthetic replacements in humans due to various reasons. Oro-facial deformities contribute more for these treatment modalities due to impairment in both function and esthetics. Biomaterials play an important role in replacing any form of defects. Selection of a good biomaterial is of prime importance as these materials determine the success of the treatment outcome. Acrylic resins and silicones are the most popular materials for replacing the lost tissues as far as the maxillofacial prosthesis is concerned. But these materials only help in covering the defect and give a very little therapeutic effect. Acrylic resins are very rigid materials and are l…
The Patellofemoral Arthroplasty: The Great Solution, the Great Problem
2012
Unfortunately, many orthopedic surgeons believe that the definite solution for eliminating anterior knee pain in a young patient with multiple operations is the patellofemoral prosthesis (“The Great Solution”). But, they fail to ask themselves the most important question; what is causing the pain? When a patellofemoral prosthesis is implanted in these young patients without finding out the cause of the pain, a more serious problem could be created with a worse solution (“The Great Problem”). The cases we present spotlight this abuse.
Scaffold vascularization in vivo driven by primary human osteoblasts in concert with host inflammatory cells.
2011
Successful cell-based tissue engineering requires a rapid and thorough vascularization in order to ensure long-term implant survival and tissue integration. The vascularization of a scaffold is a complex process, and is modulated by the presence of transplanted cells, exogenous and endogenous signaling proteins, and the host tissue reaction, among other influencing factors. This paper presents evidence for the significance of pre-seeded osteoblasts for the in vivo vascularization of a biodegradable scaffold. Human osteoblasts, cultured on silk fibroin micronets in vitro, migrated throughout the interconnected pores of the scaffold and produced extensive bone matrix. When these constructs we…
Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.
2008
We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.
Implant-supported overdenture with horizontal insertion for treating the edentulous atrophic maxilla: A case series
2020
Abstract Statement of problem Rehabilitation of edentulous patients with severe maxillary atrophy is a clinical challenge. Although several treatment options are available, the implant-supported overdenture has been widely advocated. However vertical insertion implant-supported overdentures have drawbacks, including wear, aging, and the continuous maintenance of retention systems. Whether an implant-supported overdenture with a horizontal insertion pathway can overcome these problems is unclear. Purpose The purpose of this observational study was to determine the clinical and biological behavior of a new type of implant-supported overdenture with a horizontal insertion pathway over a mean c…
In vitro optical performance of a new aberration-free intraocular lens
2014
To assess the optical performance of the new EnVista intraocular lens (IOL). Four aspheric IOLs were evaluated; the new EnVista is one amoung them. This IOL, similarly to the Z-Flex HB and the Bi-Flex 1.8 667AB ones, has a neutral aspheric design, whereas the fourth IOL under test (AcrySof IQ IOL SN60WF) presents a negative spherical aberration (SA). The IOL’s aberration patterns were measured in vitro, by setting them up on an optical bench. From these aberration-pattern data, the modulation transfer function (MTF), the average modulation values, and the points spread function (PSF) were calculated. Furthermore, in order to assess the potential optical quality that these IOLs would yield o…